Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

High-Precision Automated Workflow for Urinary Untargeted Metabolomic Epidemiology

View through CrossRef
Urine is a non-invasive biofluid that is rich in polar metabolites and well-suited for metabolomic epidemiology. However, due to individual variability in health and hydration status, the physiological concentration of urine can differ >15-fold, which can pose major challenges in untargeted LC-MS metabolomics. Although numerous urine normalization methods have been implemented (e.g., creatinine, specific gravity – SG), most are manual and therefore not practical for population-based studies. To address this issue, we developed a method to measure SG in 96-well-plates using a refractive index detector (RID), which exhibited accuracy within 85-115% and <3.4% precision. Bland-Altman statistics showed a mean deviation of -0.0001 SG units (limits of agreement: -0.0014-0.0011) relative to a hand held refractometer. Using this RID-based SG normalization, we developed an automated LC MS workflow for untargeted urinary metabolomics in 96-well-plate format. The workflow uses positive and negative ionization HILIC chromatography and acquires mass spectra in data independent acquisition (DIA) mode at 3 collision energies. Five technical internal standards (tISs) were used to monitor data quality in each method, all of which demonstrated raw coefficients of variation (CVs) <10% in the quality controls (QCs) and <20% in the samples for a small cohort (n=87 samples, n=22 QCs). Application in a large cohort (n=842 urine samples, n=248 QCs), demonstrated CVQC<5% and CVsamples<16% for 4/5 tISs after signal drift correction by cubic spline regression. The workflow identified >540 urinary metabolites including endogenous and exogenous compounds. This platform is suitable for performing urinary untargeted metabolomic epidemiology and will be useful for applications in population-based molecular phenotyping.
Title: High-Precision Automated Workflow for Urinary Untargeted Metabolomic Epidemiology
Description:
Urine is a non-invasive biofluid that is rich in polar metabolites and well-suited for metabolomic epidemiology.
However, due to individual variability in health and hydration status, the physiological concentration of urine can differ >15-fold, which can pose major challenges in untargeted LC-MS metabolomics.
Although numerous urine normalization methods have been implemented (e.
g.
, creatinine, specific gravity – SG), most are manual and therefore not practical for population-based studies.
To address this issue, we developed a method to measure SG in 96-well-plates using a refractive index detector (RID), which exhibited accuracy within 85-115% and <3.
4% precision.
Bland-Altman statistics showed a mean deviation of -0.
0001 SG units (limits of agreement: -0.
0014-0.
0011) relative to a hand held refractometer.
Using this RID-based SG normalization, we developed an automated LC MS workflow for untargeted urinary metabolomics in 96-well-plate format.
The workflow uses positive and negative ionization HILIC chromatography and acquires mass spectra in data independent acquisition (DIA) mode at 3 collision energies.
Five technical internal standards (tISs) were used to monitor data quality in each method, all of which demonstrated raw coefficients of variation (CVs) <10% in the quality controls (QCs) and <20% in the samples for a small cohort (n=87 samples, n=22 QCs).
Application in a large cohort (n=842 urine samples, n=248 QCs), demonstrated CVQC<5% and CVsamples<16% for 4/5 tISs after signal drift correction by cubic spline regression.
The workflow identified >540 urinary metabolites including endogenous and exogenous compounds.
This platform is suitable for performing urinary untargeted metabolomic epidemiology and will be useful for applications in population-based molecular phenotyping.

Related Results

Metabolomic characterization of human glioblastomas and patient plasma: a pilot study
Metabolomic characterization of human glioblastomas and patient plasma: a pilot study
Background Glioblastoma (GBM) is a clinically challenging primary brain tumor with poor survival outcome despite surgical resection and intensive chemoradiation. The metabolic hete...
Metabolomic characterization of human glioblastomas and patient plasma: a pilot study
Metabolomic characterization of human glioblastomas and patient plasma: a pilot study
Background Glioblastoma (GBM) is a clinically challenging primary brain tumor with poor survival outcome despite surgical resection and intensive chemoradiation. The metabolic hete...
Does Immediate Removal of Urinary Catheter Prevent Urinary Morbidities Following Cesarean Section: A Prospective Randomized Study
Does Immediate Removal of Urinary Catheter Prevent Urinary Morbidities Following Cesarean Section: A Prospective Randomized Study
Objective: Urinary catheters are known cause of urinary morbidities. The longer the catheter is retained, the greater the risk for contamination and infection. An increasing body o...
Separation strategies for untargeted metabolomics
Separation strategies for untargeted metabolomics
AbstractMetabolomics has rapidly become a profiling technique of choice for biomarker elucidation and molecular diagnostics in addition to studies focused on understanding disease ...
Reproducible Untargeted Metabolomics Data Analysis Workflow for Exhaustive MS/MS Annotation
Reproducible Untargeted Metabolomics Data Analysis Workflow for Exhaustive MS/MS Annotation
Unknown features in untargeted metabolomics and non-targeted analysis (NTA) are identified using fragment ions from MS/MS spectra to predict the structures of the unknown compounds...

Back to Top