Javascript must be enabled to continue!
An Interesting Observation Regarding Retrograde Vertebral Artery Flow in Patients With Dialysis Access Fistulas
View through CrossRef
ObjectivesRetrograde vertebral artery flow, the steal phenomenon, is most frequently caused by a flow‐limiting stenosis of the proximal subclavian artery. The reversal of flow can be incomplete, resulting in bidirectional flow: retrograde in systole and antegrade in diastole. Less often, retrograde vertebral artery flow is the consequence of increased subclavian flow, as might occur with a well‐functioning dialysis access fistula. Our objective was to evaluate bidirectional vertebral artery flow associated with dialysis access fistulas.MethodsWe retrospectively reviewed the direction of flow through the vertebral artery in systole and diastole of 335 patients with dialysis fistulas who had undergone extracranial cerebral vascular Doppler examinations.ResultsFifteen patients had retrograde flow in their vertebral artery ipsilateral with the side of their fistula. There was completely reversed flow in 1 patient and bidirectional flow in the other 14. For each of these 14, the flow was antegrade in early systole and retrograde in diastole. Compression of the fistula restored the antegrade flow.ConclusionsUnder conditions of reduced subclavian artery flow, bidirectional vertebral artery flow will be retrograde in early systole and antegrade in diastole. Under conditions of increased subclavian artery flow, bidirectional flow through the vertebral artery will be antegrade in early systole and retrograde in diastole.
Title: An Interesting Observation Regarding Retrograde Vertebral Artery Flow in Patients With Dialysis Access Fistulas
Description:
ObjectivesRetrograde vertebral artery flow, the steal phenomenon, is most frequently caused by a flow‐limiting stenosis of the proximal subclavian artery.
The reversal of flow can be incomplete, resulting in bidirectional flow: retrograde in systole and antegrade in diastole.
Less often, retrograde vertebral artery flow is the consequence of increased subclavian flow, as might occur with a well‐functioning dialysis access fistula.
Our objective was to evaluate bidirectional vertebral artery flow associated with dialysis access fistulas.
MethodsWe retrospectively reviewed the direction of flow through the vertebral artery in systole and diastole of 335 patients with dialysis fistulas who had undergone extracranial cerebral vascular Doppler examinations.
ResultsFifteen patients had retrograde flow in their vertebral artery ipsilateral with the side of their fistula.
There was completely reversed flow in 1 patient and bidirectional flow in the other 14.
For each of these 14, the flow was antegrade in early systole and retrograde in diastole.
Compression of the fistula restored the antegrade flow.
ConclusionsUnder conditions of reduced subclavian artery flow, bidirectional vertebral artery flow will be retrograde in early systole and antegrade in diastole.
Under conditions of increased subclavian artery flow, bidirectional flow through the vertebral artery will be antegrade in early systole and retrograde in diastole.
Related Results
Assessment of implementation of the Pradhan Mantri national dialysis Programme in Hospitals in Delhi
Assessment of implementation of the Pradhan Mantri national dialysis Programme in Hospitals in Delhi
Background: Annual-demand for haemodialysis-sessions in India is 3.4 Crores. To make Renal-care-services affordable to APL and free to BPL, Ministry of Health and Family Welfare la...
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Factors Associated With Dialysis Withdrawal In Dialysis Patients
Factors Associated With Dialysis Withdrawal In Dialysis Patients
Abstract
Background: Research on the factors associated with dialysis withdrawal in dialysis patients has been limited. Authors have used different definitions for dialysis...
FC 117TIME TRENDS IN PROBABILITY OF STARTING HOME DIALYSIS OVER A 20 YEAR PERIOD: A DUTCH REGISTRY STUDY
FC 117TIME TRENDS IN PROBABILITY OF STARTING HOME DIALYSIS OVER A 20 YEAR PERIOD: A DUTCH REGISTRY STUDY
Abstract
Background and Aims
A growing number of patients suffers from End Stage Kidney Disease(ESKD), causing a logistical and ...
Percutaneous Endovascular Treatment of Stenosis of Dialysis Arteriovenous Fistulas
Percutaneous Endovascular Treatment of Stenosis of Dialysis Arteriovenous Fistulas
Background: The incidence of end stage renal disease is on the rise and most of these patients are undergoing dialysis either through tunneled/non tunneled dialysis catheters or th...
Abstract Number ‐ 248: Association Between Vertebrobasilar Stenosis, Location, and Quantitative Magnetic Resonance Angiography Flow State
Abstract Number ‐ 248: Association Between Vertebrobasilar Stenosis, Location, and Quantitative Magnetic Resonance Angiography Flow State
Introduction
The relationship between the degree of vertebrobasilar stenosis and QMRA distal‐flow status is uncertain. Our aim was to investigate this relationship.
...
MO702DIFFERENCES IN HOSPITALISATION BETWEEN PERITONEAL DIALYSIS AND IN-CENTRE HAEMODIALYSIS PATIENTS
MO702DIFFERENCES IN HOSPITALISATION BETWEEN PERITONEAL DIALYSIS AND IN-CENTRE HAEMODIALYSIS PATIENTS
Abstract
Background and Aims
End stage kidney disease (ESKD) and dialysis treatment are associated with high morbidity, frequent...
An Overview of Regular Dialysis Treatment in Japan as of 31 December 2003
An Overview of Regular Dialysis Treatment in Japan as of 31 December 2003
Abstract: A statistical survey of 3750 nationwide dialysis facilities was carried out by the Japanese Society for Dialysis Therapy (JSDT) at the end of 2003, with answers to the qu...

