Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Exploring the feasibility of uni-directional ATES in high ambient groundwater flow aquifers

View through CrossRef
In the context where the member states of the European Union are asked to reach the goal of net zero emission of greenhouse gases before 2050, many cities all over Europe are adopting sustainable energy systems. One of the primary sources of CO2 emission are building heating and cooling systems. As aquifers are commonly present in many urban areas, ground coupled heat pumps are a renewable solution that many countries are adopting to replace fossil based heating and cooling techniques.Aquifer thermal energy storage (ATES) is attained by storing thermal energy in groundwater aquifers. Hence, a key aquifer characteristic for ATES is the natural groundwater flow velocity. For velocities less than 25 m/y, bi-directional ATES is usually possible. For groundwater flow velocities greater than 25 m/y, ATES is still possible, but requires multiple doublets with a specific well placement to be able to compensate for the groundwater flow via upstream injection and downstream extraction. Alternatively, “pump and dump” systems, which generate thermal plumes that affect the downstream groundwater temperature and are not desirable for other users, are adopted.A possible way to tackle the issue of aquifers with high ambient groundwater flow velocity is to combine the two solutions described above by applying a uni-directional pumping scheme allowing to compensate for the groundwater flow by constantly injecting in the upstream well and extracting from the downstream well. Spacing of the wells should be adjusted to the storage cycle length and natural groundwater flow velocity to ensure re-capture the energy injected within the aquifer in the previous season from the upstream well and transported to the down-gradient extraction well by the groundwater flow. This concept would also mitigate the downstream effect of a thermal plume. In this research the results of a sensitivity and feasibility analysis of this concept are presented. The results show that optimal inter-well distance not only depends on storage cycle length and groundwater flow velocity, but also on storage volume. Downstream thermal pollution can be avoided and recovery of the heat/cold stored can reach values between 50-60% depending on the conditions.
Title: Exploring the feasibility of uni-directional ATES in high ambient groundwater flow aquifers
Description:
In the context where the member states of the European Union are asked to reach the goal of net zero emission of greenhouse gases before 2050, many cities all over Europe are adopting sustainable energy systems.
One of the primary sources of CO2 emission are building heating and cooling systems.
As aquifers are commonly present in many urban areas, ground coupled heat pumps are a renewable solution that many countries are adopting to replace fossil based heating and cooling techniques.
Aquifer thermal energy storage (ATES) is attained by storing thermal energy in groundwater aquifers.
Hence, a key aquifer characteristic for ATES is the natural groundwater flow velocity.
For velocities less than 25 m/y, bi-directional ATES is usually possible.
For groundwater flow velocities greater than 25 m/y, ATES is still possible, but requires multiple doublets with a specific well placement to be able to compensate for the groundwater flow via upstream injection and downstream extraction.
Alternatively, “pump and dump” systems, which generate thermal plumes that affect the downstream groundwater temperature and are not desirable for other users, are adopted.
A possible way to tackle the issue of aquifers with high ambient groundwater flow velocity is to combine the two solutions described above by applying a uni-directional pumping scheme allowing to compensate for the groundwater flow by constantly injecting in the upstream well and extracting from the downstream well.
Spacing of the wells should be adjusted to the storage cycle length and natural groundwater flow velocity to ensure re-capture the energy injected within the aquifer in the previous season from the upstream well and transported to the down-gradient extraction well by the groundwater flow.
This concept would also mitigate the downstream effect of a thermal plume.
In this research the results of a sensitivity and feasibility analysis of this concept are presented.
The results show that optimal inter-well distance not only depends on storage cycle length and groundwater flow velocity, but also on storage volume.
Downstream thermal pollution can be avoided and recovery of the heat/cold stored can reach values between 50-60% depending on the conditions.

Related Results

Characterizing Groundwater Quality, Recharge and Distribution under Anthropogenic conditions
Characterizing Groundwater Quality, Recharge and Distribution under Anthropogenic conditions
Awareness concerning sustainable groundwater management is gaining traction and calls for adequate understanding of the complexities of natural and anthropogenic processes and how ...
Impacts of Groundwater Decline on Aquifer Thermal Energy Storage Suitability in Spain
Impacts of Groundwater Decline on Aquifer Thermal Energy Storage Suitability in Spain
Aquifer Thermal Energy Storage (ATES) systems are among the technologies needed to decarbonize the heating and cooling of buildings. This study assesses the suitability of ATES sys...
Long-term dynamics of pesticide metabolites in soil and aquifers
Long-term dynamics of pesticide metabolites in soil and aquifers
Groundwater is one of the most important resources for drinking water, and has to be protected from the input of persistent substances. Nevertheless, pesticides and especially thei...
Policies for Aquifer Thermal Energy Storage (ATES)
Policies for Aquifer Thermal Energy Storage (ATES)
Aquifer thermal energy storage (ATES) is a promising technology for sustainable and climate-friendly space heating and cooling. Compared to conventional heating and cooling techniq...
Groundwater Dynamics in the Vietnamese Mekong Delta: Trends, Memory Effects, and Response Times
Groundwater Dynamics in the Vietnamese Mekong Delta: Trends, Memory Effects, and Response Times
Understanding groundwater behavior is essential for water resources management in alluvial deltas. This study investigated the trends of groundwater levels (GWLs), the memory effec...
IMPACT OF CLIMATE CHANGE ON GROUNDWATER RECHARGE IN HO CHI MINH CITY AREA
IMPACT OF CLIMATE CHANGE ON GROUNDWATER RECHARGE IN HO CHI MINH CITY AREA
Groundwater is very important for the development of Ho Chi Minh City since it provides 32% of water supply, however, the groundwater level is decreasing dramatically in recent yea...
A comprehensive bioassessment of karst aquifer flow paths 
A comprehensive bioassessment of karst aquifer flow paths 
Current challenges in the assessment of groundwater characteristics in karst areas result from the difficulties to effectively identify episodes of high water discharge and flow pa...
Characteristics of groundwater circulation and evolution in Yanhe spring basin driven by coal mining
Characteristics of groundwater circulation and evolution in Yanhe spring basin driven by coal mining
Abstract The Yanhe spring basin located in the Jindong coal base is relatively short of water resources and the ecological environment is fragile. With the large-scale mini...

Back to Top