Javascript must be enabled to continue!
Oxidized phospholipids reduce ventilator-induced vascular leak and inflammation in vivo
View through CrossRef
Abstract
Background
Mechanical ventilation at high tidal volume (HTV) may cause pulmonary capillary leakage and acute lung inflammation resulting in ventilator-induced lung injury. Besides blunting the Toll-like receptor-4-induced inflammatory cascade and lung dysfunction in a model of lipopolysaccharide-induced lung injury, oxidized 1-palmitoyl-2-arachidonoyl-sn-glycero-3-phosphorylcholine (OxPAPC) exerts direct barrier-protective effects on pulmonary endothelial cells in vitro via activation of the small GTPases Rac and Cdc42. To test the hypothesis that OxPAPC may attenuate lung inflammation and barrier disruption caused by pathologic lung distension, we used a rodent model of ventilator-induced lung injury and an in vitro model of pulmonary endothelial cells exposed to pathologic mechanochemical stimulation.
Methods
Rats received a single intravenous injection of OxPAPC (1.5 mg/kg) followed by mechanical ventilation at low tidal volume (LTV) (7 mL/kg) or HTV (20 mL/kg). Bronchoalveolar lavage was performed and lung tissue was stained for histological analysis. In vitro, the effects of OxPAPC on endothelial barrier dysfunction and GTPase activation were assessed in cells exposed to thrombin and pathologic (18%) cyclic stretch.
Results
HTV induced profound increases in bronchoalveolar lavage and tissue neutrophils and in lavage protein. Intravenous OxPAPC markedly attenuated HTV-induced protein and inflammatory cell accumulation in bronchoalveolar lavage fluid and lung tissue. In vitro, high-magnitude stretch enhanced thrombin-induced endothelial paracellular gap formation associated with Rho activation. These effects were dramatically attenuated by OxPAPC and were associated with OxPAPC-induced activation of Rac.
Conclusion
OxPAPC exhibits protective effects in these models of ventilator-induced lung injury.
Springer Science and Business Media LLC
Title: Oxidized phospholipids reduce ventilator-induced vascular leak and inflammation in vivo
Description:
Abstract
Background
Mechanical ventilation at high tidal volume (HTV) may cause pulmonary capillary leakage and acute lung inflammation resulting in ventilator-induced lung injury.
Besides blunting the Toll-like receptor-4-induced inflammatory cascade and lung dysfunction in a model of lipopolysaccharide-induced lung injury, oxidized 1-palmitoyl-2-arachidonoyl-sn-glycero-3-phosphorylcholine (OxPAPC) exerts direct barrier-protective effects on pulmonary endothelial cells in vitro via activation of the small GTPases Rac and Cdc42.
To test the hypothesis that OxPAPC may attenuate lung inflammation and barrier disruption caused by pathologic lung distension, we used a rodent model of ventilator-induced lung injury and an in vitro model of pulmonary endothelial cells exposed to pathologic mechanochemical stimulation.
Methods
Rats received a single intravenous injection of OxPAPC (1.
5 mg/kg) followed by mechanical ventilation at low tidal volume (LTV) (7 mL/kg) or HTV (20 mL/kg).
Bronchoalveolar lavage was performed and lung tissue was stained for histological analysis.
In vitro, the effects of OxPAPC on endothelial barrier dysfunction and GTPase activation were assessed in cells exposed to thrombin and pathologic (18%) cyclic stretch.
Results
HTV induced profound increases in bronchoalveolar lavage and tissue neutrophils and in lavage protein.
Intravenous OxPAPC markedly attenuated HTV-induced protein and inflammatory cell accumulation in bronchoalveolar lavage fluid and lung tissue.
In vitro, high-magnitude stretch enhanced thrombin-induced endothelial paracellular gap formation associated with Rho activation.
These effects were dramatically attenuated by OxPAPC and were associated with OxPAPC-induced activation of Rac.
Conclusion
OxPAPC exhibits protective effects in these models of ventilator-induced lung injury.
Related Results
Non-Gastrointestinal Complications and Short-Term Outcomes in Patients With Anastomotic Leak After Colon Resection: A Propensity Matched Analysis of American College of Surgeons National Surgical Quality Improvement Program Database
Non-Gastrointestinal Complications and Short-Term Outcomes in Patients With Anastomotic Leak After Colon Resection: A Propensity Matched Analysis of American College of Surgeons National Surgical Quality Improvement Program Database
Introduction: Anastomotic leak is a devastating complication after colorectal surgery. There is paucity of data on non-gastrointestinal complications after anastomotic leak in this...
Adaptive split ventilator system enables parallel ventilation, individual monitoring and ventilation pressures control for each lung simulators
Adaptive split ventilator system enables parallel ventilation, individual monitoring and ventilation pressures control for each lung simulators
Abstract
Objective
In mass crisis setting such as the COVID-19 pandemic, the number of patients requiring ...
Multiscale characterization of microstructural reconfiguration induced by oxidation in lignite from the Lingquan mining colliery
Multiscale characterization of microstructural reconfiguration induced by oxidation in lignite from the Lingquan mining colliery
Abstract
The microstructure changes of Lingquan mine oxidized lignite at different oxidation temperatures and the influence of low-temperature oxidation on the spontaneou...
Performance of the Oxylog® 1000 portable ventilator in a hyperbaric environment
Performance of the Oxylog® 1000 portable ventilator in a hyperbaric environment
Introduction: The management of mechanically ventilated patients in the hyperbaric environment requires knowledge of how the physical properties of gases change under pressure and ...
Critical care nurses' knowledge and attitudes toward using ventilator waveform monitoring to detect patient-ventilator asynchrony: A cross-sectional online survey
Critical care nurses' knowledge and attitudes toward using ventilator waveform monitoring to detect patient-ventilator asynchrony: A cross-sectional online survey
Abstract
Background
Most mechanically ventilated patients will be exposed to some asynchrony with the ventilator. Inability to detect and manage patient-ventilator asynchr...
Efficacy of compliance with ventilator-associated pneumonia care bundle: A 24-month longitudinal study at Bach Mai Hospital, Vietnam
Efficacy of compliance with ventilator-associated pneumonia care bundle: A 24-month longitudinal study at Bach Mai Hospital, Vietnam
Introduction:
To decrease the risk of complications from ventilator-associated pneumonia, it is essential to implement preventative measures in all ICU patients...
Automatic pipeline leak detection based on AST deep learning using a free-swimming detector with acoustic resonance cavity
Automatic pipeline leak detection based on AST deep learning using a free-swimming detector with acoustic resonance cavity
Abstract
The free-swimming in-pipe spherical detector (SD) has found practical application in pipeline leak detection due to its proximity to the leak points, low ri...
Rigless Well Intervention Using Tubing Patch Technology Helps Restore Inactive Wells
Rigless Well Intervention Using Tubing Patch Technology Helps Restore Inactive Wells
Abstract
This paper provides in-depth analysis of a low-cost solution to economically sustain production and avoid high workover costs. This paper conducts the techn...

