Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Fault Detection and Protection Strategy for Multi-Terminal HVDC Grids Using Wavelet Analysis

View through CrossRef
The growing demand for electricity, integration of renewable energy sources, and recent advances in power electronics have driven the development of HVDC systems. Multi-terminal HVDC (MTDC) grids, enabled by Voltage Source Converters (VSCs), provide increased operational flexibility, including the ability to reverse power flow and independently control both active and reactive power. However, fault propagation in DC grids occurs more rapidly, potentially leading to significant damage within milliseconds. Unlike AC systems, HVDC systems lack natural zero-crossing points, making fault isolation more complex. This paper presents the implementation of a wavelet-based protection algorithm to detect faults in a four-terminal VSC-HVDC grid, modelled in MATLAB and SIMULINK. The study considers several fault scenarios, including two internal DC pole-to-ground faults, an external DC fault in the load branch, and an external AC fault outside the protected area. The discrete wavelet transform, using Symlet decomposition, is applied to classify faults based on the wavelet entropy and sharp voltage and current signal variations. The algorithm processes the decomposition coefficients to differentiate between internal and external faults, triggering appropriate relay actions. Key factors influencing the algorithm’s performance include system complexity, fault location, and threshold settings. The suggested algorithm’s reliability and suitability are demonstrated by the real-time implementation. The results confirmed the precise fault detection, with fault currents aligning with the values in offline models. The internal faults exhibit more entropy than external faults. Results demonstrate the algorithm’s effectiveness in detecting faults rapidly and accurately. These outcomes confirm the algorithm’s suitability for a real-time environment.
Title: Fault Detection and Protection Strategy for Multi-Terminal HVDC Grids Using Wavelet Analysis
Description:
The growing demand for electricity, integration of renewable energy sources, and recent advances in power electronics have driven the development of HVDC systems.
Multi-terminal HVDC (MTDC) grids, enabled by Voltage Source Converters (VSCs), provide increased operational flexibility, including the ability to reverse power flow and independently control both active and reactive power.
However, fault propagation in DC grids occurs more rapidly, potentially leading to significant damage within milliseconds.
Unlike AC systems, HVDC systems lack natural zero-crossing points, making fault isolation more complex.
This paper presents the implementation of a wavelet-based protection algorithm to detect faults in a four-terminal VSC-HVDC grid, modelled in MATLAB and SIMULINK.
The study considers several fault scenarios, including two internal DC pole-to-ground faults, an external DC fault in the load branch, and an external AC fault outside the protected area.
The discrete wavelet transform, using Symlet decomposition, is applied to classify faults based on the wavelet entropy and sharp voltage and current signal variations.
The algorithm processes the decomposition coefficients to differentiate between internal and external faults, triggering appropriate relay actions.
Key factors influencing the algorithm’s performance include system complexity, fault location, and threshold settings.
The suggested algorithm’s reliability and suitability are demonstrated by the real-time implementation.
The results confirmed the precise fault detection, with fault currents aligning with the values in offline models.
The internal faults exhibit more entropy than external faults.
Results demonstrate the algorithm’s effectiveness in detecting faults rapidly and accurately.
These outcomes confirm the algorithm’s suitability for a real-time environment.

Related Results

Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems. Concerning fault detection, interv...
HVdc Circuit Breakers: Prospects and Challenges
HVdc Circuit Breakers: Prospects and Challenges
The integration of offshore wind farms has revitalized the interest in multi–terminal high voltage direct current (M–HVdc) transmission grids. HVdc breakers’ importance has increas...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Kajian Kondisi Fisik Terminal Leuwipanjang Berdasarkan Persepsi Penumpang
Kajian Kondisi Fisik Terminal Leuwipanjang Berdasarkan Persepsi Penumpang
Leuwipanjang terminal is a passenger terminal serving AKDP and AKAP. UPTD Terminal is required to provide convenient facilities for passengers during activities within the Terminal...
Coordinated Control of HVDC and HVAC Power Transmission Systems Integrating a Large Offshore Wind Farm
Coordinated Control of HVDC and HVAC Power Transmission Systems Integrating a Large Offshore Wind Farm
The development of efficient and reliable offshore electrical transmission infrastructure is a key factor in the proliferation of offshore wind farms (OWFs). Traditionally, high-vo...
HVDC Interference to Buried Pipeline: Numerical Modeling and Continuous P/S Potential Monitoring
HVDC Interference to Buried Pipeline: Numerical Modeling and Continuous P/S Potential Monitoring
Abstract As one of the most important ways for long-distance transmission of electricity, High Voltage Direct Current (HVDC) transmission lines in China are developi...
Harmonic suppressing control strategy for MMC–HVDC
Harmonic suppressing control strategy for MMC–HVDC
Modular multi‐level converter based high‐voltage direct current transmission (MMC–HVDC), which combines the high‐power capacity of conventional HVDC and the excellent dynamic perfo...
Multiterminal HVDC transmissions systems for offshore wind
Multiterminal HVDC transmissions systems for offshore wind
Offshore wind is emerging as one of the future energy vectors. Offshore wind power plants locations provide more strong and constant wind speed that allows to extract more power co...

Back to Top