Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

EVALUASI PERFORMANCE LEAD APRON

View through CrossRef
Background : Lead apron is the most important part of set protection radiation personal in Radiology Instalation. Lead apron in Radiology instalation Roemani Muhammadiyah Semarang hospital had been test on 2014. But there is no test after that. The testing standard is 12-18 months at once or when it is needed, so this time the test should be done. This aim of the research are to  know physical condition, lead apron profile, treatment and maintenance of lead apron, the result of the test and worthyness of lead apron. Methods: The Type of this research is quantitative research with survey approach. Research use observation, testing, measuring and documentation. Observation done immediately toward the lead apron condition. Lead apron test also done by ilumination of all lead apron surface use x-ray machine. The data from this research then checked with measuring crease, torn, crack, hole and inequality colour use software in computed radiography and desribed later. Result: The result of the research indicate that the Lead Apron number 1 and 2 have bad condition and crack more than 15mm2  in vital organ and more than 670 mm2  in non vital organ. Lead Apron number 3,4,5 have good condition, but has creases and some Lead Apron have inequality colour, Lead Apron number 6 has crease that cause a torn, but still in normal criteria. Lead Apron number 7 has a good condition with not crease. Conclution: Two out of seven Lead Apron are declared not appropriate, dan five out of seven Lead Apron are declared appropriate, further can created Amount of Appropriate Lead Apron percentage which is five lead apron (71%) in appropriate condition and two lead apron (29%) in not appropriate condition.  
Title: EVALUASI PERFORMANCE LEAD APRON
Description:
Background : Lead apron is the most important part of set protection radiation personal in Radiology Instalation.
Lead apron in Radiology instalation Roemani Muhammadiyah Semarang hospital had been test on 2014.
But there is no test after that.
The testing standard is 12-18 months at once or when it is needed, so this time the test should be done.
This aim of the research are to  know physical condition, lead apron profile, treatment and maintenance of lead apron, the result of the test and worthyness of lead apron.
Methods: The Type of this research is quantitative research with survey approach.
Research use observation, testing, measuring and documentation.
Observation done immediately toward the lead apron condition.
Lead apron test also done by ilumination of all lead apron surface use x-ray machine.
The data from this research then checked with measuring crease, torn, crack, hole and inequality colour use software in computed radiography and desribed later.
Result: The result of the research indicate that the Lead Apron number 1 and 2 have bad condition and crack more than 15mm2  in vital organ and more than 670 mm2  in non vital organ.
Lead Apron number 3,4,5 have good condition, but has creases and some Lead Apron have inequality colour, Lead Apron number 6 has crease that cause a torn, but still in normal criteria.
Lead Apron number 7 has a good condition with not crease.
Conclution: Two out of seven Lead Apron are declared not appropriate, dan five out of seven Lead Apron are declared appropriate, further can created Amount of Appropriate Lead Apron percentage which is five lead apron (71%) in appropriate condition and two lead apron (29%) in not appropriate condition.
 .

Related Results

Evaluasi Kapasitas Apron Utara Bandar Udara Internasional I Gusti Ngurah Rai Bali
Evaluasi Kapasitas Apron Utara Bandar Udara Internasional I Gusti Ngurah Rai Bali
The apron capacity of I Gusti Ngurah Rai International Airport is an important factor in handling the increasing number of aircraft movements. This research utilizes the FAA (Feder...
PENGEMBANGAN EVALUASI PEMBELAJARAN
PENGEMBANGAN EVALUASI PEMBELAJARAN
Dalam sebuah proses pembelajaran komponen yang turut menentukan keberhasilan sebuah proses adalah evaluasi. Melalui evaluasi orang akan mengetahui sampai sejauh mana penyampaian pe...
Optimizations of Aircraft Parking Capacity (Apron) in Minangkabau International Airport Padang
Optimizations of Aircraft Parking Capacity (Apron) in Minangkabau International Airport Padang
Minangkabau International Airport has one apron and one hangar. Apron has 7 parking stands with number of parking stand are 1, 2, 3, 4, 5, 6A, and 7. Parking stands 1 and 7 are ded...
Management of Covered Kernel Smut (Sporisorium sorghi) Disease of Sorghum (Sorghum bicolor) at Gabilley District in Somaliland
Management of Covered Kernel Smut (Sporisorium sorghi) Disease of Sorghum (Sorghum bicolor) at Gabilley District in Somaliland
Sorghum is multi-purpose crop that plays an important role in the socio-economic life of farming communities in Somaliland. However its production and productivity is threatened du...
Joint Rapid Airfield Construction (JRAC) Program 2004 Demonstration Project--Fort Bragg, North Carolina
Joint Rapid Airfield Construction (JRAC) Program 2004 Demonstration Project--Fort Bragg, North Carolina
This report describes the demonstration of technologies and procedures developed during April 2002 and May 2004 under the Joint Rapid Airfield Construction (JRAC) Program. The demo...
Mencegah Stop Raw Mill Akibat Kerusakan Head Shaft Apron Conveyor 332-AC1
Mencegah Stop Raw Mill Akibat Kerusakan Head Shaft Apron Conveyor 332-AC1
Raw Mill merupakan equipment dalam proses pembuatan semen yang digunakan untuk menghaluskan bahan baku (limestone, clay, silica sand, & iron ore). Raw Mill tidak dapat beropera...
Penilaian Keberhasilan Dan Bentuk Evaluasi Keperawatan
Penilaian Keberhasilan Dan Bentuk Evaluasi Keperawatan
Latar Belakang : perawat perlu melakukan tahap evaluasi pada proses keperawatan untuk menilai keberhasilan dari tahapan proses keperawatan yang sebelumnya dilakukan, dalam melakuk...

Back to Top