Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of pupil size measurement: Repeatability and agreement across four devices with different measurement principles under varied lighting conditions

View through CrossRef
Abstract Aim To evaluate the repeatability of pupil size measurements obtained with four different devices under varying lighting conditions and to assess the agreement between them. Methods This prospective study included 80 healthy participants with a mean age of 27.5 ± 8.8 years (range 19–58). Pupil size was measured under mesopic (4 lux) and low photopic (50 lux) conditions using two open‐field devices (tabletop and handheld PowerRefractors) and two closed‐field devices (MS‐39 and NIDEK Tonoref III). Three consecutive measurements were taken per eye for each device. Repeatability was analysed using the repeatability limit (R Limit), while the agreement was assessed with Bland–Altman analysis. Results All devices demonstrated R Limits lower than 1 mm under both low photopic and mesopic conditions. The NIDEK Tonoref III had the best repeatability under low photopic conditions (R Limit = 0.52 mm), while the tabletop PowerRefractor had the best R Limit under mesopic conditions (0.68 mm). The agreement analysis under mesopic conditions revealed smaller mean differences and narrower limits of agreement (LoA) (approximately 2 mm) among devices with similar designs (tabletop with handheld PowerRefractor and MS‐39 with NIDEK Tonoref III), while combinations of designs exhibited wider variability. Mesopic conditions yielded more consistent LoA across all device pairs. Conclusions All devices showed excellent repeatability. Instruments with similar measurement designs demonstrated better agreement, particularly under low photopic conditions. Significant variability existed when comparing open‐ and closed‐field devices. These findings underscore the importance of selecting appropriate instruments for clinical and research applications, and highlight the need for further validation of pupillometry devices.
Title: Comparison of pupil size measurement: Repeatability and agreement across four devices with different measurement principles under varied lighting conditions
Description:
Abstract Aim To evaluate the repeatability of pupil size measurements obtained with four different devices under varying lighting conditions and to assess the agreement between them.
Methods This prospective study included 80 healthy participants with a mean age of 27.
5 ± 8.
8 years (range 19–58).
Pupil size was measured under mesopic (4 lux) and low photopic (50 lux) conditions using two open‐field devices (tabletop and handheld PowerRefractors) and two closed‐field devices (MS‐39 and NIDEK Tonoref III).
Three consecutive measurements were taken per eye for each device.
Repeatability was analysed using the repeatability limit (R Limit), while the agreement was assessed with Bland–Altman analysis.
Results All devices demonstrated R Limits lower than 1 mm under both low photopic and mesopic conditions.
The NIDEK Tonoref III had the best repeatability under low photopic conditions (R Limit = 0.
52 mm), while the tabletop PowerRefractor had the best R Limit under mesopic conditions (0.
68 mm).
The agreement analysis under mesopic conditions revealed smaller mean differences and narrower limits of agreement (LoA) (approximately 2 mm) among devices with similar designs (tabletop with handheld PowerRefractor and MS‐39 with NIDEK Tonoref III), while combinations of designs exhibited wider variability.
Mesopic conditions yielded more consistent LoA across all device pairs.
Conclusions All devices showed excellent repeatability.
Instruments with similar measurement designs demonstrated better agreement, particularly under low photopic conditions.
Significant variability existed when comparing open‐ and closed‐field devices.
These findings underscore the importance of selecting appropriate instruments for clinical and research applications, and highlight the need for further validation of pupillometry devices.

Related Results

Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Abstract Introduction The exact manner in which large language models (LLMs) will be integrated into pathology is not yet fully comprehended. This study examines the accuracy, bene...
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
<p><em><span style="font-size: 11.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-langua...
Examining pupil characteristics and relative afferent pupil defect prevalence in Syrian patients
Examining pupil characteristics and relative afferent pupil defect prevalence in Syrian patients
Purpose: This study aims to explore pupil characteristics in a cohort of Syrian patients across different age groups and under varying luminance conditions, bot...
A COMPREHENSIVE REVIEW OF ENERGY-EFFICIENT LIGHTING TECHNOLOGIES AND TRENDS
A COMPREHENSIVE REVIEW OF ENERGY-EFFICIENT LIGHTING TECHNOLOGIES AND TRENDS
Energy-efficient lighting technologies have undergone significant advancements in recent years, driving a transformation in the lighting industry. This comprehensive review explore...
Simple Nomographs for Assessing Lighting in Urban Environments
Simple Nomographs for Assessing Lighting in Urban Environments
<p>Incorporating different technologies and lighting techniques in the illumination of structures has allowed us to portray fantastic night time vistas of our cities. However...
Pupil-associated states modulate excitability but not stimulus selectivity in primary auditory cortex
Pupil-associated states modulate excitability but not stimulus selectivity in primary auditory cortex
Abstract Recent research in mice indicates that luminance-independent fluctuations in pupil size predict variability in spontaneous and evoked activity of single ne...
Pupil diameter tracked during motor adaptation in humans
Pupil diameter tracked during motor adaptation in humans
Abstract Pupil diameter, under constant illumination, is known to reflect individuals’ internal states, such as surprise about observation and environmental uncerta...

Back to Top