Javascript must be enabled to continue!
Worsening of gas exchange parameters at high FiO2 in COVID-19: misleading or informative?
View through CrossRef
Background: In COVID-19, higher than expected level of intrapulmonary shunt has been described, in association with a discrepancy between the initial relatively preserved lung mechanics and the hypoxia severity. This study aim was to measure the shunt fraction and variations of PaO2/FiO2 ratio and oxygen alveolar-arterial gradient (A-a O2) at different FiO2.Methods: Shunt was measured by a non-invasive system during spontaneous breathing in 12 patients hospitalized at COVID-19 Semi-Intensive Care Unit of Papa Giovanni XXIII Hospital, Bergamo, Italy, between October 22 and November 23, 2020.Results: Nine patients were men, mean age (±SD) 62±15 years, mean BMI 27.5±4.8 Kg/m2. Systemic hypertension, diabetes type 2 and previous myocardial infraction were referred in 33%, 17%, and 7%, respectively. Mean PaO2/FiO2 ratio was 234±66 and 11 patients presented a bilateral chest X-ray involvement. Mean shunt was 21±6%. Mainly in patients with a more severe respiratory failure, we found a progressive decrease of PaO2/FiO2 ratio with higher FiO2. Considering (A-a O2), we found a uniform tendency to increase with FiO2 increasing. Even in this case, the more severe were the patients, the higher was the slope, suggesting FiO2 insensitiveness due to a shunt effect, as strengthened by our measurements.Conclusion: Relying on a single evaluation of PaO2/FiO2 ratio, especially at high FiO2, could be misleading in COVID-19. We propose a two steps evaluation, the first at low SpO2 value (e.g., 92-94%) and the second one at high FiO2 (i.e., >0.7), allowing to characterize both the amendable (ventilation/perfusion mismatch), and the fixed (shunt) contribution quote of respiratory impairment, respectively.
Title: Worsening of gas exchange parameters at high FiO2 in COVID-19: misleading or informative?
Description:
Background: In COVID-19, higher than expected level of intrapulmonary shunt has been described, in association with a discrepancy between the initial relatively preserved lung mechanics and the hypoxia severity.
This study aim was to measure the shunt fraction and variations of PaO2/FiO2 ratio and oxygen alveolar-arterial gradient (A-a O2) at different FiO2.
Methods: Shunt was measured by a non-invasive system during spontaneous breathing in 12 patients hospitalized at COVID-19 Semi-Intensive Care Unit of Papa Giovanni XXIII Hospital, Bergamo, Italy, between October 22 and November 23, 2020.
Results: Nine patients were men, mean age (±SD) 62±15 years, mean BMI 27.
5±4.
8 Kg/m2.
Systemic hypertension, diabetes type 2 and previous myocardial infraction were referred in 33%, 17%, and 7%, respectively.
Mean PaO2/FiO2 ratio was 234±66 and 11 patients presented a bilateral chest X-ray involvement.
Mean shunt was 21±6%.
Mainly in patients with a more severe respiratory failure, we found a progressive decrease of PaO2/FiO2 ratio with higher FiO2.
Considering (A-a O2), we found a uniform tendency to increase with FiO2 increasing.
Even in this case, the more severe were the patients, the higher was the slope, suggesting FiO2 insensitiveness due to a shunt effect, as strengthened by our measurements.
Conclusion: Relying on a single evaluation of PaO2/FiO2 ratio, especially at high FiO2, could be misleading in COVID-19.
We propose a two steps evaluation, the first at low SpO2 value (e.
g.
, 92-94%) and the second one at high FiO2 (i.
e.
, >0.
7), allowing to characterize both the amendable (ventilation/perfusion mismatch), and the fixed (shunt) contribution quote of respiratory impairment, respectively.
Related Results
Limitations of SpO2 / FiO2-ratio for classification and monitoring of acute respiratory distress syndrome—an observational cohort study
Limitations of SpO2 / FiO2-ratio for classification and monitoring of acute respiratory distress syndrome—an observational cohort study
Abstract
Background
The ratio of pulse-oximetric peripheral oxygen saturation to fraction of inspired oxygen (SpO2/FiO2) has been proposed as add...
Burden of the Beast
Burden of the Beast
Introduction
Throughout the COVID-19 pandemic, and its fluctuating waves of infections and the emergence of new variants, Indigenous populations in Australia and worldwide have re...
The Impact of Different Inspired Oxygen Concentrations Combined with Nebulized Prostaglandin E1 on Oxygenation in Patients Undergoing One- Lung Ventilation
The Impact of Different Inspired Oxygen Concentrations Combined with Nebulized Prostaglandin E1 on Oxygenation in Patients Undergoing One- Lung Ventilation
Abstract
Background: One-lung ventilation (OLV) requires a high inspired oxygen concentration (FiO2) to promote oxygenation improvement, yet it increases the risk of postop...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract
The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
A new reservoir-based CPAP with low oxygen consumption. The Bag-CPAP
A new reservoir-based CPAP with low oxygen consumption. The Bag-CPAP
Abstract
Background
Several forms of noninvasive ventilatory supports have a high consumption of oxygen which may precipitate oxygen shortage, as experienced during the COV...
Oxygen management in New Zealand and Australian intensive care units: A knowledge translation study
Oxygen management in New Zealand and Australian intensive care units: A knowledge translation study
<p><b>Background: Knowledge translation literature shows a delay between publication and uptake of research findings into clinical practice. There is uncertainty about ...
Oxygen management in New Zealand and Australian intensive care units: A knowledge translation study
Oxygen management in New Zealand and Australian intensive care units: A knowledge translation study
<p><b>Background: Knowledge translation literature shows a delay between publication and uptake of research findings into clinical practice. There is uncertainty about...

