Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

EVALUASI PERFORMANCE LEAD APRON

View through CrossRef
Background : Lead apron is the most important part of set protection radiation personal in Radiology Instalation. Lead apron in Radiology instalation Roemani Muhammadiyah Semarang hospital had been test on 2014. But there is no test after that. The testing standard is 12-18 months at once or when it is needed, so this time the test should be done. This aim of the research are to  know physical condition, lead apron profile, treatment and maintenance of lead apron, the result of the test and worthyness of lead apron. Methods: The Type of this research is quantitative research with survey approach. Research use observation, testing, measuring and documentation. Observation done immediately toward the lead apron condition. Lead apron test also done by ilumination of all lead apron surface use x-ray machine. The data from this research then checked with measuring crease, torn, crack, hole and inequality colour use software in computed radiography and desribed later. Result: The result of the research indicate that the Lead Apron number 1 and 2 have bad condition and crack more than 15mm2  in vital organ and more than 670 mm2  in non vital organ. Lead Apron number 3,4,5 have good condition, but has creases and some Lead Apron have inequality colour, Lead Apron number 6 has crease that cause a torn, but still in normal criteria. Lead Apron number 7 has a good condition with not crease. Conclution: Two out of seven Lead Apron are declared not appropriate, dan five out of seven Lead Apron are declared appropriate, further can created Amount of Appropriate Lead Apron percentage which is five lead apron (71%) in appropriate condition and two lead apron (29%) in not appropriate condition.  
Title: EVALUASI PERFORMANCE LEAD APRON
Description:
Background : Lead apron is the most important part of set protection radiation personal in Radiology Instalation.
Lead apron in Radiology instalation Roemani Muhammadiyah Semarang hospital had been test on 2014.
But there is no test after that.
The testing standard is 12-18 months at once or when it is needed, so this time the test should be done.
This aim of the research are to  know physical condition, lead apron profile, treatment and maintenance of lead apron, the result of the test and worthyness of lead apron.
Methods: The Type of this research is quantitative research with survey approach.
Research use observation, testing, measuring and documentation.
Observation done immediately toward the lead apron condition.
Lead apron test also done by ilumination of all lead apron surface use x-ray machine.
The data from this research then checked with measuring crease, torn, crack, hole and inequality colour use software in computed radiography and desribed later.
Result: The result of the research indicate that the Lead Apron number 1 and 2 have bad condition and crack more than 15mm2  in vital organ and more than 670 mm2  in non vital organ.
Lead Apron number 3,4,5 have good condition, but has creases and some Lead Apron have inequality colour, Lead Apron number 6 has crease that cause a torn, but still in normal criteria.
Lead Apron number 7 has a good condition with not crease.
Conclution: Two out of seven Lead Apron are declared not appropriate, dan five out of seven Lead Apron are declared appropriate, further can created Amount of Appropriate Lead Apron percentage which is five lead apron (71%) in appropriate condition and two lead apron (29%) in not appropriate condition.
 .

Related Results

Evaluasi Kapasitas Apron Utara Bandar Udara Internasional I Gusti Ngurah Rai Bali
Evaluasi Kapasitas Apron Utara Bandar Udara Internasional I Gusti Ngurah Rai Bali
The apron capacity of I Gusti Ngurah Rai International Airport is an important factor in handling the increasing number of aircraft movements. This research utilizes the FAA (Feder...
THE IMPACT OF CLOSED CIRCUIT TELEVISION ADDITION ON APRON MOVEMENT CONTROL SUPERVISION IN APRON C JUANDA AIRPORT
THE IMPACT OF CLOSED CIRCUIT TELEVISION ADDITION ON APRON MOVEMENT CONTROL SUPERVISION IN APRON C JUANDA AIRPORT
This Final Project which discusses the impact of Closed Circuit Television Addition on Apron Movement Control Supervision in Apron C Juanda Airport. This is motivated by the limite...
Analisis Kinerja Personil Apron Movement Control Dalam Meningkatkan Keselamatan Penerbangan Kualanamu Medan
Analisis Kinerja Personil Apron Movement Control Dalam Meningkatkan Keselamatan Penerbangan Kualanamu Medan
Apron Movement Control  adalah unit yang bertanggung jawab untuk mengatur dan mengawasi semua kegiatan di apron mulai dari penempatan pesawat (parking), mengawasi proses pengisian ...
Uji Kelayakan Alat Pelindung diri Lead Apron di Instalasi Radiologi Rumah Sakit Daerah Mangusada Badung
Uji Kelayakan Alat Pelindung diri Lead Apron di Instalasi Radiologi Rumah Sakit Daerah Mangusada Badung
Lead apron is a type of personal protective equipment in the form of an apron and made of lead which is designed to protect the body from the dangers of radiation. Menurut Keputusa...
PENGEMBANGAN EVALUASI PEMBELAJARAN
PENGEMBANGAN EVALUASI PEMBELAJARAN
Dalam sebuah proses pembelajaran komponen yang turut menentukan keberhasilan sebuah proses adalah evaluasi. Melalui evaluasi orang akan mengetahui sampai sejauh mana penyampaian pe...
Enhancing Airport Apron Safety Through Intelligent Transportation Systems: Proposed Feda Model
Enhancing Airport Apron Safety Through Intelligent Transportation Systems: Proposed Feda Model
The safe operation of an airport apron is a vital part of aviation safety. The fact that accidents and incidents are still experienced in aviation indicates that safety is still an...

Back to Top