Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Laparoscopic Transabdominal Preperitoneal Inguinal Hernia Repair Using Memory-Ring Mesh: A Pilot Study

View through CrossRef
Purpose.To evaluate the feasibility, safety, and effectiveness of laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair using a memory-ring patch (Polysoft™mesh).Patients and Methods.Between April 2010 and March 2013, a total of 76 inguinal hernias underwent TAPP repair using Polysoft mesh in 67 adults under general anesthesia. Three different senior resident surgeons performed TAPP repair under the instruction of a specialist surgeon. Nine patients had bilateral hernias. The 76 hernias included 37 indirect inguinal hernias, 29 direct hernias, 1 femoral hernia, 1 pantaloon hernia (combined direct/indirect inguinal hernia), and 8 recurrent hernias after open anterior hernia repair. The immediate postoperative outcomes as well as the short-term outcomes (mainly recurrence and incidence of chronic pain) were studied.Results.There was no conversion from TAPP repair to anterior open repair. The mean operation time was 109 minutes (range, 40–132) for unilateral hernia repair. Scrotal seroma was diagnosed at the operation site in 5 patients. No patient had operation-related orchitis, testicle edema, trocar site infection, or chronic pain during follow-up.Conclusions.The use of Polysoft mesh for TAPP inguinal hernia repair does not seem to adversely affect the quality of repair. The use of this mesh is therefore feasible and safe and may reduce postoperative pain.
Title: Laparoscopic Transabdominal Preperitoneal Inguinal Hernia Repair Using Memory-Ring Mesh: A Pilot Study
Description:
Purpose.
To evaluate the feasibility, safety, and effectiveness of laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair using a memory-ring patch (Polysoft™mesh).
Patients and Methods.
Between April 2010 and March 2013, a total of 76 inguinal hernias underwent TAPP repair using Polysoft mesh in 67 adults under general anesthesia.
Three different senior resident surgeons performed TAPP repair under the instruction of a specialist surgeon.
Nine patients had bilateral hernias.
The 76 hernias included 37 indirect inguinal hernias, 29 direct hernias, 1 femoral hernia, 1 pantaloon hernia (combined direct/indirect inguinal hernia), and 8 recurrent hernias after open anterior hernia repair.
The immediate postoperative outcomes as well as the short-term outcomes (mainly recurrence and incidence of chronic pain) were studied.
Results.
There was no conversion from TAPP repair to anterior open repair.
The mean operation time was 109 minutes (range, 40–132) for unilateral hernia repair.
Scrotal seroma was diagnosed at the operation site in 5 patients.
No patient had operation-related orchitis, testicle edema, trocar site infection, or chronic pain during follow-up.
Conclusions.
The use of Polysoft mesh for TAPP inguinal hernia repair does not seem to adversely affect the quality of repair.
The use of this mesh is therefore feasible and safe and may reduce postoperative pain.

Related Results

Groin hernia surgery in women : outputs, factors, methods and cost-effectiveness
Groin hernia surgery in women : outputs, factors, methods and cost-effectiveness
<p dir="ltr">There is inequity in access to surgical treatment and quality of care globally and this is more pronounced in low-and middle-income countries (LMICs) especially ...
Groin hernia surgery in women : outputs, factors, methods and cost-effectiveness
Groin hernia surgery in women : outputs, factors, methods and cost-effectiveness
<p dir="ltr">There is inequity in access to surgical treatment and quality of care globally and this is more pronounced in low-and middle-income countries (LMICs) especially ...
Evaluation of Mobility Status after Inguinal Hernia Surgery
Evaluation of Mobility Status after Inguinal Hernia Surgery
<b><i>Background:</i></b> Many different studies have compared open and laparoscopic-endoscopic inguinal hernia repair techniques according to intraoperativ...
AN EXPERIENCE COMPARING INGUINAL HERNIA MESH REPAIR VS DARN REPAIR
AN EXPERIENCE COMPARING INGUINAL HERNIA MESH REPAIR VS DARN REPAIR
Background: Several methods for fixing inguinal hernias have been documented. Anterior or posterior approaches,open or laparoscopic procedures, may be used for hernia repair. While...
Inguinal hernia: A hereditary disorder.
Inguinal hernia: A hereditary disorder.
Objective: To determine that inguinal hernia is an inherited disease running in families. Study Design: Prospective Observational. Setting: Surgical Unit I & III of Ghulam Moha...
Amyand's Hernia a form of Inguinal Hernia: A Case Report and Literature Review
Amyand's Hernia a form of Inguinal Hernia: A Case Report and Literature Review
Introduction: Amyand hernia (HA) is a form of inguinal hernia considered to be very rare, and this type of hernia has occurred up to 1% of all inguinal hernia cases. In this type o...
Groin hernia repair : evaluation of clinical impacts and interactions of mesh and mesh fixation
Groin hernia repair : evaluation of clinical impacts and interactions of mesh and mesh fixation
<p dir="ltr">AIMS</p><p dir="ltr">The project underlying this thesis aimed to identify and quantify relative risk differences in reoperation rate (Papers I and II...

Back to Top