Quasi-Static Fracture Toughness and Damage Monitoring in Liquid Metal Reinforced Hybrid Composites
View through CrossRef
An experimental study is performed to investigate the quasi-static fracture toughness and damage monitoring capabilities of liquid metal (75.5% Gallium/24.5% Indium) reinforced intraply glass/carbon hybrid composites. Two different layups (G-0, where glass fibers are along the crack propagation direction; C-0, where carbon fibers are along the crack propagation direction) and two different weight percentages of liquid metal (1% and 2%) are considered in the fabrication of the composites. A novel four-probe technique is employed to determine the piezo-resistive damage response under mode-I fracture loading conditions. The effect of layups and liquid metal concentrations on fracture toughness and changes in piezo-resistance response is discussed. The C-composite without liquid metal demonstrated higher fracture toughness compared to that of the G-composite due to carbon fiber breakage. The addition of liquid metal decreases the fracture initiation toughness of both G- and C-composites. Scanning electron microscopy images show that liquid metal takes the form of large liquid metal pockets and small spherical droplets on the fracture surfaces. In both C- and G-composites, the peak resistance change of composites with 2% liquid metal is substantially lower than that of both no-liquid metal and 1% liquid metal composites.
Title: Quasi-Static Fracture Toughness and Damage Monitoring in Liquid Metal Reinforced Hybrid Composites
Description:
An experimental study is performed to investigate the quasi-static fracture toughness and damage monitoring capabilities of liquid metal (75.
5% Gallium/24.
5% Indium) reinforced intraply glass/carbon hybrid composites.
Two different layups (G-0, where glass fibers are along the crack propagation direction; C-0, where carbon fibers are along the crack propagation direction) and two different weight percentages of liquid metal (1% and 2%) are considered in the fabrication of the composites.
A novel four-probe technique is employed to determine the piezo-resistive damage response under mode-I fracture loading conditions.
The effect of layups and liquid metal concentrations on fracture toughness and changes in piezo-resistance response is discussed.
The C-composite without liquid metal demonstrated higher fracture toughness compared to that of the G-composite due to carbon fiber breakage.
The addition of liquid metal decreases the fracture initiation toughness of both G- and C-composites.
Scanning electron microscopy images show that liquid metal takes the form of large liquid metal pockets and small spherical droplets on the fracture surfaces.
In both C- and G-composites, the peak resistance change of composites with 2% liquid metal is substantially lower than that of both no-liquid metal and 1% liquid metal composites.
Related Results
Mechanical response and damage monitoring in hybrid composites under extreme loading conditions
Mechanical response and damage monitoring in hybrid composites under extreme loading conditions
The rising interest in composite materials within aerospace, defense, and automotive industries has prompted a thorough investigation of their material behavior and development of ...
Pragmatic Trends for Estimating Constraint Effects on Upper-Shelf Fracture Toughness for Pipe Flaw Evaluation
Pragmatic Trends for Estimating Constraint Effects on Upper-Shelf Fracture Toughness for Pipe Flaw Evaluation
Abstract
During efforts for a PRCI project to assess the toughness for critical flaw size evaluations of vintage axially surface-cracked line-pipe steels for the DOT...
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Abstract
In this paper, a case study in a fractured carbonate reservoir is presented to demonstrate the approach of fracture modeling using fracture intensity vol...
Linkage of Fracture Assessment Methodology With Fracture Toughness Testing Procedures
Linkage of Fracture Assessment Methodology With Fracture Toughness Testing Procedures
Abstract
J-Integral, J, is a commonly accepted elastic-plastic fracture mechanics parameter defined as the amount of energy released per unit area of crack surface i...
Influence of Material Composition on Mechanical Properties and Fracture Behavior of Ceramic-Metal Composites
Influence of Material Composition on Mechanical Properties and Fracture Behavior of Ceramic-Metal Composites
In order to estimate distribution of mechanical properties and fracture toughness in
ceramic-metal functionally graded materials (FGMs), mechanical properties and fracture behavior...
Mechanical Properties of GF/CF Hybrid ABS Composite by DFFIM
Mechanical Properties of GF/CF Hybrid ABS Composite by DFFIM
GF reinforced polymer composites to improve the mechanical properties by increasing fiber content, but there is a limit. On the contrary, CF reinforced polymer composites are super...
Quantifying the Sensitivity of Dielectric Dispersion Data to Fracture Properties in Fractured Rocks
Quantifying the Sensitivity of Dielectric Dispersion Data to Fracture Properties in Fractured Rocks
Evaluation of fluid storage and flow capacity of a fractured rock system needs a comprehensive characterization of all the fracture properties. These properties include the fractur...
Fracture Toughness Characterization of 304L and 316L Austenitic Stainless Steels and Alloy 718 After Irradiation in High-Energy, Mixed Proton/Neutron Spectrum
Fracture Toughness Characterization of 304L and 316L Austenitic Stainless Steels and Alloy 718 After Irradiation in High-Energy, Mixed Proton/Neutron Spectrum
This paper describes the fracture toughness characterization of annealed 304L and 316L stainless steels and precipitation hardened Alloy 718, performed at the Oak Ridge National La...