Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Doppler ultrasound twinkling artifact on crevices etched in silicon wafers

View through CrossRef
The twinkling artifact, or rapid color shifts, are observed when imaging kidney stones and other mineralizations. The current theory is that scattering from bubbles in micron-sized crevices causes twinkling. Our objective is to investigate the effect of ultrasound frequency and crevice size and number on twinkling of silicon wafers. Ten or 100 randomly positioned cylindrical crevices with diameters of 1, 10, or 100 μm and depths of 10 μm were dry-etched on wafers. A research ultrasound system was used to image wafers at 5, 7.8, and 18.5 MHz; IQ data were post-processed to calculate twinkling or Doppler power. Twinkling for all crevice sizes and numbers followed the trend 5 MHz>7.8 MHz>18.5 MHz. For crevice size, at 5 and 7.8 MHz, twinkling was higher for 1- or 10-μm crevices compared to 100 μm; at 18.5 MHz, twinkling was only observed on 100-μm crevices. Increasing the number of crevices increased twinkling for 1 μm crevices at 5 and 7.8 MHz and 10 μm crevices at 7.8 MHz; no differences were noted at 18.5 MHz. These results support previous work showing twinkling is frequency-dependent and suggest that even 10, 1-μm crevices are sufficient to cause twinkling. [Work supported by SURIEA, NSF CAREER-1943937.]
Title: The Doppler ultrasound twinkling artifact on crevices etched in silicon wafers
Description:
The twinkling artifact, or rapid color shifts, are observed when imaging kidney stones and other mineralizations.
The current theory is that scattering from bubbles in micron-sized crevices causes twinkling.
Our objective is to investigate the effect of ultrasound frequency and crevice size and number on twinkling of silicon wafers.
Ten or 100 randomly positioned cylindrical crevices with diameters of 1, 10, or 100 μm and depths of 10 μm were dry-etched on wafers.
A research ultrasound system was used to image wafers at 5, 7.
8, and 18.
5 MHz; IQ data were post-processed to calculate twinkling or Doppler power.
Twinkling for all crevice sizes and numbers followed the trend 5 MHz>7.
8 MHz>18.
5 MHz.
For crevice size, at 5 and 7.
8 MHz, twinkling was higher for 1- or 10-μm crevices compared to 100 μm; at 18.
5 MHz, twinkling was only observed on 100-μm crevices.
Increasing the number of crevices increased twinkling for 1 μm crevices at 5 and 7.
8 MHz and 10 μm crevices at 7.
8 MHz; no differences were noted at 18.
5 MHz.
These results support previous work showing twinkling is frequency-dependent and suggest that even 10, 1-μm crevices are sufficient to cause twinkling.
[Work supported by SURIEA, NSF CAREER-1943937.
].

Related Results

B-Mode Sonography Versus Color Doppler Twinkling Artifact in the Diagnosis of Nephrolithiasis
B-Mode Sonography Versus Color Doppler Twinkling Artifact in the Diagnosis of Nephrolithiasis
Background: Nephrolithiasis, or kidney stones, is a prevalent condition that prompts numerous patient visits to emergency departments worldwide. The diagnosis of this condition and...
Diagnostic accuracy of doppler twinkling artifact in diagnosing smaller than 5 mm urolithiasis
Diagnostic accuracy of doppler twinkling artifact in diagnosing smaller than 5 mm urolithiasis
Background: The Doppler twinkling effect has also become a promising adjunctive method to improve the ultrasound image of small urinary stones. The aim of the current research was ...
Twinkle, twinkle little stone: an artifact improves the ultrasound performance!
Twinkle, twinkle little stone: an artifact improves the ultrasound performance!
Aims: Ultrasound is a noninvasive method used for the diagnosis of urinary lithiasis. When the length of the stone is less than 5 mm, its detection may be difficult. The twinkling ...
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v1
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v1
Modern plant tissues are often processed for phytolith analysis. They represent a fundamental source of comparison for archeological and palaeoenvironmental phytolith assemblages; ...
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v2
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v2
Modern plant tissues are often processed for phytolith analysis. They represent a fundamental source of comparison for archeological and palaeoenvironmental phytolith assemblages; ...
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v1
Phytolith extraction and counting procedure for modern plant material rich in silica skeletons v1
Modern plant tissues are often processed for phytolith analysis. They represent a fundamental source of comparison for archeological and palaeoenvironmental phytolith assemblages; ...
Diagnostic efficacy of ultrasonography, Doppler ultrasonography and elastography in the evaluation of suspected malignant lymph nodes
Diagnostic efficacy of ultrasonography, Doppler ultrasonography and elastography in the evaluation of suspected malignant lymph nodes
Aim: In this prospective study, the efficiency of imaging findings was investigated by comparing the histopathological results of lymph nodes with Doppler and ultrasound features a...
(Invited) Thin Porous Silicon Produced By Metal-Assisted Etching
(Invited) Thin Porous Silicon Produced By Metal-Assisted Etching
Metal-assisted etching of silicon can produce porous silicon and silicon nanowires by simply immersing metal-modified silicon in a hydrofluoric acid solution without electrical bia...

Back to Top