Javascript must be enabled to continue!
Task-evoked pulse wave amplitude tracks cognitive load
View through CrossRef
Abstract
Cognitive load is a crucial factor in mentally demanding activities and holds significance across various research fields. This study aimed to investigate the effectiveness of pulse wave amplitude (PWA) as a measure for tracking cognitive load and associated mental effort in comparison to heart rate (HR) during a digit span task. The data from 78 participants were included in the analyses. Participants performed a memory task in which they were asked to memorize sequences of 5, 9, or 13 digits, and a control task where they passively listened to the sequences. PWA and HR were quantified from photoplethysmography (PPG) and electrocardiography (ECG), respectively. Pupil dilation was also assessed as a measure of cognitive load. We found that PWA showed a strong suppression with increasing memory load, indicating sensitivity to cognitive load. In contrast, HR did not show significant changes with task difficulty. Moreover, when memory load exceeded the capacity of working memory, a reversal of the PWA pattern was observed, indicating cognitive overload. In this respect, changes in PWA in response to cognitive load correlated with the dynamics of pupil dilation, suggesting a potential shared underlying mechanism. Additionally, both HR and PWA demonstrated a relationship with behavioral performance, with higher task-evoked HR and lower PWA associated with better memory performance. Our findings suggest that PWA is a more sensitive measure than HR for tracking cognitive load and overload. PWA, measured through PPG, holds significant potential for practical applications in assessing cognitive load due to its ease of use and sensitivity to cognitive overload. The findings contribute to the understanding of psychophysiological indicators of cognitive load and offer insights into the use of PWA as a non-invasive measure in various contexts.
Title: Task-evoked pulse wave amplitude tracks cognitive load
Description:
Abstract
Cognitive load is a crucial factor in mentally demanding activities and holds significance across various research fields.
This study aimed to investigate the effectiveness of pulse wave amplitude (PWA) as a measure for tracking cognitive load and associated mental effort in comparison to heart rate (HR) during a digit span task.
The data from 78 participants were included in the analyses.
Participants performed a memory task in which they were asked to memorize sequences of 5, 9, or 13 digits, and a control task where they passively listened to the sequences.
PWA and HR were quantified from photoplethysmography (PPG) and electrocardiography (ECG), respectively.
Pupil dilation was also assessed as a measure of cognitive load.
We found that PWA showed a strong suppression with increasing memory load, indicating sensitivity to cognitive load.
In contrast, HR did not show significant changes with task difficulty.
Moreover, when memory load exceeded the capacity of working memory, a reversal of the PWA pattern was observed, indicating cognitive overload.
In this respect, changes in PWA in response to cognitive load correlated with the dynamics of pupil dilation, suggesting a potential shared underlying mechanism.
Additionally, both HR and PWA demonstrated a relationship with behavioral performance, with higher task-evoked HR and lower PWA associated with better memory performance.
Our findings suggest that PWA is a more sensitive measure than HR for tracking cognitive load and overload.
PWA, measured through PPG, holds significant potential for practical applications in assessing cognitive load due to its ease of use and sensitivity to cognitive overload.
The findings contribute to the understanding of psychophysiological indicators of cognitive load and offer insights into the use of PWA as a non-invasive measure in various contexts.
Related Results
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
Objectives
To investigate the relationship between atrial fibrillation cardioversion and f wave in electrocardiogram, providing an ordinary and noninvasive method...
Hurricane Eloise Directional Wave Energy Spectra
Hurricane Eloise Directional Wave Energy Spectra
ABSTRACT
Directiona1 wave energy spectra, calculated from data recorded during Hurricane Eloise (Gulf of Mexico, 1975), are presented. The spectra, based on an en...
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when e...
Wave Force Calculations for Stokes and Non-Stokes Waves
Wave Force Calculations for Stokes and Non-Stokes Waves
ABSTRACT
A new wave particle velocity procedure permits calculation of forces from regular wave profiles of more or less arbitrary wave crest to height ratios, as...
On etching, selection and measurement of confined fission tracks in apatite
On etching, selection and measurement of confined fission tracks in apatite
Abstract. This work investigates the selection of horizontal confined tracks for fission-track modelling. It is carried out on prism sections of Durango apatite containing induced ...
Multivariate characterization of wave storms in coastal areas
Multivariate characterization of wave storms in coastal areas
Wave-storms are the responsible of the main changes in the Coast. Their detailed characterization results in a better design of any marine structure. The most common approach to de...
Extraction method of wide‐band phased array radar signals based on pulse amplitude characteristic
Extraction method of wide‐band phased array radar signals based on pulse amplitude characteristic
Wide‐band phased array radar is the primary focus in electronic countermeasure reconnaissance, and prior extraction of such radar signals in the interleaved pulse data intercepted ...
Crane Load Moment System For Offshore Crane Operations
Crane Load Moment System For Offshore Crane Operations
Abstract
History has shown that dependency upon the crane operator to monitor loads and boom angle or load radius do not allow the margin necessary to perform the...

