Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Reliability and Validity of T‐scan and 3D Intraoral Scanning for Measuring the Occlusal Contact Area

View through CrossRef
AbstractPurposeTo determine the reliability of T‐scan and 3D intraoral scan techniques for assessing the occlusal contact area (OCA), compared to occlusal registration and also to assess the validity of the techniques.Materials and MethodsThirty‐one dentate adults participated in this cross‐sectional study. T‐scan records were used to measure the OCA at maximum bite force and at 50% of maximum force using the software's bite force selection tool. A second method measured the OCA between 2 virtual models scanned intraorally using a 3D surface scan and considering the occlusal contact at 2 interocclusal distances (0‐100 and 0‐200 µm). The third method measured OCA using occlusal registration at moderate and maximum occlusal force, and considering contact at the 2 interocclusal distances (0‐100 and 0‐200 µm). Images obtained using the 3 methods were analyzed using ImageJ software. Test‐retest reliability was assessed by the intraclass correlation coefficient (ICC) and validity by Pearson correlations.ResultsICCs ranged from 0.56 to 0.79 (p < 0.001) for the T‐scan; 0.37 to 0.61 (p < 0.05) for 3D surface scan; and 0.92 to 0.95 (p < 0.0005) for occlusal registration. The highest OCA values were obtained using the T‐scan, and the lowest using the 3D surface scan. Occlusal registration measurements had the highest correlations with those of the other techniques.ConclusionsT‐scan is a reliable method for measuring the OCA, but the 3D surface scan is not. Occlusal registration showed a high validity.
Title: Reliability and Validity of T‐scan and 3D Intraoral Scanning for Measuring the Occlusal Contact Area
Description:
AbstractPurposeTo determine the reliability of T‐scan and 3D intraoral scan techniques for assessing the occlusal contact area (OCA), compared to occlusal registration and also to assess the validity of the techniques.
Materials and MethodsThirty‐one dentate adults participated in this cross‐sectional study.
T‐scan records were used to measure the OCA at maximum bite force and at 50% of maximum force using the software's bite force selection tool.
A second method measured the OCA between 2 virtual models scanned intraorally using a 3D surface scan and considering the occlusal contact at 2 interocclusal distances (0‐100 and 0‐200 µm).
The third method measured OCA using occlusal registration at moderate and maximum occlusal force, and considering contact at the 2 interocclusal distances (0‐100 and 0‐200 µm).
Images obtained using the 3 methods were analyzed using ImageJ software.
Test‐retest reliability was assessed by the intraclass correlation coefficient (ICC) and validity by Pearson correlations.
ResultsICCs ranged from 0.
56 to 0.
79 (p < 0.
001) for the T‐scan; 0.
37 to 0.
61 (p < 0.
05) for 3D surface scan; and 0.
92 to 0.
95 (p < 0.
0005) for occlusal registration.
The highest OCA values were obtained using the T‐scan, and the lowest using the 3D surface scan.
Occlusal registration measurements had the highest correlations with those of the other techniques.
ConclusionsT‐scan is a reliable method for measuring the OCA, but the 3D surface scan is not.
Occlusal registration showed a high validity.

Related Results

Domination of Polynomial with Application
Domination of Polynomial with Application
In this paper, .We .initiate the study of domination. polynomial , consider G=(V,E) be a simple, finite, and directed graph without. isolated. vertex .We present a study of the Ira...
CLINICAL ASPECTS OF RECORDING OCCLUSAL CONTACTS USING CONVENTIONAL METHODS AND INTRA-ORAL SCANNING
CLINICAL ASPECTS OF RECORDING OCCLUSAL CONTACTS USING CONVENTIONAL METHODS AND INTRA-ORAL SCANNING
Aim of the study. The aim of the current study was to analyze and compare the registration of the occlusal contact points using three intraoral scanners and articulation paper. Mat...
Comparative Study of Different Materials for Occlusal Matrix Technique in Posterior Teeth
Comparative Study of Different Materials for Occlusal Matrix Technique in Posterior Teeth
Posterior composite restorations are difficult to contour and polish due to their occlusal anatomy and opposing occlusion. Our study describes a technique for duplicating occlusal ...
Digital Occlusion Analysis after Orthodontic Treatment: Capabilities of the Intraoral Scanner and T-Scan Novus System
Digital Occlusion Analysis after Orthodontic Treatment: Capabilities of the Intraoral Scanner and T-Scan Novus System
Digital technology is becoming increasingly popular in dentistry. The aim of this article is to demonstrate and compare the capabilities of two different digital approaches, namely...

Back to Top