New Data on Grouted Connections With Large Grout Dimensions

View through CrossRef
ABSTRACT The paper describes two studies into the static strength of grouted connections with low D/T ratios. These were performed as part of the development programme for the North Rankin 'A' foundation improvements. One study was on the strength of grouted pile plugs in 1.83m diameter piles and comprised tests on quarter scale and full size pile sections. The other study comprised quarter scale tests on pile/insert connections where both steel tubulars and the grout annulus had low D/T ratios; the effect of different weld bead shear connector geometries was also studied. The new data presented is complimentary to existing design guidance on the strength of grouted connections, and extends the available data into connection geometries with large grout dimensions. The results of tests on four quarter scale and two full size pile plug specimens are presented, together with the results of tests on a further ten quarter scale pile/insert specimens with different weld bead shear connector geometries, different grout types and loading arrangements. Comparison is made with the predicted strengths derived from current UK and US design guidance. The tests demonstrate that current design guidance formulae for grouted connections cannot be extrapolated to connection with tubular and grout annulus diameter to thickness ratios below the recommended lower limits of applicability if current safety margins are to be maintained. INTRODUCTION Design formulae for grouted connections are recommended by both the UK Department of Energy(1) and API(2). Both recommendations impose limits on connection geometry because of the limited extent of the test data available. Remedial measures to improve the performance of the piles foundations to the North Rankin 'A' platform used grouted connections of two different types. First, grout plugs were constructed over the bottom 15m of each of the 32 No. 1.83m diameter driven piles as a temporary measure to improve their end bearing capacity. Second, a conventional pile/sleeve type connection was used to transfer load from the driven piles to the under-reamed pile bells via an insert tubular. Few data are available on the strength of pile grout plugs, particularly so for the North Rankin 'A' plugs which were constructed of a blast furnace cement grout to reduce the risk of thermal cracking. Because of the nature of the existing piles and the proposed insert to transfer load from pile to bell, design of the pile/insert connection fell outside the design guidance provided by the UK Department of Energy. For these reasons model testing was carried out to:determine the capacity of the pile plugs, andprovide data for the design of the pile/insert connection. DESIGN OF GROUTED CONNECTIONS Pile Plugs Design can be based on a simple bond/shear approach assuming all load is transferred from pile to plug through the pile/grout interface or the weld bead hear connection.
Title: New Data on Grouted Connections With Large Grout Dimensions
Description:
ABSTRACT The paper describes two studies into the static strength of grouted connections with low D/T ratios.
These were performed as part of the development programme for the North Rankin 'A' foundation improvements.
One study was on the strength of grouted pile plugs in 1.
83m diameter piles and comprised tests on quarter scale and full size pile sections.
The other study comprised quarter scale tests on pile/insert connections where both steel tubulars and the grout annulus had low D/T ratios; the effect of different weld bead shear connector geometries was also studied.
The new data presented is complimentary to existing design guidance on the strength of grouted connections, and extends the available data into connection geometries with large grout dimensions.
The results of tests on four quarter scale and two full size pile plug specimens are presented, together with the results of tests on a further ten quarter scale pile/insert specimens with different weld bead shear connector geometries, different grout types and loading arrangements.
Comparison is made with the predicted strengths derived from current UK and US design guidance.
The tests demonstrate that current design guidance formulae for grouted connections cannot be extrapolated to connection with tubular and grout annulus diameter to thickness ratios below the recommended lower limits of applicability if current safety margins are to be maintained.
INTRODUCTION Design formulae for grouted connections are recommended by both the UK Department of Energy(1) and API(2).
Both recommendations impose limits on connection geometry because of the limited extent of the test data available.
Remedial measures to improve the performance of the piles foundations to the North Rankin 'A' platform used grouted connections of two different types.
First, grout plugs were constructed over the bottom 15m of each of the 32 No.
1.
83m diameter driven piles as a temporary measure to improve their end bearing capacity.
Second, a conventional pile/sleeve type connection was used to transfer load from the driven piles to the under-reamed pile bells via an insert tubular.
Few data are available on the strength of pile grout plugs, particularly so for the North Rankin 'A' plugs which were constructed of a blast furnace cement grout to reduce the risk of thermal cracking.
Because of the nature of the existing piles and the proposed insert to transfer load from pile to bell, design of the pile/insert connection fell outside the design guidance provided by the UK Department of Energy.
For these reasons model testing was carried out to:determine the capacity of the pile plugs, andprovide data for the design of the pile/insert connection.
DESIGN OF GROUTED CONNECTIONS Pile Plugs Design can be based on a simple bond/shear approach assuming all load is transferred from pile to plug through the pile/grout interface or the weld bead hear connection.

Related Results

Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Grouted Pile-to-Sleeve Connection Tests
Grouted Pile-to-Sleeve Connection Tests
ABSTRACT Eighteen grouted pile-sleeve connections were tested to examine the influence of combined loading (moment and axial load), relative shear key location be...
The Properties of Masonry Grout in Concrete Masonry
The Properties of Masonry Grout in Concrete Masonry
This paper presents the results of a research project on the properties of masonry grout and grouted concrete masonry. Seventy-two grout specimens were tested to investigate the ef...
Assessment of Post-Tensioned Grout Durability by Accelerated Robustness and Corrosion Testing
Assessment of Post-Tensioned Grout Durability by Accelerated Robustness and Corrosion Testing
The corrosion of steel in post-tensioned tendons has been associated with deficient grout materials containing high free sulfate ion concentrations. In a Florida bridge in 2011, te...
Integrity Testing of Three Drilled and Grouted Piles
Integrity Testing of Three Drilled and Grouted Piles
THE PROJECT The work described in this article was done to evaluate the ability of oil field grout logging technology to determ1ne the integrity of drilled and gr...
Corrosion of Post-Tensioned Tendons with Deficient Grout, Part 3: Segregated Grout with Elevated Sulfate and Vestigial Chloride Content
Corrosion of Post-Tensioned Tendons with Deficient Grout, Part 3: Segregated Grout with Elevated Sulfate and Vestigial Chloride Content
Severe corrosion of post-tensioned (PT) tendons with pre-packaged thixotropic grout was documented in Florida bridges after less than 8 years of service. In those bridges, corrosio...
Grouted Piles in Weak Carbonate Rocks
Grouted Piles in Weak Carbonate Rocks
ABSTRACT This paper describes a proposed method of design for the axial capacity of grouted piles in weak carbonate rocks. The, method was developed during a deta...
New API Equation for Grouted Pile-to-Structure Connections
New API Equation for Grouted Pile-to-Structure Connections
ABSTRACT A new equation for the design of axial load transfer in grouted pile-to-structure connections, with or without shear keys, has been written into the late...

Back to Top