Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Galvanised constructional elements in contact with prestressing steel tendons

View through CrossRef
AbstractIn order to clarify under which practical conditions real risks for hydrogen‐induced stress corrosion cracking of prestressing steels exist laboratory investigations in aqueous solutions and concrete as well as tests with stressed prestressing steels were carried out. While different distances between steel and zinc (cathode and anode) showed only a negligible influence on the polarisation of the steel a significant dependence on the area ratio steel/zinc was observed. A critical area ratio of 10:1 can be defined above which polarisation of the steel to hydrogen evolution potentials is unlikely. The results obtained in the laboratory concerning the critical area ratio were confirmed by on‐site investigations in a precasting plant. Exposure tests with hydrogen loading did not lead to fractures during the testing time for approved prestressing steels. The characteristic mechanical values determined immediately after the hydrogen loading tests did not show significant changes. Thus, an indirect contact between prestressing steels and galvanised elements can be estimated as uncritical. But a direct contact has to be excluded by compliance with DIN 1045‐1, i.e minimal distance of 2 cm between prestressing steel and galvanised elements.
Title: Galvanised constructional elements in contact with prestressing steel tendons
Description:
AbstractIn order to clarify under which practical conditions real risks for hydrogen‐induced stress corrosion cracking of prestressing steels exist laboratory investigations in aqueous solutions and concrete as well as tests with stressed prestressing steels were carried out.
While different distances between steel and zinc (cathode and anode) showed only a negligible influence on the polarisation of the steel a significant dependence on the area ratio steel/zinc was observed.
A critical area ratio of 10:1 can be defined above which polarisation of the steel to hydrogen evolution potentials is unlikely.
The results obtained in the laboratory concerning the critical area ratio were confirmed by on‐site investigations in a precasting plant.
Exposure tests with hydrogen loading did not lead to fractures during the testing time for approved prestressing steels.
The characteristic mechanical values determined immediately after the hydrogen loading tests did not show significant changes.
Thus, an indirect contact between prestressing steels and galvanised elements can be estimated as uncritical.
But a direct contact has to be excluded by compliance with DIN 1045‐1, i.
e minimal distance of 2 cm between prestressing steel and galvanised elements.

Related Results

Research and Development of a Three-Piece Tendon for a TLP
Research and Development of a Three-Piece Tendon for a TLP
Abstract Research and development of TLP tendon is described. Forged tendons are in actual use but their cost increases rapidly as the diameter becomes greater. ...
Analysis of the Condition of Tendons in Prestressed Concrete Structures
Analysis of the Condition of Tendons in Prestressed Concrete Structures
Prestressing Steel Fracture Detection Bernd Hillemeier, Simon Knapp, Thomas Luther Abstract The earliest possible non-destructive location of a prestressing steel fracture is a...
Carbon Fiber Composite Tendons for Deepwater Tension Leg Platforms
Carbon Fiber Composite Tendons for Deepwater Tension Leg Platforms
Abstract The paper presents new technology for the tendons of deepwater Tension Leg Platforms (TLPs) based on Carbon Fiber Composites. The technology, named 3C-Te...
Research on in situ recovery technology of hot-dip galvanised dross
Research on in situ recovery technology of hot-dip galvanised dross
The hot-dip galvanising industry is the largest consumer of zinc, with over 40 per cent of the world’s total annual production of zinc used for galvanised steel. The dross generate...
Constructional network at work in second language acquisition
Constructional network at work in second language acquisition
AbstractSecond Language Acquisition (SLA) has benefited quite a lot from Construction Grammar. Most of the previous SLA researches adopting a constructionist approach have been pri...
Corrosion Fatigue of Heavy-Duty Coated and Cathodically Protected Steel for TLP Tendons
Corrosion Fatigue of Heavy-Duty Coated and Cathodically Protected Steel for TLP Tendons
ABSTRACT Fatigue properties of 80 ksi yield strength level steel in seawater treated with the combined protection system, which consists of a heavy-duty double-la...
Evaluation of the Effect of Temperature (20–700 °C) on the Properties of Prestressing Steel Using AE Signals and FEM Analysis
Evaluation of the Effect of Temperature (20–700 °C) on the Properties of Prestressing Steel Using AE Signals and FEM Analysis
The study presents a comprehensive analysis of the effects of high temperatures (500 °C and 700 °C) on the microstructure, mechanical properties, and acoustic emission (AE) paramet...
Constructional Gradience
Constructional Gradience
Abstract In this chapter I will discuss gradience obtaining either within a particular construction-type (Subsective Constructional Gradience) or between two differe...

Back to Top