AARC Clinical Practice Guideline: Patient-Ventilator Assessment
View through CrossRef
Given the important role of patient-ventilator assessments in ensuring the safety and efficacy of mechanical ventilation, a team of respiratory therapists and a librarian used Grading of Recommendations, Assessment, Development, and Evaluation methodology to make the following recommendations: (1) We recommend assessment of plateau pressure to ensure lung-protective ventilator settings (strong recommendation, high certainty); (2) We recommend an assessment of tidal volume (V
T
) to ensure lung-protective ventilation (4–8 mL/kg/predicted body weight) (strong recommendation, high certainty); (3) We recommend documenting V
T
as mL/kg predicted body weight (strong recommendation, high certainty); (4) We recommend an assessment of PEEP and auto-PEEP (strong recommendation, high certainty); (5) We suggest assessing driving pressure to prevent ventilator-induced injury (conditional recommendation, low certainty); (6) We suggest assessing F
IO
2
to ensure normoxemia (conditional recommendation, very low certainty); (7) We suggest telemonitoring to supplement direct bedside assessment in settings with limited resources (conditional recommendation, low certainty); (8) We suggest direct bedside assessment rather than telemonitoring when resources are adequate (conditional recommendation, low certainty); (9) We suggest assessing adequate humidification for patients receiving noninvasive ventilation (NIV) and invasive mechanical ventilation (conditional recommendation, very low certainty); (10) We suggest assessing the appropriateness of the humidification device during NIV and invasive mechanical ventilation (conditional recommendation, low certainty); (11) We recommend that the skin surrounding artificial airways and NIV interfaces be assessed (strong recommendation, high certainty); (12) We suggest assessing the dressing used for tracheostomy tubes and NIV interfaces (conditional recommendation, low certainty); (13) We recommend assessing the pressure inside the cuff of artificial airways using a manometer (strong recommendation, high certainty); (14) We recommend that continuous cuff pressure assessment should not be implemented to decrease the risk of ventilator-associated pneumonia (strong recommendation, high certainty); and (15) We suggest assessing the proper placement and securement of artificial airways (conditional recommendation, very low certainty).
Title: AARC Clinical Practice Guideline: Patient-Ventilator Assessment
Description:
Given the important role of patient-ventilator assessments in ensuring the safety and efficacy of mechanical ventilation, a team of respiratory therapists and a librarian used Grading of Recommendations, Assessment, Development, and Evaluation methodology to make the following recommendations: (1) We recommend assessment of plateau pressure to ensure lung-protective ventilator settings (strong recommendation, high certainty); (2) We recommend an assessment of tidal volume (V
T
) to ensure lung-protective ventilation (4–8 mL/kg/predicted body weight) (strong recommendation, high certainty); (3) We recommend documenting V
T
as mL/kg predicted body weight (strong recommendation, high certainty); (4) We recommend an assessment of PEEP and auto-PEEP (strong recommendation, high certainty); (5) We suggest assessing driving pressure to prevent ventilator-induced injury (conditional recommendation, low certainty); (6) We suggest assessing F
IO
2
to ensure normoxemia (conditional recommendation, very low certainty); (7) We suggest telemonitoring to supplement direct bedside assessment in settings with limited resources (conditional recommendation, low certainty); (8) We suggest direct bedside assessment rather than telemonitoring when resources are adequate (conditional recommendation, low certainty); (9) We suggest assessing adequate humidification for patients receiving noninvasive ventilation (NIV) and invasive mechanical ventilation (conditional recommendation, very low certainty); (10) We suggest assessing the appropriateness of the humidification device during NIV and invasive mechanical ventilation (conditional recommendation, low certainty); (11) We recommend that the skin surrounding artificial airways and NIV interfaces be assessed (strong recommendation, high certainty); (12) We suggest assessing the dressing used for tracheostomy tubes and NIV interfaces (conditional recommendation, low certainty); (13) We recommend assessing the pressure inside the cuff of artificial airways using a manometer (strong recommendation, high certainty); (14) We recommend that continuous cuff pressure assessment should not be implemented to decrease the risk of ventilator-associated pneumonia (strong recommendation, high certainty); and (15) We suggest assessing the proper placement and securement of artificial airways (conditional recommendation, very low certainty).
Related Results
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
Us Public Health Service Clinical Practice Guideline: Treating Tobacco Use and Dependence
Us Public Health Service Clinical Practice Guideline: Treating Tobacco Use and Dependence
Treating Tobacco Use and Dependence, a Public Health Service-sponsored Clinical Practice Guideline, is a product of the Tobacco Use and Dependence Guideline Panel ("the panel"), co...
Adaptive split ventilator system enables parallel ventilation, individual monitoring and ventilation pressures control for each lung simulators
Adaptive split ventilator system enables parallel ventilation, individual monitoring and ventilation pressures control for each lung simulators
Abstract
Objective
In mass crisis setting such as the COVID-19 pandemic, the number of patients requiring ...
Critical care nurses' knowledge and attitudes toward using ventilator waveform monitoring to detect patient-ventilator asynchrony: A cross-sectional online survey
Critical care nurses' knowledge and attitudes toward using ventilator waveform monitoring to detect patient-ventilator asynchrony: A cross-sectional online survey
Abstract
Background
Most mechanically ventilated patients will be exposed to some asynchrony with the ventilator. Inability to detect and manage patient-ventilator asynchr...
Performance of the Oxylog® 1000 portable ventilator in a hyperbaric environment
Performance of the Oxylog® 1000 portable ventilator in a hyperbaric environment
Introduction: The management of mechanically ventilated patients in the hyperbaric environment requires knowledge of how the physical properties of gases change under pressure and ...
Efficacy of compliance with ventilator-associated pneumonia care bundle: A 24-month longitudinal study at Bach Mai Hospital, Vietnam
Efficacy of compliance with ventilator-associated pneumonia care bundle: A 24-month longitudinal study at Bach Mai Hospital, Vietnam
Introduction:
To decrease the risk of complications from ventilator-associated pneumonia, it is essential to implement preventative measures in all ICU patients...
<b>EFFECTIVENESS OF CONTINUOUS SURVEILLANCE ON REDUCING VENTILATOR-ASSOCIATED PNEUMONIA RATES IN THE INTENSIVE CARE UNIT OF MEDICARE HOSPITAL MULTAN</b>
<b>EFFECTIVENESS OF CONTINUOUS SURVEILLANCE ON REDUCING VENTILATOR-ASSOCIATED PNEUMONIA RATES IN THE INTENSIVE CARE UNIT OF MEDICARE HOSPITAL MULTAN</b>
Background: Ventilator-associated pneumonia (VAP) is a leading cause of morbidity and mortality in intensive care units (ICUs) worldwide, with disproportionately high rates reporte...
Interview: Kari Tikkinen
Interview: Kari Tikkinen
What initially sparked your interest in medicine, and what led you specifically to the field of urology?
I was not sure about medicine until I was almost 20. In high school I was t...