Javascript must be enabled to continue!
Analyzing the accuracy of a cross‐mounting technique utilizing digitized interocclusal records
View through CrossRef
Abstract
Purpose
To compare the accuracy of a partially digital cross‐mounting workflow of direct scans of interocclusal records to a conventional workflow by analyzing the deviations of sequentially cross‐mounted casts.
Materials and methods
A set of reference casts, comprising maxillary and mandibular full‐arch prepared casts and interim prostheses, was articulated, mounted, and scanned to generate four reference casts for cross‐mounting. In the conventional approach, 15 sets of these four casts were printed. Polyvinylsiloxane (PVS) records were made using the reference casts and utilized for sequential cross‐mounting. In the partially digital group, the same PVS interocclusal records were scanned and used for digital cross‐mounting via design software. The mean deviations of both groups from the reference cast were analyzed using a 3D inspection software program. Statistical tests, including paired
t
‐test and analysis of variance (ANOVA), were conducted to compare the average discrepancies between the two groups and to evaluate discrepancies in the anterior and posterior regions (α
=
0.05).
Results
The range of discrepancies was similar in both the conventional and partially digital groups. The final set of related casts had a mean deviation of 201.58 ± 136.98 mm in the conventional workflow and 248.69 ± 164.71 mm in the partially digital workflow. No statistically significant difference was found between conventional and partially digital groups (
p =
0.091). Error propagation was examined by comparing discrepancies at each step within the cross‐mounting process. In the conventional group, no significant difference was found (
p =
0.148), but a significant difference was found among groups in the partially digital group at each step of sequential mounting (
p <
0.001). A significant difference was observed between anterior and posterior deviations in the partially digital group (
p <
0.001), but not in the conventional group (
p =
0.143).
Conclusions
The study reveals that there is no statistically significant difference between conventional and partially digital cross‐mounting workflows. However, within the partially digital group, a significant difference in deviation emerges across cross‐mounting steps, with increased deviation in the anterior region.
Title: Analyzing the accuracy of a cross‐mounting technique utilizing digitized interocclusal records
Description:
Abstract
Purpose
To compare the accuracy of a partially digital cross‐mounting workflow of direct scans of interocclusal records to a conventional workflow by analyzing the deviations of sequentially cross‐mounted casts.
Materials and methods
A set of reference casts, comprising maxillary and mandibular full‐arch prepared casts and interim prostheses, was articulated, mounted, and scanned to generate four reference casts for cross‐mounting.
In the conventional approach, 15 sets of these four casts were printed.
Polyvinylsiloxane (PVS) records were made using the reference casts and utilized for sequential cross‐mounting.
In the partially digital group, the same PVS interocclusal records were scanned and used for digital cross‐mounting via design software.
The mean deviations of both groups from the reference cast were analyzed using a 3D inspection software program.
Statistical tests, including paired
t
‐test and analysis of variance (ANOVA), were conducted to compare the average discrepancies between the two groups and to evaluate discrepancies in the anterior and posterior regions (α
=
0.
05).
Results
The range of discrepancies was similar in both the conventional and partially digital groups.
The final set of related casts had a mean deviation of 201.
58 ± 136.
98 mm in the conventional workflow and 248.
69 ± 164.
71 mm in the partially digital workflow.
No statistically significant difference was found between conventional and partially digital groups (
p =
0.
091).
Error propagation was examined by comparing discrepancies at each step within the cross‐mounting process.
In the conventional group, no significant difference was found (
p =
0.
148), but a significant difference was found among groups in the partially digital group at each step of sequential mounting (
p <
0.
001).
A significant difference was observed between anterior and posterior deviations in the partially digital group (
p <
0.
001), but not in the conventional group (
p =
0.
143).
Conclusions
The study reveals that there is no statistically significant difference between conventional and partially digital cross‐mounting workflows.
However, within the partially digital group, a significant difference in deviation emerges across cross‐mounting steps, with increased deviation in the anterior region.
Related Results
Engine Mounting Systems for Electric Powertrains: Mounting Layouts and Design Parameters
Engine Mounting Systems for Electric Powertrains: Mounting Layouts and Design Parameters
Abstract
The vibroacoustic characteristics of electric powertrains are well known to significantly differ from internal combustion engines. A relatively very high po...
Mounting Systems for Electric Powertrains: Optimization and Parameter Sensitivity
Mounting Systems for Electric Powertrains: Optimization and Parameter Sensitivity
Abstract
Noise, vibration, and harshness (NVH) characteristics of electric powertrains have been receiving increasing attention due to the unique vibroacoustic chara...
AN ASSESSMENT OF E-RECORDS READINESS AT THE MINISTRY OF LABOUR AND HOME AFFAIRS, GABORONE, BOTSWANA
AN ASSESSMENT OF E-RECORDS READINESS AT THE MINISTRY OF LABOUR AND HOME AFFAIRS, GABORONE, BOTSWANA
This study sought to assess electronic records (e-records) readiness at the Ministry of Labour and Home Affairs (MLHA), Gaborone, Botswana, within the purview of the implementation...
Comparative Evaluation Of Clinical And Radiographic Horizontal Condylar Guidance Angle Values By Using Two Different Interocclusal Recording Materials In Dentulous Patients
Comparative Evaluation Of Clinical And Radiographic Horizontal Condylar Guidance Angle Values By Using Two Different Interocclusal Recording Materials In Dentulous Patients
Introduction: The success of prosthodontic procedures can be accurately determined by the exact replication of the patient’s condylar path using a semi-adjustable articulator. It a...
Optimization of the Wing Parameters for a Winged Subsoiler
Optimization of the Wing Parameters for a Winged Subsoiler
ABSTRACT. The wing parameters of a subsoiler, such as the location and angle of the wings, have an important impact on the operating performance of the winged subsoilers. To study ...
Exploring Strategies for Optimizing Mobilenetv2 Performance in Classification Tasks Through Transfer Learning and Hyperparameter Tuning with A Local Dataset from Kigezi, Uganda.
Exploring Strategies for Optimizing Mobilenetv2 Performance in Classification Tasks Through Transfer Learning and Hyperparameter Tuning with A Local Dataset from Kigezi, Uganda.
Abstract
Background
Deep learning has proved to very vital in numerous applications in recent years. However, the development of a model may require access to datasets. Trainin...
Comparative evaluation of dimensional stability, accuracy, and reproducibility of two commercially available interocclusal recording materials: An in vitro study
Comparative evaluation of dimensional stability, accuracy, and reproducibility of two commercially available interocclusal recording materials: An in vitro study
Abstract
Aim:
The study aimed to evaluate and compare the dimensional stability, accuracy, and reproducibility of two com...
Italian Bird Rarities Committee (COI) - Report 29
Italian Bird Rarities Committee (COI) - Report 29
Italian Birds Rarities Committee (COI) - Report 29. This report refers to records from January 1st to December 31st 2019, with the addition of a number of records from previous yea...

