Javascript must be enabled to continue!
Evaluation of apically extruded debris following glide-path preparation with different file systems
View through CrossRef
The amount of apically extruded debris following glide-path preparation of mesial root of 120 freshly extracted human mandibular molar teeth using Senseus ProFinder files, PathFile, G-Files, Scout-RaCe files, HyFlex glidepath files and V glide-path two file system is of interest. The Eppendorf tubes were used as test equipment for collecting debris and the average weight of the debris was measured using an electronic micro-balancing system. It was observed that regardless of the file system utilized, debris was expelled from the apex. The G files resulted in a lower quantity of debris being extruded (0.070 ą 0.002 mg). In contrast, the V glide-path two file system exhibited the highest amount of debris extrusion (0.110 ą 0.004 mg) compared to all other file systems.
Biomedical Informatics
Title: Evaluation of apically extruded debris following glide-path preparation with different file systems
Description:
The amount of apically extruded debris following glide-path preparation of mesial root of 120 freshly extracted human mandibular molar teeth using Senseus ProFinder files, PathFile, G-Files, Scout-RaCe files, HyFlex glidepath files and V glide-path two file system is of interest.
The Eppendorf tubes were used as test equipment for collecting debris and the average weight of the debris was measured using an electronic micro-balancing system.
It was observed that regardless of the file system utilized, debris was expelled from the apex.
The G files resulted in a lower quantity of debris being extruded (0.
070 ą 0.
002 mg).
In contrast, the V glide-path two file system exhibited the highest amount of debris extrusion (0.
110 ą 0.
004 mg) compared to all other file systems.
Related Results
Comparative evaluation of the effect of glide path creation with Nitiflex hand K- file, Proglider and Path file on canal transportation and concentricity in apically curved canals - An In- Vitro study.
Comparative evaluation of the effect of glide path creation with Nitiflex hand K- file, Proglider and Path file on canal transportation and concentricity in apically curved canals - An In- Vitro study.
Abstract
Aim:
To compare and evaluate the effect of glide path creation with Nitiflex hand K- file, Proglider and Path file on canal transportation and concentricity in...
Quantitative evaluation of debris extruded apically using reciprocating versus continuous rotation single file with rotary and hand glide path file
Quantitative evaluation of debris extruded apically using reciprocating versus continuous rotation single file with rotary and hand glide path file
Chemomechanical root canal preparation (CMRCP) is an important step in root canal treatment. However, one of its negative consequences is apical extrusion of debris of the root can...
Quantitative evaluation of the apically extruded debris from root canals prepared by single-file rotary and reciprocating file systems: An in vitro study
Quantitative evaluation of the apically extruded debris from root canals prepared by single-file rotary and reciprocating file systems: An in vitro study
Aim:
The aim is to investigate and compare the amount of apically extruded debris after root canal preparation using single rotary and reciprocating file system...
Anthropogenic materials in the nests of Passerine birds: does the environment matter?
Anthropogenic materials in the nests of Passerine birds: does the environment matter?
Background. For several past decades, a notable pollution of the environment by different kinds of solid waste has been noted. The number of studies addressing the issue of utilisi...
Comparative Evaluation of Apically Extruded Debris with Hyflex Edm, MTWO and Self Adjusting File Systems; An In –Vitro Study
Comparative Evaluation of Apically Extruded Debris with Hyflex Edm, MTWO and Self Adjusting File Systems; An In –Vitro Study
Aim of the Study: To compare and evaluate the amount of apically extruded debris with Hyflex EDM, Mtwo, and the Self-Adjusting File systems.Materials and Methods: Sixty single-root...
An Ex-vivo Comparative Evaluation of Apical Debris And Irrigant Extrusion From Curved Canals Using Three Different Ni-Ti Instruments With Conventional Irrigation Methods.
An Ex-vivo Comparative Evaluation of Apical Debris And Irrigant Extrusion From Curved Canals Using Three Different Ni-Ti Instruments With Conventional Irrigation Methods.
An Ex-vivo Comparative Evaluation of Apical Debris And Irrigant Extrusion From Curved Canals Using Three Different Ni-Ti Instruments With Conventional Irrigation Methods.
...
Debris cover effect on the evolution of glaciation in the Northern Caucasus
Debris cover effect on the evolution of glaciation in the Northern Caucasus
<p>A common disadvantage of almost all global glacier models is that they ignore the explicit description of the debris cover on the heat exchange of the glacier surf...

