Javascript must be enabled to continue!
Effect of rotation on achieving constant voltage in three-phase self-excited induction generator for small scale wind turbines application
View through CrossRef
Three-phase Self-Excited Induction Generators (SEIGs) are commonly employed for electricity generation in remote or isolated areas. SEIGs are preferred in such regions due to their ability to create a magnetic field by adding a capacitor to one of their terminals. Nevertheless, a significant challenge in utilizing SEIGs is maintaining a consistent output voltage in the presence of load fluctuations. This study aims to investigate the impact of generator rotation on the SEIG's output voltage and determine the optimal rotation speed required for achieving a stable output voltage. Ensuring stable voltage regulation is crucial to guarantee the proper functioning of all loads connected to the SEIG. Furthermore, operating the SEIG in parallel with other generators is advantageous. The methodology employed in this study involves varying the load supplied by the SEIG at different capacitor values. Unwanted voltage variations occur due to load fluctuations within a generating system or SEIG. Adjustments to the generator's rotation speed are made to uphold a uniform voltage level. The variables considered in this study include the generator's rotation speed, capacitor size, and load fluctuations. Simulation results demonstrate that the SEIG's output voltage is affected by the generator's rotation speed, and maintaining a consistent voltage necessitates appropriate adjustments to capacitor values and generator speed. This research enhances understanding of SEIG characteristics and offers guidance on effective settings for maintaining a stable output voltage at various generator rotation speeds. Future research can focus on practically implementing these findings to enhance the performance of SEIGs in real-world applications
Politeknik Negeri Lhokseumawe
Title: Effect of rotation on achieving constant voltage in three-phase self-excited induction generator for small scale wind turbines application
Description:
Three-phase Self-Excited Induction Generators (SEIGs) are commonly employed for electricity generation in remote or isolated areas.
SEIGs are preferred in such regions due to their ability to create a magnetic field by adding a capacitor to one of their terminals.
Nevertheless, a significant challenge in utilizing SEIGs is maintaining a consistent output voltage in the presence of load fluctuations.
This study aims to investigate the impact of generator rotation on the SEIG's output voltage and determine the optimal rotation speed required for achieving a stable output voltage.
Ensuring stable voltage regulation is crucial to guarantee the proper functioning of all loads connected to the SEIG.
Furthermore, operating the SEIG in parallel with other generators is advantageous.
The methodology employed in this study involves varying the load supplied by the SEIG at different capacitor values.
Unwanted voltage variations occur due to load fluctuations within a generating system or SEIG.
Adjustments to the generator's rotation speed are made to uphold a uniform voltage level.
The variables considered in this study include the generator's rotation speed, capacitor size, and load fluctuations.
Simulation results demonstrate that the SEIG's output voltage is affected by the generator's rotation speed, and maintaining a consistent voltage necessitates appropriate adjustments to capacitor values and generator speed.
This research enhances understanding of SEIG characteristics and offers guidance on effective settings for maintaining a stable output voltage at various generator rotation speeds.
Future research can focus on practically implementing these findings to enhance the performance of SEIGs in real-world applications.
Related Results
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background:
In a wind farm, the wind speed of the downstream wind turbine will be
lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...
Aerodynamics of Clustered Wind Lens Turbines
Aerodynamics of Clustered Wind Lens Turbines
Wind lens turbines, developed by Kyushu University have increased performance due to the duct surrounding the rotor [1]. A Multi rotor system is a promising concept to upscale wind...
Wind lidars within Dutch offshore wind farms
Wind lidars within Dutch offshore wind farms
The growing number of wind farms in the Dutch part of the North Sea [1] offers the necessity, as well as the opportunity, to measure the meteorological conditions at these location...
Design and Performance Analysis of Distributed Equal Angle Spiral Vertical Axis Wind Turbine
Design and Performance Analysis of Distributed Equal Angle Spiral Vertical Axis Wind Turbine
Background:
The wind turbine is divided into a horizontal axis and a vertical axis depending
on the relative positions of the rotating shaft and the ground. The advantage of the ch...
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Recently, offshore wind farms have emerged as the most promising sector in the global renewable energy industry. The main reasons for the rapid development of offshore wind farms i...
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Current Source Converter Based Offshore Wind Farm: Configuration and Control
Recently, offshore wind farms have emerged as the most promising sector in the global renewable energy industry. The main reasons for the rapid development of offshore wind farms i...
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Background:
Data suggests that the presence of measurable residual disease (MRD) at the time of transplant for AML portends a poor prognosis. The timing of MRD asses...
Design of a Rooftop Wind Harnessing System With Smart Wind Deflecting Structure
Design of a Rooftop Wind Harnessing System With Smart Wind Deflecting Structure
This work presents a novel design for a rooftop wind tower system; the system is primarily intended for areas of low natural wind speeds. The relatively low natural wind is increas...

