Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluation of six commercial and in-house phenotypic tests for detection of AmpC β-lactamases: is routine detection possible?

View through CrossRef
Abstract Background Phenotypic characterization of the prevalent AmpC β-lactamases in clinical isolates is essential for making informed empirical decisions and critical for strengthening antimicrobial stewardship programmes. This study focused on assessing six assays, two in-house and four commercial phenotypic tests for detection of AmpC, to study the feasibility of making its detection a routine diagnostic microbiology laboratory activity. Methods A total of 116 non-duplicate Gram-negative bacteria that were resistant to third-generation cephalosporins and amoxicillin/clavulanic acid, and resistant or susceptible to piperacillin/tazobactam and carbapenems, were screened by cefoxitin discs for AmpC. These isolates were subjected to two in-house (AmpC Tris-EDTA and disc approximation) methods and four commercial tests: D69C AmpC Detection Set; D72C ESBL, AmpC & Carbapenemase Detection Set; combination disc test: ESBL + AmpC Screen Disc Kit; and AmpC MIC Test Strip for confirmation of AmpC production. Ten whole-genome-sequenced AmpC-confirmed Gram-negative isolates were used as positive controls and one as a negative control. Results The prevalence of AmpC β-lactamases was 16%. Escherichia coli was a major carrier of plasmid-mediated AmpC (26.5%), followed by Klebsiella pneumoniae (23.4%). Phenotypically, 61% of AmpCs were detected by Tris-EDTA (accuracy: 73.8%), 76% by disc approximation (accuracy: 89.2%), 75% by the D69C AmpC Detection Set (accuracy: 95.4%), 74% by the D72C AmpC, ESBL & Carbapenemase Detection Set (accuracy: 95.4%), 76% by the combination disc test (accuracy: 95.4%) and 63% by AmpC MIC Test Strip (accuracy: 87.7%). The sensitivity and specificity of D69C were 97.9% and 88.2%, respectively, and 95.9% and 93.8% for the combination disc test, while for the disc approximation test and D72C they were 93.9% and 75%, and 93.9% and 100%, respectively. Screening by cefoxitin screening was less sensitive (75%) and specific (25%). Disc approximation and the combination disc test detect AmpC in Enterobacterales and also Pseudomonas aeruginosa and Acinetobacter species. Conclusions We recommend the in-house disc approximation test and the commercial D69C, as well as the combination disc test, as excellent tools for detection of AmpC. The cefoxitin test overcalls AmpC and cannot be considered a good stand-alone test for AmpC detection.
Title: Evaluation of six commercial and in-house phenotypic tests for detection of AmpC β-lactamases: is routine detection possible?
Description:
Abstract Background Phenotypic characterization of the prevalent AmpC β-lactamases in clinical isolates is essential for making informed empirical decisions and critical for strengthening antimicrobial stewardship programmes.
This study focused on assessing six assays, two in-house and four commercial phenotypic tests for detection of AmpC, to study the feasibility of making its detection a routine diagnostic microbiology laboratory activity.
Methods A total of 116 non-duplicate Gram-negative bacteria that were resistant to third-generation cephalosporins and amoxicillin/clavulanic acid, and resistant or susceptible to piperacillin/tazobactam and carbapenems, were screened by cefoxitin discs for AmpC.
These isolates were subjected to two in-house (AmpC Tris-EDTA and disc approximation) methods and four commercial tests: D69C AmpC Detection Set; D72C ESBL, AmpC & Carbapenemase Detection Set; combination disc test: ESBL + AmpC Screen Disc Kit; and AmpC MIC Test Strip for confirmation of AmpC production.
Ten whole-genome-sequenced AmpC-confirmed Gram-negative isolates were used as positive controls and one as a negative control.
Results The prevalence of AmpC β-lactamases was 16%.
Escherichia coli was a major carrier of plasmid-mediated AmpC (26.
5%), followed by Klebsiella pneumoniae (23.
4%).
Phenotypically, 61% of AmpCs were detected by Tris-EDTA (accuracy: 73.
8%), 76% by disc approximation (accuracy: 89.
2%), 75% by the D69C AmpC Detection Set (accuracy: 95.
4%), 74% by the D72C AmpC, ESBL & Carbapenemase Detection Set (accuracy: 95.
4%), 76% by the combination disc test (accuracy: 95.
4%) and 63% by AmpC MIC Test Strip (accuracy: 87.
7%).
The sensitivity and specificity of D69C were 97.
9% and 88.
2%, respectively, and 95.
9% and 93.
8% for the combination disc test, while for the disc approximation test and D72C they were 93.
9% and 75%, and 93.
9% and 100%, respectively.
Screening by cefoxitin screening was less sensitive (75%) and specific (25%).
Disc approximation and the combination disc test detect AmpC in Enterobacterales and also Pseudomonas aeruginosa and Acinetobacter species.
Conclusions We recommend the in-house disc approximation test and the commercial D69C, as well as the combination disc test, as excellent tools for detection of AmpC.
The cefoxitin test overcalls AmpC and cannot be considered a good stand-alone test for AmpC detection.

