Volar Scaphoid Plating for Nonunion: A Multicenter Case Series Study

View through CrossRef
Abstract Background The volar scaphoid plate from Medartis (Medartis AG, Austrasse, Basel, Switzerland) is a variable angle titanium locking plate, preformed for the volar aspect of the scaphoid. It does not have compressive capability, and may act as a bridging device. It may provide an advantage over a compression screw where the pathoanatomy is less favorable to such a device with increased rotational stability. It may act as a buttress plate for correction of humpback deformity for example. It has been used in nonunions and with vascularized grafts. Questions Our study aims to assess the results of our patients with scaphoid nonunion treated with scaphoid volar plating over a larger number of patients. We aim to identify techniques to increase the success of plating. Methods Patients from our cohort were retrospectively reviewed. Operations were performed by three hand fellowship trained surgeons and in two centers. Inclusion involved a scaphoid plate procedure for a nonunion of the scaphoid with a minimum of 6 months of follow-up. Exclusions were those who had less than 6 months of follow-up. Data included demographics, patient-rated wrist evaluation (PRWE), a quick disabilities of the arm, shoulder, and hand (qDASH), visual analogue score, and range and grip. Radiology was reviewed. Results Thirty-two eligible patients were assessed. The mean age was 25 years (range 13–46), 2 were female and 15 were smokers. Mean follow-up postsurgery was 18 months. Twenty-nine of 32 patients united (90.6%) on computed tomography scan. Clinical assessment was performed in the 25 patients. The mean qDASH score was 12.5 (range 0–42) and mean PRWE was 11 (range 0–54). The mean arc of motion was 115 degrees. The mean grip strength was 39 kg compared with 41 kg on the nonoperated side. Conclusion We postulate that the plate acts like an internal bridging device, acting over a small distance, and inherent stability of the construct with structural graft and accurate reduction prior to plating is advantageous. Potential problems include plate impingement on the volar lip of the radius, particularly when trying to plate more proximal fractures. Ideally, it is utilized for mid to distal waist fractures.
Title: Volar Scaphoid Plating for Nonunion: A Multicenter Case Series Study
Description:
Abstract Background The volar scaphoid plate from Medartis (Medartis AG, Austrasse, Basel, Switzerland) is a variable angle titanium locking plate, preformed for the volar aspect of the scaphoid.
It does not have compressive capability, and may act as a bridging device.
It may provide an advantage over a compression screw where the pathoanatomy is less favorable to such a device with increased rotational stability.
It may act as a buttress plate for correction of humpback deformity for example.
It has been used in nonunions and with vascularized grafts.
Questions Our study aims to assess the results of our patients with scaphoid nonunion treated with scaphoid volar plating over a larger number of patients.
We aim to identify techniques to increase the success of plating.
Methods Patients from our cohort were retrospectively reviewed.
Operations were performed by three hand fellowship trained surgeons and in two centers.
Inclusion involved a scaphoid plate procedure for a nonunion of the scaphoid with a minimum of 6 months of follow-up.
Exclusions were those who had less than 6 months of follow-up.
Data included demographics, patient-rated wrist evaluation (PRWE), a quick disabilities of the arm, shoulder, and hand (qDASH), visual analogue score, and range and grip.
Radiology was reviewed.
Results Thirty-two eligible patients were assessed.
The mean age was 25 years (range 13–46), 2 were female and 15 were smokers.
Mean follow-up postsurgery was 18 months.
Twenty-nine of 32 patients united (90.
6%) on computed tomography scan.
Clinical assessment was performed in the 25 patients.
The mean qDASH score was 12.
5 (range 0–42) and mean PRWE was 11 (range 0–54).
The mean arc of motion was 115 degrees.
The mean grip strength was 39 kg compared with 41 kg on the nonoperated side.
Conclusion We postulate that the plate acts like an internal bridging device, acting over a small distance, and inherent stability of the construct with structural graft and accurate reduction prior to plating is advantageous.
Potential problems include plate impingement on the volar lip of the radius, particularly when trying to plate more proximal fractures.
Ideally, it is utilized for mid to distal waist fractures.

Related Results

Scaphoid nonunion and SNAC treatment
Scaphoid nonunion and SNAC treatment
Introduction Scaphoid nonunion can result in progressive scaphoid nonunion advanced collapse (SNAC) and  have an impact on the quality of life in younger patients. The social signi...
Percutaneous Fixation for Scaphoid Nonunion With Bone Grafting Through the Distal Insertion Hole of a Fully Threaded Headless Screw
Percutaneous Fixation for Scaphoid Nonunion With Bone Grafting Through the Distal Insertion Hole of a Fully Threaded Headless Screw
Objective: Percutaneous scaphoid screw fixation is a popular treatment for acute scaphoid fractures with no or minimal displacement. For treating scaphoid nonunions, however, open ...
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
Abstract Objective: The aim of this study was to present a technique that allows the surgeon to easily and reliably achieve volar tilt in dorsally displaced distal radius fract...
Functional Outcome of Volar Barton Fracture of Distal End Radius Undergoing Plating
Functional Outcome of Volar Barton Fracture of Distal End Radius Undergoing Plating
Background: Volar Barton fractures of the distal radius are complex intra-articular injuries that often require surgical intervention for optimal functional recovery. Volar plating...
Volar Vascularized Strut Graft for Avascular Scaphoid Nonunion Using the 1,2 Intercompartmental Supraretinacular Artery
Volar Vascularized Strut Graft for Avascular Scaphoid Nonunion Using the 1,2 Intercompartmental Supraretinacular Artery
In this retrospective study, we report the preliminary results of a novel technique for volar vascularized strut grafting to treat avascular scaphoid nonunion by using the 1,2 inte...

Back to Top