Javascript must be enabled to continue!
Reliability of Weight-Bearing Ultrasonography for Diagnosis of Lisfranc Joint Injuries: A Cadaveric Study
View through CrossRef
Category:
Trauma
Introduction/Purpose:
Ultrasonography is increasingly used to evaluate the stability of various joint in the field of foot and ankle. This study aims to assess and compare the Lisfranc joint stability under stimulated weight bearing condition among progressive stages of Lisfranc ligamentous complex injuries. All the measurements were assessed using ultrasonography, fluoroscopy, and direct open measurement. We hypothesize that there is a correlation between ultrasonographic and fluoroscopic measurements, or between ultrasonographic and direct open measurements when performing stress evaluation of the Lisfranc instability.
Methods:
Twelve fresh below-knee amputated cadaveric specimens underwent ultrasound, fluoroscopic, and direct gross evaluation of the Lisfranc stability under simulated weight bearing condition. The assessment was first performed with all Lisfranc ligamentous complex intact and thereafter with sequential transection of the dorsal Lisfranc ligament, interosseous Lisfranc ligament, and plantar Lisfranc ligament. The simulated weight bearing condition was performed with 600N of force. The distances evaluated during the experimental set up were C1-M1, C2-M2, C1-M2, C1-C2 and M1-M2. All measurements were recorded in millimeter (mm). The ultrasound machine (GE, LOGIQ E-9 ultrasound machine, Chicago, Illinois, USA) was used to assess the Lisfranc stability by measuring the distances between the hyperechoic bone contours or the pre-defined landmark of the metatarsal and cuneiform bones. Correlations between 1) Ultrasound and fluoroscopic measurements, 2) Ultrasound and direct open measurements, and 3) Fluoroscopic and direct open measurements were evaluated using Pearson correlations coefficient.
Results:
Strong positive correlations between ultrasonographic and direct open measurements were found when assessed for C1-M1, C1-M2, C1-C2, M1-M2 (Pearson's correlation ranged from 0.73-0.97, p-values <0.001). Strong positive correlations between ultrasonographic and fluoroscopic measurements were found when assessed for C1-M1 from dorsal, medial, and plantar aspect (Pearson's correlation ranged from 0.75-0.90, p-values <0.001). Strong positive correlations between fluoroscopic and direct open measurements were found when assessed for C1-M1, C1-M2, C2-M2, M1-M2 (Pearson's correlation ranged from 0.77-0.93, p-values <0.001). Inter-rater and intra-rater reliability for the ultrasonographic measurements between the MSK radiologist (TK) and the foot and ankle surgeon (JS) were substantial (ICC ranged from 0.81-0.98).
Conclusion:
Ultrasonography is a reliable and reproducible tool for diagnosing Lisfranc ligamentous complex injuries. Both ultrasonographic and fluoroscopic measurements appear to strongly correlate with values measured by direct open measurement. Based on these data, ultrasonography is likely to become a valuable point of care diagnostic tool due to its ability to readily and dynamically evaluate suspected Lisfranc ligamentous complex injuries, without radiation exposure.
Title: Reliability of Weight-Bearing Ultrasonography for Diagnosis of Lisfranc Joint Injuries: A Cadaveric Study
Description:
Category:
Trauma
Introduction/Purpose:
Ultrasonography is increasingly used to evaluate the stability of various joint in the field of foot and ankle.
This study aims to assess and compare the Lisfranc joint stability under stimulated weight bearing condition among progressive stages of Lisfranc ligamentous complex injuries.
All the measurements were assessed using ultrasonography, fluoroscopy, and direct open measurement.
We hypothesize that there is a correlation between ultrasonographic and fluoroscopic measurements, or between ultrasonographic and direct open measurements when performing stress evaluation of the Lisfranc instability.
Methods:
Twelve fresh below-knee amputated cadaveric specimens underwent ultrasound, fluoroscopic, and direct gross evaluation of the Lisfranc stability under simulated weight bearing condition.
The assessment was first performed with all Lisfranc ligamentous complex intact and thereafter with sequential transection of the dorsal Lisfranc ligament, interosseous Lisfranc ligament, and plantar Lisfranc ligament.
The simulated weight bearing condition was performed with 600N of force.
