An optical switch based on an electrowetting prism coupled to a multimode fiber has demonstrated a large extinction ratio with speeds up to 300 Hz. Electrowetting prisms provide a transmissive, low power, and compact alternative to conventional free-space optical switches, with no moving parts. The electrowetting prism performs beam steering of ±3° with an extinction ratio of 47 dB between the ON and OFF states and has been experimentally demonstrated at scanning frequencies of 100–300 Hz. The optical design is modeled in Zemax to account for secondary rays created at each surface interface (without scattering). Simulations predict 50 dB of extinction, in good agreement with experiment.
Optica Publishing Group
Title: High extinction ratio, low insertion loss, optical switch based on an electrowetting prism
Description:
An optical switch based on an electrowetting prism coupled to a multimode fiber has demonstrated a large extinction ratio with speeds up to 300 Hz.
Electrowetting prisms provide a transmissive, low power, and compact alternative to conventional free-space optical switches, with no moving parts.
The electrowetting prism performs beam steering of ±3° with an extinction ratio of 47 dB between the ON and OFF states and has been experimentally demonstrated at scanning frequencies of 100–300 Hz.
The optical design is modeled in Zemax to account for secondary rays created at each surface interface (without scattering).
Simulations predict 50 dB of extinction, in good agreement with experiment.
Related Results
Contactless electrowetting
Contactless electrowetting
Electrowetting technology, known since more than 100 years, just recently was successfully applied for the fabrication of devices such as pixels, liquid lenses and µTas (micro tota...
#1089 Outcomes of medical and surgical peritoneal dialysis catheter insertion: a single centre experience
#1089 Outcomes of medical and surgical peritoneal dialysis catheter insertion: a single centre experience
Abstract
Background and Aims
Medical insertion of peritoneal dialysis (PD) catheters has been common practice within the ...
The Account of the Effect of Switch Probability on Switch and Mixing Costs: An ERP Study in a Cued Task-switching Paradigm
The Account of the Effect of Switch Probability on Switch and Mixing Costs: An ERP Study in a Cued Task-switching Paradigm
Background:
Whether the effect of switch probability on switch and mixing costs is explained by an activation or preparation account is unclear.
...
Infralimbic projections to the basal forebrain mediate extinction learning
Infralimbic projections to the basal forebrain mediate extinction learning
Abstract
Fear extinction learning and retrieval are critical for decreasing fear responses to a stimulus that no longer poses a threat. While it ...
We might not notice a 'mass' extinction
We might not notice a 'mass' extinction
Background
There is overwhelming evidence that global change is having widespread, detrimental impacts on biodiversity. Population declines and local disappearances have been recor...
Human Extinction from Natural Hazard Events
Human Extinction from Natural Hazard Events
Like any other species, Homo sapiens can potentially go extinct. This risk is an existential risk: a threat to the entire future of the species (and possible descendants). While an...
Circadian Rhythms in Fear Extinction Recall Depend on the Time of Day of Extinction Recall, Not the Time of Day of Extinction Learning
Circadian Rhythms in Fear Extinction Recall Depend on the Time of Day of Extinction Recall, Not the Time of Day of Extinction Learning
The recall of conditioned fear extinction exhibits a circadian rhythm in humans and rodents, with optimal extinction recall occurring during the early active phase. However, it rem...
Safety and efficacy of laryngeal mask airway placement in term of oropharyngeal leak pressure: A comparison between conventional insertion and laryngoscope guided insertion
Safety and efficacy of laryngeal mask airway placement in term of oropharyngeal leak pressure: A comparison between conventional insertion and laryngoscope guided insertion
Background: The effectiveness of laryngeal mask airway (LMA) through conventional insertion technique versus laryngoscope-guided insertion is a debatable issue. Use of only fiberop...