Analysis of Artifacts and Errors on Intraoral Phosphor Plate Radiographs: A Retrospective Study

View through CrossRef
Introduction. The advantages of phosphor plates (PPs), including their flexibility, thinness, and wireless connectivity, have contributed to their widespread use in dentistry alongside the advancement of digital radiography techniques. Continuous use of PPs and certain errors may lead to artifacts on the images. This retrospective study aimed to determine the frequency and types of intraoral PP artifacts. Methods. This study was conducted on 814 intraoral PP radiographs, including periapical and bitewing images. The errors and artifacts were classified into 4 main categories: technical errors, plate-related artifacts, scanner-induced artifacts, and ambient light artifacts. Results. A total of 656 periapical and 158 bitewing radiographs were examined. The most observed artifacts on the radiographs were plate-related artifacts, followed by technical errors (n=542, n=461, respectively). Within the category of plate-related artifacts, the most common artifacts were cracks or scratches (n=418, 77.1%), while within the category of technical errors, these were cone-cut errors (n=188, 40.7%). Parallel or zigzag radiopaque lines were the most common scanner-induced artifacts (n=313, 98.7%) and fading was the most common ambient light artefact (n=93, 49.2%). On more than half of the PPs, more than one artifact group was observed. Conclusions. Cone-cut, cracks/scratches, parallel zigzag radiopaque lines, and fading were common PP artifacts and errors in this study. The analysis revealed that over half of the PPs exhibited appearance of more than one artifact group. The high frequency of artifacts poses a risk of incorrect and incomplete diagnoses in radiographs, emphasizing the crucial importance of understanding the causes and developing effective prevention strategies for artifacts to enhance the reliability of diagnostic imaging and ensure the accuracy of patient assessments.
Ivano-Frankivsk National Medical University
Title: Analysis of Artifacts and Errors on Intraoral Phosphor Plate Radiographs: A Retrospective Study
Description:
Introduction.
The advantages of phosphor plates (PPs), including their flexibility, thinness, and wireless connectivity, have contributed to their widespread use in dentistry alongside the advancement of digital radiography techniques.
Continuous use of PPs and certain errors may lead to artifacts on the images.
This retrospective study aimed to determine the frequency and types of intraoral PP artifacts.
Methods.
This study was conducted on 814 intraoral PP radiographs, including periapical and bitewing images.
The errors and artifacts were classified into 4 main categories: technical errors, plate-related artifacts, scanner-induced artifacts, and ambient light artifacts.
Results.
A total of 656 periapical and 158 bitewing radiographs were examined.
The most observed artifacts on the radiographs were plate-related artifacts, followed by technical errors (n=542, n=461, respectively).
Within the category of plate-related artifacts, the most common artifacts were cracks or scratches (n=418, 77.
1%), while within the category of technical errors, these were cone-cut errors (n=188, 40.
7%).
Parallel or zigzag radiopaque lines were the most common scanner-induced artifacts (n=313, 98.
7%) and fading was the most common ambient light artefact (n=93, 49.
2%).
On more than half of the PPs, more than one artifact group was observed.
Conclusions.
Cone-cut, cracks/scratches, parallel zigzag radiopaque lines, and fading were common PP artifacts and errors in this study.
The analysis revealed that over half of the PPs exhibited appearance of more than one artifact group.
The high frequency of artifacts poses a risk of incorrect and incomplete diagnoses in radiographs, emphasizing the crucial importance of understanding the causes and developing effective prevention strategies for artifacts to enhance the reliability of diagnostic imaging and ensure the accuracy of patient assessments.

Related Results

NICU Medication Errors: Describing the Cause and Nature of Medication Errors in a NICU in Qatar
NICU Medication Errors: Describing the Cause and Nature of Medication Errors in a NICU in Qatar
IntroductionA medication error can be defined as “any error occurring in the medication use process” and focuses on problems with the delivery of medication to a patient [1]. Medic...
Screening of color phosphor powders on CRT faceplates
Screening of color phosphor powders on CRT faceplates
Abstract— We studied the screening of color phosphor powders on CRT faceplates by photolithography. For photolithography, the phosphor particles should disperse perfectly in the dr...
Design of the Ring Remote Phosphor Structure for Phosphor-Converted White-Light-Emitting Diodes
Design of the Ring Remote Phosphor Structure for Phosphor-Converted White-Light-Emitting Diodes
A phosphor-converted light-emitting diode structure with an increased phosphor extraction efficiency owing to the ring remote phosphor structure achieves a maximum luminous efficac...
ADVANCING FORENSIC ODONTOLOGY: UTILIZING INTRAORAL SCANNERS FOR AGE AND SEX DETERMINATION
ADVANCING FORENSIC ODONTOLOGY: UTILIZING INTRAORAL SCANNERS FOR AGE AND SEX DETERMINATION
ABSTRAKLatar Belakang: Odontologi forensik memainkan peran penting dalam identifikasi manusia, terutama dalam memperkirakan usia dan menentukan jenis kelamin. Metode tradisional se...
The Bronze Artifacts of Tall Jalul, Jordan
The Bronze Artifacts of Tall Jalul, Jordan
Background It is quite common at excavation sites throughout the Near East to uncover the remains of metallic artifacts, though the practice of investigating these objects has flu...
Evaluation of endo-perio lesions according to different specific classifications
Evaluation of endo-perio lesions according to different specific classifications
Abstract Introduction: Endo-perio lesions, beyond the clinical examination, are also assessed by means of radiographs. It is important that the radiographs used for diagnos...
Retrospective Study: Evaluating the Positioning Errors in Digital Panoramic Radiographs
Retrospective Study: Evaluating the Positioning Errors in Digital Panoramic Radiographs
To produce a panoramic cardiograph with a constant image quality common errors must be kept to a minimum.This study is conducted with an objective to analyse the most prevalent pos...
Degeneration in Phosphor-within-Glass Encasers Featuring Disparate Phosphor forms Applied to High-Powered LED
Degeneration in Phosphor-within-Glass Encasers Featuring Disparate Phosphor forms Applied to High-Powered LED
For supplanting traditional illuminating diode units (LED) made of silicone, non-organic chroma transmuters featuring significant thermic consistency as well as translucency, inclu...

Back to Top