Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Current-pumping performance of axial-symmetric superconducting dynamo designs

View through CrossRef
<p>In this project, the current pumping performances of three high temperature superconducting (HTS) dynamos (mechanically-rotating flux pumps) were investigated. These flux pumps (FPs) were identified as the Gen 1, Gen 2 and Gen 4 FP respectively. They were modelled using simple DC equivalent circuits and their performances were defined by three output parameters: DC open-circuit voltage (Voc), dynamic resistance (Rd) and DC short-circuit current (Isc). The experimental results showed that these FPs produced non-zero DC output voltages across their stators and each supplied DC output currents into series connected superconducting circuits.  The Gen 1 FP was cooled with liquid nitrogen and operated at 77 K. The stators were made from 12-mm wide copper-coated yttrium barium copper oxide (YBCO) HTS conductors. The objective of the experiment was to investigate the effect of the rotor magnet size, geometry and orientation (with respect to the stators) on the FP performance. The design parameters, based on the width and the length of the magnet with respect to the stator, for optimal FP performance were determined.  The Gen 2 FP was also cooled with liquid nitrogen and operated at 77 K. The stators were made from 46-mm wide Ag-coated YBCO HTS conductors. The objective of the experiment was to investigate the effect of stator width on the FP performance at various magnet frequencies. This was done by slitting two of the stators to form parallel stators with equal width, but smaller than the original conductor width. The experimental results showed that the FP performance was highly dependent on the operating frequency. Three operating frequency regimes were observed: low, mid and high. At high frequency, the Voc decreased and the Rd increased signifcantly. This was attributed to the local heating effect in the stator due to the increase in the current density. As a result, the FP produced zero output current in this regime. The AC voltage waveforms measured across the stators in different frequency regimes were very different in shapes and amplitudes. Therefore, these waveforms can be used to identify the operating frequency regime of the FP. At some operating frequencies in the mid frequency regime, bi-stable operating modes were observed, each mode resulted in different output parameters.  The Gen 4 FP was constructed in this project. It was cooled via thermal conduction method using a cryorefrigerator system. It had an axial-symmetric stator design where the shape of the stator is cylindrical. The width of the stator was considerably larger compared with the Gen 1 and Gen 2 FPs. The experiment objective was to investigate whether this design would produce a DC current, and then characterise the FP performance at different operating temperatures. The experimental results showed that the time-averaged DC output voltage of the Gen 4 FP was much higher compared with the Gen 1 and Gen 2 FPs. The reason is that it produced a DC output voltage for almost the entire rotor cycle. The experimental results also indicated that the Gen 4 FP has the capability to produce output currents in the kA range.</p>
Victoria University of Wellington Library
Title: Current-pumping performance of axial-symmetric superconducting dynamo designs
Description:
<p>In this project, the current pumping performances of three high temperature superconducting (HTS) dynamos (mechanically-rotating flux pumps) were investigated.
These flux pumps (FPs) were identified as the Gen 1, Gen 2 and Gen 4 FP respectively.
They were modelled using simple DC equivalent circuits and their performances were defined by three output parameters: DC open-circuit voltage (Voc), dynamic resistance (Rd) and DC short-circuit current (Isc).
The experimental results showed that these FPs produced non-zero DC output voltages across their stators and each supplied DC output currents into series connected superconducting circuits.
  The Gen 1 FP was cooled with liquid nitrogen and operated at 77 K.
The stators were made from 12-mm wide copper-coated yttrium barium copper oxide (YBCO) HTS conductors.
The objective of the experiment was to investigate the effect of the rotor magnet size, geometry and orientation (with respect to the stators) on the FP performance.
The design parameters, based on the width and the length of the magnet with respect to the stator, for optimal FP performance were determined.
  The Gen 2 FP was also cooled with liquid nitrogen and operated at 77 K.
The stators were made from 46-mm wide Ag-coated YBCO HTS conductors.
The objective of the experiment was to investigate the effect of stator width on the FP performance at various magnet frequencies.
This was done by slitting two of the stators to form parallel stators with equal width, but smaller than the original conductor width.
The experimental results showed that the FP performance was highly dependent on the operating frequency.
Three operating frequency regimes were observed: low, mid and high.
At high frequency, the Voc decreased and the Rd increased signifcantly.
This was attributed to the local heating effect in the stator due to the increase in the current density.
As a result, the FP produced zero output current in this regime.
The AC voltage waveforms measured across the stators in different frequency regimes were very different in shapes and amplitudes.
Therefore, these waveforms can be used to identify the operating frequency regime of the FP.
At some operating frequencies in the mid frequency regime, bi-stable operating modes were observed, each mode resulted in different output parameters.
  The Gen 4 FP was constructed in this project.
It was cooled via thermal conduction method using a cryorefrigerator system.
It had an axial-symmetric stator design where the shape of the stator is cylindrical.
The width of the stator was considerably larger compared with the Gen 1 and Gen 2 FPs.
The experiment objective was to investigate whether this design would produce a DC current, and then characterise the FP performance at different operating temperatures.
The experimental results showed that the time-averaged DC output voltage of the Gen 4 FP was much higher compared with the Gen 1 and Gen 2 FPs.
The reason is that it produced a DC output voltage for almost the entire rotor cycle.
The experimental results also indicated that the Gen 4 FP has the capability to produce output currents in the kA range.
</p>.

Related Results

Vortex pattern in three-dimensional mesoscopic superconducting rings
Vortex pattern in three-dimensional mesoscopic superconducting rings
Vortex structures in a mesoscopic a superconducting ring, which is in the magnetic field generated by a circular electric current, are investigated based on the phenomenological Gi...
Long-term dynamics of pesticide metabolites in soil and aquifers
Long-term dynamics of pesticide metabolites in soil and aquifers
Groundwater is one of the most important resources for drinking water, and has to be protected from the input of persistent substances. Nevertheless, pesticides and especially thei...
The Magnetic Helicity Driven Solar-Type Dynamo
The Magnetic Helicity Driven Solar-Type Dynamo
(1)The previous theoretical studies showed that the large-scale vorticity generate the divergent-type helicity flux from the magnetic fluctuations. Similarly to the $\alpha$ effect...
The Magnetic Helicity Driven Solar-Type Dynamo
The Magnetic Helicity Driven Solar-Type Dynamo
(1) Theoretical studies have shown that large-scale vorticity generates a divergent-type helicity flux associated with small-scale magnetic fluctuations. Similar to the α-effect, t...
Superconducting Proximity Effect in Magnetic Molecules
Superconducting Proximity Effect in Magnetic Molecules
<p>We studied the transport through magnetic molecules (MM) coupled to superconducting (S), ferromagnetic (F) and normal (N) leads, with the aim of investigating the interpla...
Establishment of Chassis Dynamometers for Commercial Vehicles
Establishment of Chassis Dynamometers for Commercial Vehicles
<div class="section abstract"><div class="htmlview paragraph">The Chassis Dynamo-meter system provides a means of testing vehicle in place of driving them on the test t...
New constraint of the Martian dynamo from surface magnetic survey by Zhurong rover
New constraint of the Martian dynamo from surface magnetic survey by Zhurong rover
The timing of the martian dynamo has always been an outstanding scientific issue in the evolution of Mars, as it provides the key implications for the evolution of the Martian core...

Back to Top