Abstract. The development of technology in the current era is very rapid and has an impact on increasing electrical energy which is a major need for large industries and households. One of the electrical energy delivery equipment in the transmission system is a PMT or High Connection Breaker. This PMT is a mechanical equipment equipped with sulfur hexafluoride (SF6) gas arc extinguishing media. The process of extinguishing the arc occurs due to contact due to work from the movement that causes the contact to cause an arc. This decrease in SF6 gas pressure greatly affects reliability when operating, because the arc extinguishing process is not perfect. This is determined by the age of the equipment and the number of operating breakers. The results showed that SF6 gas which is in accordance with the standard normal pressure of 6.4 bar with an ambient temperature of 34°C can minimize the occurrence of equipment damage because it is able to approach arc pressure with SF6 gas velocity of 58 cm/s.kA, with a contact gap of 3,61224. cm, while the PMT cannot be operated at a pressure of 5.2 bar with an ambient temperature of 34°C because the speed of SF6 gas is 82 cm/s.kA with a contact gap of 5.10696. It is concluded that the higher the pressure affects the speed and distance when extinguishing the arc. several factors that affect the decrease in SF6 gas pressure using the FMEA method based on the highest value of the Risk Priority Number (RPN) of 810.
Keywords: fire arc, Breakdown, Voltage breaker, SF6 . gas pressure
Jurnal Teknologika, Sekolah Tinggi Teknologi Wastukancana
Title: Analysis of the pressure drop of sulfur hexafluoride (sf6) gas in a circuit breaker 150 KV Siemens 3AQ1EG
Description:
Abstract.
The development of technology in the current era is very rapid and has an impact on increasing electrical energy which is a major need for large industries and households.
One of the electrical energy delivery equipment in the transmission system is a PMT or High Connection Breaker.
This PMT is a mechanical equipment equipped with sulfur hexafluoride (SF6) gas arc extinguishing media.
The process of extinguishing the arc occurs due to contact due to work from the movement that causes the contact to cause an arc.
This decrease in SF6 gas pressure greatly affects reliability when operating, because the arc extinguishing process is not perfect.
This is determined by the age of the equipment and the number of operating breakers.
The results showed that SF6 gas which is in accordance with the standard normal pressure of 6.
4 bar with an ambient temperature of 34°C can minimize the occurrence of equipment damage because it is able to approach arc pressure with SF6 gas velocity of 58 cm/s.
kA, with a contact gap of 3,61224.
cm, while the PMT cannot be operated at a pressure of 5.
2 bar with an ambient temperature of 34°C because the speed of SF6 gas is 82 cm/s.
kA with a contact gap of 5.
10696.
It is concluded that the higher the pressure affects the speed and distance when extinguishing the arc.
several factors that affect the decrease in SF6 gas pressure using the FMEA method based on the highest value of the Risk Priority Number (RPN) of 810.
Keywords: fire arc, Breakdown, Voltage breaker, SF6 .
gas pressure.
Related Results
Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts
Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts
Nowadays, the electric connection circuits of power plants (based on fossil fuels as well as renewable sources) entail generator circuit-breakers (GCBs) at the generator terminals,...
Outcomes of air versus sulfur hexafluoride tamponade in primary rhegmatogenous retinal detachment in phakic eyes
Outcomes of air versus sulfur hexafluoride tamponade in primary rhegmatogenous retinal detachment in phakic eyes
Purpose
To evaluate the outcomes of using air versus sulfur hexafluoride (SF6) gas tamponade in management of primary rhegmatogenous retinal detachment (RRD).
...
Types of Circuit Breaker and its Application in Substation Protection
Types of Circuit Breaker and its Application in Substation Protection
Power system consists of the generation, transmission, distribution, and substation. All the power system component requires suitable protection devices as the protection system to...
Smooth surface glass etching by deep reactive ion etching with SF6 and Xe gases
Smooth surface glass etching by deep reactive ion etching with SF6 and Xe gases
This article reports on a smooth surface glass etching using deep reactive ion etching with a mixture of sulfur hexafluoride (SF6) and xenon (Xe) gases. A surface roughness of 23 Å...
Study and Analysis of Different Types of Circuit Breaker
Study and Analysis of Different Types of Circuit Breaker
Circuit breakers play an important role in an electrical system performance in terms of system safety, control, maintenance and cost. In some cases, the conventional mechanical cir...
Microporous covalent organic frameworks for sulfur hexafluoride capture and separation
Microporous covalent organic frameworks for sulfur hexafluoride capture and separation
Sulfur hexafluoride (SF6) is the most potent greenhouse gas whose emission is in great need of reducing during the indus-trial processes. Here, a variety of covalent organic framew...
Positive and Negative Ions in RF Plasmas of SF 6/N 2 and SF 6/Ar Mixtures in a Planar Diode
Positive and Negative Ions in RF Plasmas of SF 6/N 2 and SF 6/Ar Mixtures in a Planar Diode
Ionic species in 13.56 MHz discharge of SF6/N2 and SF6/Ar mixtures were measured by means of direct sampling using a quadrupole mass spectrometer. Dominant negative ions in the SF6...
Improvement of Steam Turbine Stage Efficiency by Controlling Rotor Shroud Leakage Flows: Part II — Effect of Axial Distance Between a Swirl Breaker and Rotor Shroud on Efficiency Improvement
Improvement of Steam Turbine Stage Efficiency by Controlling Rotor Shroud Leakage Flows: Part II — Effect of Axial Distance Between a Swirl Breaker and Rotor Shroud on Efficiency Improvement
The basic principle of a distinct idea to reduce an aerodynamic mixing loss induced by the difference in tangential velocity between mainstream flow and rotor shroud leakage flow i...