Javascript must be enabled to continue!
Accuracy of cup alignment in total hip arthroplasty – a comparison between the portable navigation and goniometer
View through CrossRef
Abstract
Navigation systems, including portable navigation systems, used for total hip arthroplasty (THA) are useful for achieving higher cup alignment accuracy. NAVBIT, a newly available portable navigation system, uses a unique registration method, the table tilt registration. However, its accuracy is unclear. This retrospective study aimed to investigate whether THA with a portable navigation system in the lateral position with the flip technique is more accurate than THA with a cup goniometer in the supine or lateral positions. This study included 96 consecutive patients (77 women, 19 men). The accuracy of cup orientation was compared among the three groups. The absolute values of the difference in cup inclination and anteversion with the NAVBIT (2.1 ± 1.7°, 2.0 ± 1.4°) were smaller than that with the cup goniometer in the supine (3.4 ± 2.4°, 3.4 ± 2.2°) and lateral decubitus positions (3.4 ± 2.5°, 5.0 ± 3.5°). Ninety-one percent, 64.5%, and 56.3% were within 5° of the target angle in the navigation, supine goniometer, and lateral goniometer groups, respectively. The accuracy of cup alignment with the portable navigation system using the flip technique was significantly higher than that with the cup goniometer in the supine and lateral decubitus positions.
Research Square Platform LLC
Title: Accuracy of cup alignment in total hip arthroplasty – a comparison between the portable navigation and goniometer
Description:
Abstract
Navigation systems, including portable navigation systems, used for total hip arthroplasty (THA) are useful for achieving higher cup alignment accuracy.
NAVBIT, a newly available portable navigation system, uses a unique registration method, the table tilt registration.
However, its accuracy is unclear.
This retrospective study aimed to investigate whether THA with a portable navigation system in the lateral position with the flip technique is more accurate than THA with a cup goniometer in the supine or lateral positions.
This study included 96 consecutive patients (77 women, 19 men).
The accuracy of cup orientation was compared among the three groups.
The absolute values of the difference in cup inclination and anteversion with the NAVBIT (2.
1 ± 1.
7°, 2.
0 ± 1.
4°) were smaller than that with the cup goniometer in the supine (3.
4 ± 2.
4°, 3.
4 ± 2.
2°) and lateral decubitus positions (3.
4 ± 2.
5°, 5.
0 ± 3.
5°).
Ninety-one percent, 64.
5%, and 56.
3% were within 5° of the target angle in the navigation, supine goniometer, and lateral goniometer groups, respectively.
The accuracy of cup alignment with the portable navigation system using the flip technique was significantly higher than that with the cup goniometer in the supine and lateral decubitus positions.
Related Results
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Running is a popular form of exercise that is accompanied by many health benefits. However, running also comes with a risk of overuse injuries. Women have a higher risk for overuse...
Accuracy of cup alignment in total hip arthroplasty – a comparison between the portable navigation and alignment guide
Accuracy of cup alignment in total hip arthroplasty – a comparison between the portable navigation and alignment guide
Abstract
Background
Navigation systems, including portable navigation systems, used for total hip arthroplasty (THA) are useful for achieving higher cup alignment accuracy...
Comparison of functional outcome between Bipolar Hemiarthroplasty and total Hip Arthroplasty for displaced femoral neck fractures in elderly patients
Comparison of functional outcome between Bipolar Hemiarthroplasty and total Hip Arthroplasty for displaced femoral neck fractures in elderly patients
Objectives: The intention of this study to compare functional outcomes between Total Hip Arthroplasty and Bipolar Hemi Arthroplasty for displaced femoral neck fracture after 3 mont...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
AbstractBackgroundRelationships between low back pain (LBP) and the hip in patient cohorts have been described primarily in patients with moderate to severe hip osteoarthritis (OA)...
Vitamin D and periprosthetic infection: Review of literature (Preprint)
Vitamin D and periprosthetic infection: Review of literature (Preprint)
BACKGROUND
Infections are rare events in arthroplasty surgeries, occurring in only 0.5% to 2% of procedures. It significantly impacts all involved parts (pa...
No Difference in Hip Muscle Volumes and Fatty Infiltration in Those With Hip-Related Pain Compared to Controls
No Difference in Hip Muscle Volumes and Fatty Infiltration in Those With Hip-Related Pain Compared to Controls
Background
Little is known about muscle morphology in people with hip-related pain, without signs of femoro-acetabular impingement syndrome (FAIS). Identifying ...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract
Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fr...

