Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Reversible and irreversible electroporation of cell suspensions flowing through a localized DC electric field

View through CrossRef
AbstractExperiments on reversible and irreversible cell electroporation were carried out with an experimental setup based on a standard apparatus for horizontal electrophoresis, a syringe pump with regulated cell suspension flow velocity and a dcEF power supply. Cells in suspension flowing through an orifice in a barrier inserted into the electrophoresis apparatus were exposed to defined localized dcEFs in the range of 0–1000 V/cm for a selected duration in the range 10–1000 ms. This method permitted the determination of the viability of irreversibly electroperforated cells. It also showed that the uptake by reversibly electroperforated cells of fluorescent dyes (calcein, carboxyfluorescein, Alexa Fluor 488 Phalloidin), which otherwise do not penetrate cell membranes, was dependent upon the dcEF strength and duration in any given single electrical field exposure. The method yields reproducible results, makes it easy to load large volumes of cell suspensions with membrane non-penetrating substances, and permits the elimination of irreversibly electroporated cells of diameter greater than desired. The results concur with and elaborate on those in earlier reports on cell electroporation in commercially available electroporators. They proved once more that the observed cell perforation does not depend upon the thermal effects of the electric current upon cells. In addition, the method eliminates many of the limitations of commercial electroporators and disposable electroporation chambers. It permits the optimization of conditions in which reversible and irreversible electroporation are separated. Over 90% of reversibly electroporated cells remain viable after one short (less than 400 ms) exposure to the localized dcEF. Experiments were conducted with the AT-2 cancer prostate cell line, human skin fibroblasts and human red blood cells, but they could be run with suspensions of any cell type. It is postulated that the described method could be useful for many purposes in biotechnology and biomedicine and could help optimize conditions for in vivo use of both reversible and irreversible electroporation.
Title: Reversible and irreversible electroporation of cell suspensions flowing through a localized DC electric field
Description:
AbstractExperiments on reversible and irreversible cell electroporation were carried out with an experimental setup based on a standard apparatus for horizontal electrophoresis, a syringe pump with regulated cell suspension flow velocity and a dcEF power supply.
Cells in suspension flowing through an orifice in a barrier inserted into the electrophoresis apparatus were exposed to defined localized dcEFs in the range of 0–1000 V/cm for a selected duration in the range 10–1000 ms.
This method permitted the determination of the viability of irreversibly electroperforated cells.
It also showed that the uptake by reversibly electroperforated cells of fluorescent dyes (calcein, carboxyfluorescein, Alexa Fluor 488 Phalloidin), which otherwise do not penetrate cell membranes, was dependent upon the dcEF strength and duration in any given single electrical field exposure.
The method yields reproducible results, makes it easy to load large volumes of cell suspensions with membrane non-penetrating substances, and permits the elimination of irreversibly electroporated cells of diameter greater than desired.
The results concur with and elaborate on those in earlier reports on cell electroporation in commercially available electroporators.
They proved once more that the observed cell perforation does not depend upon the thermal effects of the electric current upon cells.
In addition, the method eliminates many of the limitations of commercial electroporators and disposable electroporation chambers.
It permits the optimization of conditions in which reversible and irreversible electroporation are separated.
Over 90% of reversibly electroporated cells remain viable after one short (less than 400 ms) exposure to the localized dcEF.
Experiments were conducted with the AT-2 cancer prostate cell line, human skin fibroblasts and human red blood cells, but they could be run with suspensions of any cell type.
It is postulated that the described method could be useful for many purposes in biotechnology and biomedicine and could help optimize conditions for in vivo use of both reversible and irreversible electroporation.

Related Results

Abstract 819: Investigating the impacts of membrane potential on nano-electroporation efficacy
Abstract 819: Investigating the impacts of membrane potential on nano-electroporation efficacy
Abstract Electroporation has been shown to be an effective method of intracellular drug delivery and tissue ablation, however it faces significant challenges not onl...
An e-learning application on electrochemotherapy
An e-learning application on electrochemotherapy
Abstract Background Electrochemotherapy is an effective approach in local tumour treatment employing locally applied high-voltage electric pulses...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Optimizing the electroporation parameters forHeterometopus palaeformis (strain RAJCA) v1
Optimizing the electroporation parameters forHeterometopus palaeformis (strain RAJCA) v1
Cell viability after incubation with different electroporation buffers, Phosphate buffered saline (PBS) is used as an electroporation buffer for many eukaryotic cells. However, we...
Optimizing the electroporation parameters forHeterometopus palaeformis (strain RAJCA) v1
Optimizing the electroporation parameters forHeterometopus palaeformis (strain RAJCA) v1
Cell viability after incubation with different electroporation buffers, Phosphate buffered saline (PBS) is used as an electroporation buffer for many eukaryotic cells. However, we...
A REVIEW OF TUMOR ABLATION APPLICATORS AND THEIR ROLE IN IRREVERSIBLE ELECTROPORATION THERAPY
A REVIEW OF TUMOR ABLATION APPLICATORS AND THEIR ROLE IN IRREVERSIBLE ELECTROPORATION THERAPY
Abstract: Electroporation is a phenomenon involving the formation of pores in cell membranes under the influence of short high voltage electric pulses. Depending on the parameters ...
Field-emission current densities of carbon nanotube under the different electric fields
Field-emission current densities of carbon nanotube under the different electric fields
The field emission current variation law of carbon nanotube in a large electric field range (0-32 V m-1) is analyzed in depth by combining the density functional theory with metal ...

Back to Top