Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Novel Determination of Anti-Hypertensive Combination; Benidipine Hydrochloride and Nebivolol Hydrochloride by High Performance Chromatographic Method

View through CrossRef
This research work was designed to establish and validate a novel stability indicating RP-HPLC method for the combined determination of Benidipine hydrochloride (BHE) and Nebivolol hydrochloride (NHE) in bulk and tablets, dependent on ICH guidelines.The assay method to analyse BHE and NHE was optimized with isocratic elution using acetonitrile: 0.1M acetate buffer (45:55, pH 5.1), Lichrospher ODS RP-18 column and flow pace of 1 ml/min. Total time for single run was 14 min. The injection quantity was 20μl, and was detected at 249nm. The method was verified on a concentration series of 1.25-10μg/ml (NHE) and 1.0-10μg/ml (BHE) for precision, accuracy and linearity. The LOD values were 0.059µg/ml and 0.028µg/ml for NHE and BHE, respectively. The LOQ values were 0.196µg/ml for NHE and 0.094µg/ml for BHE. The recovery percentages were 98.60-100.11% (BHE) and 98.94-101.50% (NHE) with relative standard deviation 0.250-0.694% (BHE) and 0.183-0.400% (NHE). The method was also observed to be efficient, and was sufficiently specific to measure BHE and NHE in the presence of stress-produced degradation products.
Title: Novel Determination of Anti-Hypertensive Combination; Benidipine Hydrochloride and Nebivolol Hydrochloride by High Performance Chromatographic Method
Description:
This research work was designed to establish and validate a novel stability indicating RP-HPLC method for the combined determination of Benidipine hydrochloride (BHE) and Nebivolol hydrochloride (NHE) in bulk and tablets, dependent on ICH guidelines.
The assay method to analyse BHE and NHE was optimized with isocratic elution using acetonitrile: 0.
1M acetate buffer (45:55, pH 5.
1), Lichrospher ODS RP-18 column and flow pace of 1 ml/min.
Total time for single run was 14 min.
The injection quantity was 20μl, and was detected at 249nm.
The method was verified on a concentration series of 1.
25-10μg/ml (NHE) and 1.
0-10μg/ml (BHE) for precision, accuracy and linearity.
The LOD values were 0.
059µg/ml and 0.
028µg/ml for NHE and BHE, respectively.
The LOQ values were 0.
196µg/ml for NHE and 0.
094µg/ml for BHE.
The recovery percentages were 98.
60-100.
11% (BHE) and 98.
94-101.
50% (NHE) with relative standard deviation 0.
250-0.
694% (BHE) and 0.
183-0.
400% (NHE).
The method was also observed to be efficient, and was sufficiently specific to measure BHE and NHE in the presence of stress-produced degradation products.

Related Results

Development and Validation of Analytical RP HPLC Method for Benidipine Hydrochloride
Development and Validation of Analytical RP HPLC Method for Benidipine Hydrochloride
The aim of the present study is development and validation of analytical reverse phase (RP) high performance liquid chromatography (HPLC) from Benidipine Hydrochloride. HPLC method...
Development and Evaluation of Self Micro Emulsifying Drug Delivery System (SMEDDS) for Nebivolol Hydrochloride
Development and Evaluation of Self Micro Emulsifying Drug Delivery System (SMEDDS) for Nebivolol Hydrochloride
The  present  investigation  aimed  to  prepare  a  self  micro  emulsifying  drug  delivery  system  (SMEDDS)  for  the dissolution enhancement of nebivolol hydrochloride.  The ma...
DESIGN AND EVALUATION OF LIQUISOLID COMPACTS OF NEBIVOLOL HYDROCHLORIDE
DESIGN AND EVALUATION OF LIQUISOLID COMPACTS OF NEBIVOLOL HYDROCHLORIDE
Objective: The aim of this study was to investigate the potential of a liquisolid system to improve the dissolution rate and the bioavailability of nebivolol hydrochloride. Methods...
HYPERTENSIVE CRISES: HYPERTENSIVE EMERGENCY AND CRISIS MANAGEMENT DURING ANESTHESIA
HYPERTENSIVE CRISES: HYPERTENSIVE EMERGENCY AND CRISIS MANAGEMENT DURING ANESTHESIA
Introduction: hypertensive crisis is characterized by an acute and massive increase in blood pressure. Hypertensive crises encompass several clinical situations with different seve...
Metabolic syndrome in hypertensive and non‐hypertensive subjects
Metabolic syndrome in hypertensive and non‐hypertensive subjects
AbstractBackground and aimsHypertension is a major risk factor of cardiovascular diseases (CVDs), which attributes to one‐third of all deaths worldwide. It is also considered as a ...
Pembrolizumab and Sarcoma: A meta-analysis
Pembrolizumab and Sarcoma: A meta-analysis
Abstract Introduction: Pembrolizumab is a monoclonal antibody that promotes antitumor immunity. This study presents a systematic review and meta-analysis of the efficacy and safety...
Both Carvedilol and Nebivolol May Improve Platelet Function and Prothrombotic State in Patients With Nonischemic Heart Failure
Both Carvedilol and Nebivolol May Improve Platelet Function and Prothrombotic State in Patients With Nonischemic Heart Failure
It is unclear whether carvedilol and nebivolol will produce different effects on platelet function and prothrombotic state in heart failure (HF). Thus, we compared their effects on...

Back to Top