Exploring Temporal Dynamics in No-Reflow Assessment

View through CrossRef
Abstract Background For acute ischemic stroke (AIS) patients, successful endovascular thrombectomy (EVT) may not recover functional independence. One potential mechanism driving this disparity is no-reflow, a lack of perfusion despite recanalization of the large vessel occlusion (LVO). None of the published methods for assessing no-reflow have gained acceptance, and debate persists about isolating no-reflow from upstream hemodynamic anomalies as well as the temporal dynamics no-reflow assessment. This work conducts an exploratory analysis of the effect of time since EVT on the performance of different methods for assessing no-reflow. Methods We identified a cohort of UCLA Health patients with successful LVO recanalization (≥ mTICI 2b) of a thrombus located in M1 or ICA. Patients were stratified into ‘early’ and ‘follow-up’ cohorts of < 24 and < 48 hours since EVT. A set of published methods using perfusion imaging for no-reflow detection were adapted to run semi-automatically for both cohorts. Results We compiled 83 imaging studies from 64 patients. No-reflow rates varied from 4 . 2 % to 51 . 4 % by method, time since EVT, and mTICI. Follow-up no-reflow rates more closely match the original literature across all methods. mTICI 2b patients likely inflated no-reflow, as rates dropped approximately 50 % for mTICI 2c/3 cases. Early cohort inter-method agreement shows kappa scores as low as − 0 . 017 , but improved up to 0 . 72 in the follow-up cohort. Conclusion No-reflow exhibits substantial dependence on time across all no-reflow detection methods studied. Inter-method agreement is good for methods using the same perfusion parameters, but each method is subject to confounding influences, motivating an aggregate method for robust evaluation. The temporal dynamics of no-reflow detection raises questions about imaging timing post-EVT for detection within the intervention window.
Title: Exploring Temporal Dynamics in No-Reflow Assessment
Description:
Abstract Background For acute ischemic stroke (AIS) patients, successful endovascular thrombectomy (EVT) may not recover functional independence.
One potential mechanism driving this disparity is no-reflow, a lack of perfusion despite recanalization of the large vessel occlusion (LVO).
None of the published methods for assessing no-reflow have gained acceptance, and debate persists about isolating no-reflow from upstream hemodynamic anomalies as well as the temporal dynamics no-reflow assessment.
This work conducts an exploratory analysis of the effect of time since EVT on the performance of different methods for assessing no-reflow.
Methods We identified a cohort of UCLA Health patients with successful LVO recanalization (≥ mTICI 2b) of a thrombus located in M1 or ICA.
Patients were stratified into ‘early’ and ‘follow-up’ cohorts of < 24 and < 48 hours since EVT.
A set of published methods using perfusion imaging for no-reflow detection were adapted to run semi-automatically for both cohorts.
Results We compiled 83 imaging studies from 64 patients.
No-reflow rates varied from 4 .
2 % to 51 .
4 % by method, time since EVT, and mTICI.
Follow-up no-reflow rates more closely match the original literature across all methods.
mTICI 2b patients likely inflated no-reflow, as rates dropped approximately 50 % for mTICI 2c/3 cases.
Early cohort inter-method agreement shows kappa scores as low as − 0 .
017 , but improved up to 0 .
72 in the follow-up cohort.
Conclusion No-reflow exhibits substantial dependence on time across all no-reflow detection methods studied.
Inter-method agreement is good for methods using the same perfusion parameters, but each method is subject to confounding influences, motivating an aggregate method for robust evaluation.
The temporal dynamics of no-reflow detection raises questions about imaging timing post-EVT for detection within the intervention window.

Related Results

Solder Reflow Method and Reflow Temperature Profile
Solder Reflow Method and Reflow Temperature Profile
ABSTRACT The major cause of integrated circuit package failure mechanisms such as delamination, internal cracking or popcorning is package saturation with moistur...
Outcomes of PIANO Score for No-Reflow in Patients Undergoing Primary Percutaneous Coronary Intervention: A Retrospective Study
Outcomes of PIANO Score for No-Reflow in Patients Undergoing Primary Percutaneous Coronary Intervention: A Retrospective Study
BACKGROUND: The no-reflow phenomenon, characterized by inadequate myocardial reperfusion despite successful epicardial vessel revascularization, remains a significant challenge in ...
Prevalence and Association of No-Reflow with The Total Ischemic Time in Patients Undergoing Primary Angioplasty
Prevalence and Association of No-Reflow with The Total Ischemic Time in Patients Undergoing Primary Angioplasty
The no-reflow phenomenon is harmful; hence, early diagnosis of its prevalence and predictors is crucial. Few said the time between the first symptom and PCI was a risk factor. Afte...
Thermal profiling: a reflow process based on the heating factor
Thermal profiling: a reflow process based on the heating factor
PurposeThis paper aims to offer a convenient method to develop an oven recipe for a specific soldering profile in a reflow process. The method is devised to quickly achieve proper ...
Wetting Kinetics and Joint Strength of Sn-0.3Ag-0.7Cu Lead-Free Solder Alloy on Copper Substrate as a Function of Reflow Time
Wetting Kinetics and Joint Strength of Sn-0.3Ag-0.7Cu Lead-Free Solder Alloy on Copper Substrate as a Function of Reflow Time
Solder plays a vital role in the interconnection of electronic devices in electronic assemblies. As an interconnection material, the solder joint executes electrical, mechanical an...
Role of the Frontal Lobes in the Propagation of Mesial Temporal Lobe Seizures
Role of the Frontal Lobes in the Propagation of Mesial Temporal Lobe Seizures
Summary: The depth ictal electroencephalographic (EEG) propagation sequence accompanying 78 complex partial seizures of mesial temporal origin was reviewed in 24 patients (15 from...

Back to Top