Javascript must be enabled to continue!
Preparation and Electronic Properties of YBa2Cu3OxFilms with Controlled Oxygen Stoichiometries
View through CrossRef
We describe a novel technique capable of controlling the oxygen content of YBa2Cu3Ox(YBCO) films in a precise and reversible manner. The temperature dependence of resistivity and the distinct two-plateau behavior in critical temperatureTcoversus oxygen content plot of these films are consistent with those observed in the bulk and single crystals of YBCO. The O 1sand Cu 2pabsorption spectra of these films were measured by polarization-dependent X-ray absorption spectroscopy (XAS). The intensity variations of the pre-edge peaks as a function of oxygen content are discussed. We also used these films to systematically study the electron-phonon coupling strength and the position of Fermi level by using a femtosecond pump-probe technique. A clear sign-reversal of the transient reflectivity, which was consistently explained by the thermomodulation model, was observed. Both of these optical measurements support the idea that the electronic structure of YBCO cuprates is based on the charge transfer model with hybridization between the Cu and O sites.
IOP Publishing
Kaung-Hsiung Wu Kaung-Hsiung Wu
Ming-Chih Hsieh Ming-Chih Hsieh
Shih-Pu Chen Shih-Pu Chen
Shyh-Chin Chao Shyh-Chin Chao
Jenh-Yih Juang Jenh-Yih Juang
Tseng-Ming Uen Tseng-Ming Uen
Yih-Shung Gou Yih-Shung Gou
Tseung-Yuen Tseng Tseung-Yuen Tseng
Chao-Ming Fu Chao-Ming Fu
Jin-Ming Chen Jin-Ming Chen
Ru-Gun Liu Ru-Gun Liu
Title: Preparation and Electronic Properties of YBa2Cu3OxFilms with Controlled Oxygen Stoichiometries
Description:
We describe a novel technique capable of controlling the oxygen content of YBa2Cu3Ox(YBCO) films in a precise and reversible manner.
The temperature dependence of resistivity and the distinct two-plateau behavior in critical temperatureTcoversus oxygen content plot of these films are consistent with those observed in the bulk and single crystals of YBCO.
The O 1sand Cu 2pabsorption spectra of these films were measured by polarization-dependent X-ray absorption spectroscopy (XAS).
The intensity variations of the pre-edge peaks as a function of oxygen content are discussed.
We also used these films to systematically study the electron-phonon coupling strength and the position of Fermi level by using a femtosecond pump-probe technique.
A clear sign-reversal of the transient reflectivity, which was consistently explained by the thermomodulation model, was observed.
Both of these optical measurements support the idea that the electronic structure of YBCO cuprates is based on the charge transfer model with hybridization between the Cu and O sites.
Related Results
High Concentration Oxygen and Hypercapnia in Respiratory Disease
High Concentration Oxygen and Hypercapnia in Respiratory Disease
<p>Oxygen-induced elevations in arterial carbon dioxide tension have been demonstrated in patients with chronic obstructive pulmonary disease (COPD), asthma, pneumonia, obesi...
Closed-Loop Oxygen Control
Closed-Loop Oxygen Control
<p>Guidelines recommend that oxygen should be titrated to achieve a target oxygen saturation (SpO2 ) range in acutely unwell patients, a concept colloquially known as “swimmi...
C:N:P stoichiometric variations of herbs and its relationships with soil properties and species relative abundance along the Xiaokai River irrigation in the Yellow River Delta, China
C:N:P stoichiometric variations of herbs and its relationships with soil properties and species relative abundance along the Xiaokai River irrigation in the Yellow River Delta, China
IntroductionSoil salinity is known to affect plant performance and nutrient stoichiometry by altering their ecophysiology, and thus playing a crucial role in determining plant dist...
Myoglobin-enhanced oxygen delivery to isolated cardiac mitochondria
Myoglobin-enhanced oxygen delivery to isolated cardiac mitochondria
SUMMARYThe heart, red skeletal muscles and the nitrogen-fixing legume root nodule function in steady states of high oxygen influx, partial oxygenation of cytoplasmic myoglobin or l...
Development of Portable Oxygen Concentrator - A Review
Development of Portable Oxygen Concentrator - A Review
The Covid-19 Pandemic, with its first ever reported case in the Wuhan province of China in the year 2019, has led to a newfound global demand for Medical Oxygen supply at a sudden ...
Oxygen Toxicity
Oxygen Toxicity
In a broad sense, if the oxygen partial pressure is higher than the oxygen partial pressure at atmospheric pressure (21kPa), they can be called high partial pressure oxygen or hype...
Myoglobin function reassessed
Myoglobin function reassessed
SUMMARYThe heart and those striated muscles that contract for long periods, having available almost limitless oxygen, operate in sustained steady states of low sarcoplasmic oxygen ...
The Design of Oxygen Concentration and Flowrate in CPAP
The Design of Oxygen Concentration and Flowrate in CPAP
Measuring oxygen concentration and measuring the flow of oxygen is a tool used to measure the percentage of oxygen content and oxygen flow rate in CPAP. This tool uses the OCS-03F ...

