Javascript must be enabled to continue!
The Heat Transfer and Fluid Flow Investigations of Single Dimple with Straight and Curved Arch Turbulator within in a Duct
View through CrossRef
An experimental study was conducted to examine the impact of a single dimple with an arch-type turbulator on heat transfer and fluid friction. The square duct has a 4:1 aspect ratio. Reynolds numbers range from 10,000 to 35,000 depending on hydraulic diameter, maintaining as 0.5 aspect ratio between duct height and dimple diameter. Dimple depth to print diameter ratio is 0.3, which is maintained constant. Two different types of arch turbulators are tested in the first half of the dimple to improve the fluid velocities and heat transfer. The turbulators used in the investigations are both curved and straight type. Curved arch turbulators included angles are 45°, 60°, or 90°, whereas straight arch turbulators are inclined to the surface at a 12° angle. At the dimple's leading edge, an arch turbulator is installed. The experimental findings are displayed as Nusselt number, normalized Nusselt number, friction factor, normalized friction factor, and thermal performance. According to the experimental findings, turbulators with a 60° curved arch operate better than those with 45° and 90° curved arches. Compared to all other arch turbulators, the straight arch turbulator achieves the highest thermal performance.
Title: The Heat Transfer and Fluid Flow Investigations of Single Dimple with Straight and Curved Arch Turbulator within in a Duct
Description:
An experimental study was conducted to examine the impact of a single dimple with an arch-type turbulator on heat transfer and fluid friction.
The square duct has a 4:1 aspect ratio.
Reynolds numbers range from 10,000 to 35,000 depending on hydraulic diameter, maintaining as 0.
5 aspect ratio between duct height and dimple diameter.
Dimple depth to print diameter ratio is 0.
3, which is maintained constant.
Two different types of arch turbulators are tested in the first half of the dimple to improve the fluid velocities and heat transfer.
The turbulators used in the investigations are both curved and straight type.
Curved arch turbulators included angles are 45°, 60°, or 90°, whereas straight arch turbulators are inclined to the surface at a 12° angle.
At the dimple's leading edge, an arch turbulator is installed.
The experimental findings are displayed as Nusselt number, normalized Nusselt number, friction factor, normalized friction factor, and thermal performance.
According to the experimental findings, turbulators with a 60° curved arch operate better than those with 45° and 90° curved arches.
Compared to all other arch turbulators, the straight arch turbulator achieves the highest thermal performance.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Flow Characteristics Within and Downstream of a Single Shallow Cylindrical and Spherical Dimple: Effect of Pre-Dimple Boundary Layer Thickness
Flow Characteristics Within and Downstream of a Single Shallow Cylindrical and Spherical Dimple: Effect of Pre-Dimple Boundary Layer Thickness
The objective of this study is to investigate the details of the average and unsteady flow structures in front, inside and after shallow (h/D = 0.1) spherical and cylindrical dimpl...
Presentation and Management of Cervical Thoracic Duct Cyst: A Systematic Review of the Literature
Presentation and Management of Cervical Thoracic Duct Cyst: A Systematic Review of the Literature
Abstract
Introduction
Thoracic duct cysts are an uncommon phenomenon, especially within the cervical region. Due to its limited reported cases, very little is known about its etiol...
A Numerical Study of the Flow and Heat Transfer in the Pin Fin-Dimple Channels With Various Dimple Depths
A Numerical Study of the Flow and Heat Transfer in the Pin Fin-Dimple Channels With Various Dimple Depths
A numerical study was conducted to investigate the effects of dimple depth on the flow and heat transfer characteristics in a pin fin-dimple channel, where dimples are located span...
Impact of Turbulator Design on the Heat Transfer in a High Aspect Ratio Passage of a Turbine Blade
Impact of Turbulator Design on the Heat Transfer in a High Aspect Ratio Passage of a Turbine Blade
The trailing edge region of gas turbine blades is generally subjected to extremely high external heat loads due to the combined effects of high mach numbers and gas temperatures. I...
Numerical investigation of dimple-texturing on the turning performance of hardened AISI H-13 steel
Numerical investigation of dimple-texturing on the turning performance of hardened AISI H-13 steel
Forming micro-dimples nearer to the cutting edge on the rack face of the tungsten carbide cutting inserts will positively influence the machinability. However, it is challenging to...
Isolated cystic duct cyst in a child :A case report
Isolated cystic duct cyst in a child :A case report
Abstract
Background:
Dilatation of the common bile duct is a common biliary malformation in children. However, isolated cysts of the cystic duct are extremely rare and not ...
Computational Analysis of Pulsating Pipe Flow for Heat and Flow Characteristics Enhancement
Computational Analysis of Pulsating Pipe Flow for Heat and Flow Characteristics Enhancement
To increase the performance of the thermal and flow devices with respect to the heat and flow characteristics in a pipe, different techniques are widely used such as modification i...

