Javascript must be enabled to continue!
Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer
View through CrossRef
AbstractMiniature gas chromatography (GC) and miniature mass spectrometry (MS) instrumentation has been developed to identify and quantify the chemical compounds present in complex mixtures of gases. The design approach utilizes micro‐GC components coupled with a Paul quadrupole ion trap (QIT) mass spectrometer. Inherent to the system are high sensitivity, good dynamic range, good QIT resolution, low GC flow‐rates to minimize vacuum requirements and the need for consumables; and the use of a modular approach to adapt to volatile organic compounds dissolved in water or present in sediment. Measurements are reported on system response to gaseous species at concentrations varying over four orders of magnitude. The ability of the system to deal with complicated mixtures is demonstrated, and future improvements are discussed. The GC/QIT system described herein has a mass, volume and power that are, conservatively, one‐twentieth of those of commercial off‐the‐shelf systems. Potential applications are to spacecraft cabin‐air monitoring, robotic planetary exploration and trace‐species detection for residual gas analysis and environmental monitoring. Copyright © 2004 John Wiley & Sons, Ltd.
Title: Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer
Description:
AbstractMiniature gas chromatography (GC) and miniature mass spectrometry (MS) instrumentation has been developed to identify and quantify the chemical compounds present in complex mixtures of gases.
The design approach utilizes micro‐GC components coupled with a Paul quadrupole ion trap (QIT) mass spectrometer.
Inherent to the system are high sensitivity, good dynamic range, good QIT resolution, low GC flow‐rates to minimize vacuum requirements and the need for consumables; and the use of a modular approach to adapt to volatile organic compounds dissolved in water or present in sediment.
Measurements are reported on system response to gaseous species at concentrations varying over four orders of magnitude.
The ability of the system to deal with complicated mixtures is demonstrated, and future improvements are discussed.
The GC/QIT system described herein has a mass, volume and power that are, conservatively, one‐twentieth of those of commercial off‐the‐shelf systems.
Potential applications are to spacecraft cabin‐air monitoring, robotic planetary exploration and trace‐species detection for residual gas analysis and environmental monitoring.
Copyright © 2004 John Wiley & Sons, Ltd.
Related Results
Linear ion traps in mass spectrometry
Linear ion traps in mass spectrometry
Abstract
I.
Introduction
000
II.
Linear Multipoles
000
A. Multipole Fields
000
1. Multipole Potentials
000
2. Ion Motion in 2D Multipole Fields
000...
Keanekaragaman Serangga Yang Berpotensi Hama Di Hutan Pendidikan Universitas Jambi
Keanekaragaman Serangga Yang Berpotensi Hama Di Hutan Pendidikan Universitas Jambi
ABSTRACT
This research is to identify the types of insect pests with four trapping methods, there are Sweep Net Trap, Pit Fall Trap, Yellow Paper Trap, and Light Trap. This researc...
The Black Mass as Play: Dennis Wheatley's The Devil Rides Out
The Black Mass as Play: Dennis Wheatley's The Devil Rides Out
Literature—at least serious literature—is something that we work at. This is especially true within the academy. Literature departments are places where workers labour over texts c...
Diels–Alder reactions of mass‐selected ions in an ion trap mass spectrometer
Diels–Alder reactions of mass‐selected ions in an ion trap mass spectrometer
AbstractThis Communication describes the use of a bench‐top ion trap mass spectrometer for the study of structurally diagnostic ion/molecule reactions. The power of the experiment ...
Simulation of unidirectional ion ejection in linear ion traps with asymmetric radiofrequency voltage
Simulation of unidirectional ion ejection in linear ion traps with asymmetric radiofrequency voltage
RationaleLinear ion traps with simplified structure have been widely used in miniaturized mass spectrometers. However, linear ion traps usually have low ion detection efficiency wh...
Optimization and simulation of MEMS rectilinear ion trap
Optimization and simulation of MEMS rectilinear ion trap
In this paper, the design of a MEMS rectilinear ion trap was optimized under simulated conditions. The size range of the MEMS rectilinear ion trap’s electrodes studied in this pape...
Exploring The Co-composting Potentials of Raw Grease Trap and Grease Trap-Derived Soaps: Insights into Grease Trap Modification, Calcium Supplementation, and Microbial Community Analysis
Exploring The Co-composting Potentials of Raw Grease Trap and Grease Trap-Derived Soaps: Insights into Grease Trap Modification, Calcium Supplementation, and Microbial Community Analysis
Managing waste with grease traps poses a challenge because of the potential environmental issues associated with its disposal. In this study, two approaches were investigated to in...
Otomatisasi Flame Trap Berbasis Sistem Pneumatik Pada Kendaraan Pengangkut BBM
Otomatisasi Flame Trap Berbasis Sistem Pneumatik Pada Kendaraan Pengangkut BBM
Abstrak - Flame trap merupakan sebuah perangkat yang dipasang pada knalpot mobil tangki bahan bakar minyak (BBM) dengan bertujuan untuk mencegah terjadinya percikan api yang ditimb...