The distances evaluated during the experimental set up were C1-M1, C2-M2, C1-M2, C1-C2 and M1-M2.
All measurements were recorded in millimeter (mm).
The ultrasound machine (GE, LOGIQ E-9 ultrasound machine, Chicago, Illinois, USA) was used to assess the Lisfranc stability by measuring the distances between the hyperechoic bone contours or the pre-defined landmark of the metatarsal and cuneiform bones.
Correlations between 1) Ultrasound and fluoroscopic measurements, 2) Ultrasound and direct open measurements, and 3) Fluoroscopic and direct open measurements were evaluated using Pearson correlations coefficient.
Results:
Strong positive correlations between ultrasonographic and direct open measurements were found when assessed for C1-M1, C1-M2, C1-C2, M1-M2 (Pearson's correlation ranged from 0.
73-0.
97, p-values <0.
001).
Strong positive correlations between ultrasonographic and fluoroscopic measurements were found when assessed for C1-M1 from dorsal, medial, and plantar aspect (Pearson's correlation ranged from 0.
75-0.
90, p-values <0.
001).
Strong positive correlations between fluoroscopic and direct open measurements were found when assessed for C1-M1, C1-M2, C2-M2, M1-M2 (Pearson's correlation ranged from 0.
77-0.
93, p-values <0.
001).
Inter-rater and intra-rater reliability for the ultrasonographic measurements between the MSK radiologist (TK) and the foot and ankle surgeon (JS) were substantial (ICC ranged from 0.
81-0.
98).
Conclusion:
Ultrasonography is a reliable and reproducible tool for diagnosing Lisfranc ligamentous complex injuries.
Both ultrasonographic and fluoroscopic measurements appear to strongly correlate with values measured by direct open measurement.
Based on these data, ultrasonography is likely to become a valuable point of care diagnostic tool due to its ability to readily and dynamically evaluate suspected Lisfranc ligamentous complex injuries, without radiation exposure.
Related Results
Lisfranc Joint Injury: A Comprehensive Review of Rehabilitation Duration in Basketball Athletes
Lisfranc Joint Injury: A Comprehensive Review of Rehabilitation Duration in Basketball Athletes
Introduction
Lisfranc injuries, characterized by abnormal forces on the tarsometatarsal (TMT) joints in the feet, are common foot injuries in athletes. This stu...
Morphological characteristics of the Lisfranc ligament
Morphological characteristics of the Lisfranc ligament
Abstract
Background
This study aimed to clarify the morphological characteristics of the Lisfranc ligament and the plantar ligament.
Methods
Forty legs from 20 cadavers w...
Short-term Follow-up of Patients Receiving Bio-integrative Screws for Lisfranc Injuries: A Case Series
Short-term Follow-up of Patients Receiving Bio-integrative Screws for Lisfranc Injuries: A Case Series
Introduction: Various methods are used for open reduction and internal fixation of Lisfranc injuries, and each shows different post-treatment outcomes. Other than the common post-s...
Clinical Outcomes after ORIF vs Arthrodesis for Subtle Lisfranc Injuries: A Minimum 2-Year Comparative Study
Clinical Outcomes after ORIF vs Arthrodesis for Subtle Lisfranc Injuries: A Minimum 2-Year Comparative Study
Background:
Subtle Lisfranc injuries, defined by 2-5 mm of first webspace diastasis, pose unique treatment challenges distinct from more severe injuries. This study aim...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Reliability of Weight-Bearing Ultrasonography for Assessment of Sesamoid Position and Rotation: A Cadaveric Study
Reliability of Weight-Bearing Ultrasonography for Assessment of Sesamoid Position and Rotation: A Cadaveric Study
Category:
Midfoot/Forefoot; Bunion
Introduction/Purpose:
Ultrasonography is increa...
Domination of Polynomial with Application
Domination of Polynomial with Application
In this paper, .We .initiate the study of domination. polynomial , consider G=(V,E) be a simple, finite, and directed graph without. isolated. vertex .We present a study of the Ira...
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Background:
Primarily ligamentous Lisfranc injuries occur in athletic populations. Unstable Lisfranc injuries are treated with internal fixation or arthrodesis. Interna...