Javascript must be enabled to continue!
Reconstruction of the Physiological Behavior of Real and Synthetic Vessels in Controlled Conditions
View through CrossRef
The objective of this study is to assess the ability of an Artificial Circulatory Phantom (ACP) to verify its accuracy in simulating the movement of artificial vessels vs. real vessels under changing cardiovascular parameters such as heartbeat, ejection fraction, and total peripheral resistance. The experiments were conducted with blood-like fluid that flows through two types of vessels: iliac arteries and different types of ePTFE vascular prostheses. Parameters such as diameter and tortuosity were measured and analyzed. The flow characteristics included a pulsating pattern with a frequency of 60–120 min−1 and ejection volumes ranging from 70 to 115 mL. The results showed a predominantly positive correlation between wall displacement (Wd) and tortuosity index (Ti) for the iliac artery (R2 = 0.981), as well as between Wd and mean tortuosity index (MTi) (R2 = 0.994). Similarly, positive correlations between Wd and Ti (R2 = 0.942) and Wd and MTi (R2 = 0.922) were computed for the ePTFE vascular prosthesis. The ACP introduced in this study is a valuable tool for evaluating various vessel types and the spatial configurations of vascular prostheses under diverse hemodynamic conditions. These findings are promising for the advancement of novel approaches to the testing and design of vascular grafts, ultimately enhancing their patency rates in future applications.
Title: Reconstruction of the Physiological Behavior of Real and Synthetic Vessels in Controlled Conditions
Description:
The objective of this study is to assess the ability of an Artificial Circulatory Phantom (ACP) to verify its accuracy in simulating the movement of artificial vessels vs.
real vessels under changing cardiovascular parameters such as heartbeat, ejection fraction, and total peripheral resistance.
The experiments were conducted with blood-like fluid that flows through two types of vessels: iliac arteries and different types of ePTFE vascular prostheses.
Parameters such as diameter and tortuosity were measured and analyzed.
The flow characteristics included a pulsating pattern with a frequency of 60–120 min−1 and ejection volumes ranging from 70 to 115 mL.
The results showed a predominantly positive correlation between wall displacement (Wd) and tortuosity index (Ti) for the iliac artery (R2 = 0.
981), as well as between Wd and mean tortuosity index (MTi) (R2 = 0.
994).
Similarly, positive correlations between Wd and Ti (R2 = 0.
942) and Wd and MTi (R2 = 0.
922) were computed for the ePTFE vascular prosthesis.
The ACP introduced in this study is a valuable tool for evaluating various vessel types and the spatial configurations of vascular prostheses under diverse hemodynamic conditions.
These findings are promising for the advancement of novel approaches to the testing and design of vascular grafts, ultimately enhancing their patency rates in future applications.
Related Results
Woningcorporaties en Vastgoedontwikkeling
Woningcorporaties en Vastgoedontwikkeling
This summary highlights the findings of the PhD-thesis ‘Woningcorporaties en Vastgoedontwikkeling: Fit for Use’ (‘Housing associations and Real Estate Development: Fit for Use?’). ...
Vessels from Late Medieval cemeteries in the Central Balkans
Vessels from Late Medieval cemeteries in the Central Balkans
Although a rare occurrence in late medieval cemeteries, vessels have been
found on almost all major sites of the period, such as Novo Brdo, Trgoviste,
Reljina Gradina and the...
Marine Operations For Platform Maintenance And Repair
Marine Operations For Platform Maintenance And Repair
Abstract
This paper is concerned with the history of the development of submarine and diving support vessels in the North Sea and an analysis of future trends bas...
Tidlig neolitiske anlæg ved Tolstrup
Tidlig neolitiske anlæg ved Tolstrup
Early Neolithic structures at Tolstrup near Løgstør In 1965, excavation revealed Early Neolithic structures of the Funnel Beaker culture at the village of Tolstrup, not far east o...
Abstract P6-09-10: Informational needs among women considering breast reconstruction post-mastectomy.
Abstract P6-09-10: Informational needs among women considering breast reconstruction post-mastectomy.
Abstract
For many women, the complexity of processing and learning about their breast cancer diagnosis is further complicated by decisions to be made about breast re...
Real-Time Dynamic Full Scene Reconstruction Using a Heterogeneous Sensor System
Real-Time Dynamic Full Scene Reconstruction Using a Heterogeneous Sensor System
<p dir="ltr"><b>This thesis presents a novel method for reconstructing full dynamic environments in real-time using either live or recorded data. The ability to recreat...
Patient informational needs about breast reconstruction post-mastectomy.
Patient informational needs about breast reconstruction post-mastectomy.
88 Background: For many women, receiving a breast cancer diagnosis is further complicated by decisions they will face about breast reconstruction post-mastectomy. While women are ...
Natural History and Treatment Modalities of Symptomatic Bilateral Middle Cerebral Artery Stenosis
Natural History and Treatment Modalities of Symptomatic Bilateral Middle Cerebral Artery Stenosis
To assess the natural history, pathogenesis, and treatment modalities of symptomatic bilateral middle cerebral artery stenosis, we retrospectively evaluated a consecutive series of...