Related Results

Detection of plasmid-mediated AmpC-?-lactamases among clinical isolates:Adiagnostic and therapeutic challenge
Detection of plasmid-mediated AmpC-?-lactamases among clinical isolates:Adiagnostic and therapeutic challenge
Introduction and Aim: The AmpC enzymes are cephalosporinases that impart resistance to a wide range of ?-lactam, ?-lactam/?-lactamase inhibitor combinations, and monobactams, but a...
Rôle du di-AMP cyclique dans la physiologie de Streptococcus agalactiae
Rôle du di-AMP cyclique dans la physiologie de Streptococcus agalactiae
Streptococcus agalactiae, également appelé streptocoque du groupe B (SGB) est une bactérie à Gram positif, capsulée, commensale des voies digestives et urogénitales. Cependant, le ...
Structure-function studies of β-lactamases
Structure-function studies of β-lactamases
Etudes structure-fonction des β-lactamases pour la conception rationnelle de pan-inhibiteurs La résistance antimicrobienne est devenue un problème majeur de santé p...
Voie de l'AMPc et cytosquelette au cours de polarisation et la migration des lymphocytes T en réponse aux chimiokines
Voie de l'AMPc et cytosquelette au cours de polarisation et la migration des lymphocytes T en réponse aux chimiokines
Lors de la stimulation par les chimiokines, les lymphocytes T se polarisent (acquisition d'un lamellipode et d'un uropode) puis entament leur migration. Ce processus est particuliè...
Molecular Detection of Ampicillinase blaEBCM, blaFOX and blaDHAM resistant genes in multi-drug resistant Gram-negative bacteria
Molecular Detection of Ampicillinase blaEBCM, blaFOX and blaDHAM resistant genes in multi-drug resistant Gram-negative bacteria
Background: Multidrug-resistant (MDR) Gram-negative bacteria (GNB) harboring AmpC β-lactamase determinants represent a significant global public health threat, contributing to life...
Current trends in multidrug-resistant AmpC beta-lactamase producing Enterobacter cloacae isolated from a tertiary care hospital
Current trends in multidrug-resistant AmpC beta-lactamase producing Enterobacter cloacae isolated from a tertiary care hospital
Background: The emergence of AmpC beta-lactamase producing Enterobacter cloacae becomes a serious nosocomial menace due to wider resistance. The study aimed to know the existence o...
GENE SINH CARBAPENEMASE KẾT HỢP GENE SINH ESBL, AMPC TRONG ĐỀ KHÁNG KHÁNG SINH CỦA KLEBSIELLA PNEUMONIAE
GENE SINH CARBAPENEMASE KẾT HỢP GENE SINH ESBL, AMPC TRONG ĐỀ KHÁNG KHÁNG SINH CỦA KLEBSIELLA PNEUMONIAE
Đặt vấn đề: Klebsiella pneumoniae hiện nay được xác định là vi khuẩn đa kháng có tỷ lệ kháng kháng sinh cao, kể cả kháng sinh thế hệ mới do có sự kết hợp gene sinh carbapenenase vớ...

Back to Top