Comparison of 5 and 10 Storey Frame Buildings and 5 and 10 Storey Shear Wall-Frame Buildings Under the Effect of Maras Earthquake According to the Turkish Building Earthquake Code 2018
View through CrossRef
In this study, the differences in the displacements, base shear forces, relative storey drifts and foundation stresses under different earthquake data on different storeys of shear wall frame systems and framed systems are investigated by using SAP2000 program. Within the scope of the study, four buildings with 5-storey frame, 5-storey shear wall frame, 10-storey frame and 10 storey shear wall frame are modelled. All four buildings were designed to be identical with 4 spans in X and Y directions and each span was designed as 5 meters. The height of each floor is designed as 3 meters for all four buildings. In sheared structures, shear walls are designed to be 4 meters from the corner columns to the columns closest to them. The earthquake data to be influenced on all four structures are the earthquake data from the Earthquake Hazard Map of Turkey published by AFAD at the coordinates of 41° latitude, 27° longitude of Kırklareli province, Luleburgaz district. Another earthquake parameter was taken from station 4615 during the earthquake in Kahramanmaras. The data recorded by station 4615 for the 7.6 Mw earthquake in Kahramanmaras was applied to all four structures. These two earthquake data were imposed on these four structures in order to compare the resulting displacements, relative storey drifts, base shear forces and foundation stresses. Since the structures are all symmetrical in both X and Y directions, only one direction of the displacements was calculated. As a result, when both the earthquake data from the Earthquake Hazard Map and the Kahramanmaras earthquake data were applied to these four structures, it was observed that the maximum values of the displacements occurred at the top floors of all structures and the effect of the Kahramanmaras earthquake data was higher in the displacements, relative storey drifts, base shear forces and foundation stresses than the effect of the other earthquake data.
Scienceline Publication
Title: Comparison of 5 and 10 Storey Frame Buildings and 5 and 10 Storey Shear Wall-Frame Buildings Under the Effect of Maras Earthquake According to the Turkish Building Earthquake Code 2018
Description:
In this study, the differences in the displacements, base shear forces, relative storey drifts and foundation stresses under different earthquake data on different storeys of shear wall frame systems and framed systems are investigated by using SAP2000 program.
Within the scope of the study, four buildings with 5-storey frame, 5-storey shear wall frame, 10-storey frame and 10 storey shear wall frame are modelled.
All four buildings were designed to be identical with 4 spans in X and Y directions and each span was designed as 5 meters.
The height of each floor is designed as 3 meters for all four buildings.
In sheared structures, shear walls are designed to be 4 meters from the corner columns to the columns closest to them.
The earthquake data to be influenced on all four structures are the earthquake data from the Earthquake Hazard Map of Turkey published by AFAD at the coordinates of 41° latitude, 27° longitude of Kırklareli province, Luleburgaz district.
Another earthquake parameter was taken from station 4615 during the earthquake in Kahramanmaras.
The data recorded by station 4615 for the 7.
6 Mw earthquake in Kahramanmaras was applied to all four structures.
These two earthquake data were imposed on these four structures in order to compare the resulting displacements, relative storey drifts, base shear forces and foundation stresses.
Since the structures are all symmetrical in both X and Y directions, only one direction of the displacements was calculated.
As a result, when both the earthquake data from the Earthquake Hazard Map and the Kahramanmaras earthquake data were applied to these four structures, it was observed that the maximum values of the displacements occurred at the top floors of all structures and the effect of the Kahramanmaras earthquake data was higher in the displacements, relative storey drifts, base shear forces and foundation stresses than the effect of the other earthquake data.
Related Results
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
A Comparison of Rusunawa A4 IPB Building Storey Shear using Seismic Code of SNI 1726-2002 and SNI 1726-2012
A Comparison of Rusunawa A4 IPB Building Storey Shear using Seismic Code of SNI 1726-2002 and SNI 1726-2012
Indonesia is a high-risk earthquake country. It passed by Pacific Ring of Fire and surrounded by Eurasian, Pacific, Philippines and Indo-Australian plates. Indonesia government has...
Der skal ikke lades sten på sten tilbage
Der skal ikke lades sten på sten tilbage
The Building by the Barbar TempleClose by the large temple at Barbar 1) lies a little tell, which was investigated in the spring of 1956. The tell was shown to cover a building of ...
Optimum Location of Soft Storey in Multi-Storeyed Building
Optimum Location of Soft Storey in Multi-Storeyed Building
The present study is focus on 11-storey reinforced concrete buildings to optimize the location of soft storey under seismic zone-v. The plan of building 40m x 40m is considered. In...
Effect of Aspect Ratio on High Rise Structures with Diagrid
Effect of Aspect Ratio on High Rise Structures with Diagrid
Urbanization and population explosion in the present times has led to increase in demand for land and residencies but the availability of land is scare i.e reason a trend has evolv...
Seismic Analysis of Horizontal and Vertical Irregular RC Multi Storey Building With Effect of Opening in Shear Wall
Seismic Analysis of Horizontal and Vertical Irregular RC Multi Storey Building With Effect of Opening in Shear Wall
At present days building a structure with all the regular configurations is not feasible in most of the cases due to the irregular plot dimensions, aesthetic visual and functional ...
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Magnetoelectric (ME) composites have recently attracted much attention and triggered a great number of research activities, owing to their potential applications in sensors and tra...
Analisis Struktur Beton Bertulang Tahan Gempa Untuk Berbagai Variasi Tinggi Bangunan
Analisis Struktur Beton Bertulang Tahan Gempa Untuk Berbagai Variasi Tinggi Bangunan
Indonesia is a country prone to earthquakes because it is located at the confluence of the Pacific and Trans-Asiatic Circum. Padang is included in the 5-6 earthquake area (KDS E &a...