Javascript must be enabled to continue!
Analyzing the accuracy of a cross‐mounting technique utilizing digitized interocclusal records
View through CrossRef
Abstract
Purpose
To compare the accuracy of a partially digital cross‐mounting workflow of direct scans of interocclusal records to a conventional workflow by analyzing the deviations of sequentially cross‐mounted casts.
Materials and methods
A set of reference casts, comprising maxillary and mandibular full‐arch prepared casts and interim prostheses, was articulated, mounted, and scanned to generate four reference casts for cross‐mounting. In the conventional approach, 15 sets of these four casts were printed. Polyvinylsiloxane (PVS) records were made using the reference casts and utilized for sequential cross‐mounting. In the partially digital group, the same PVS interocclusal records were scanned and used for digital cross‐mounting via design software. The mean deviations of both groups from the reference cast were analyzed using a 3D inspection software program. Statistical tests, including paired
t
‐test and analysis of variance (ANOVA), were conducted to compare the average discrepancies between the two groups and to evaluate discrepancies in the anterior and posterior regions (α
=
0.05).
Results
The range of discrepancies was similar in both the conventional and partially digital groups. The final set of related casts had a mean deviation of 201.58 ± 136.98 mm in the conventional workflow and 248.69 ± 164.71 mm in the partially digital workflow. No statistically significant difference was found between conventional and partially digital groups (
p =
0.091). Error propagation was examined by comparing discrepancies at each step within the cross‐mounting process. In the conventional group, no significant difference was found (
p =
0.148), but a significant difference was found among groups in the partially digital group at each step of sequential mounting (
p <
0.001). A significant difference was observed between anterior and posterior deviations in the partially digital group (
p <
0.001), but not in the conventional group (
p =
0.143).
Conclusions
The study reveals that there is no statistically significant difference between conventional and partially digital cross‐mounting workflows. However, within the partially digital group, a significant difference in deviation emerges across cross‐mounting steps, with increased deviation in the anterior region.
Title: Analyzing the accuracy of a cross‐mounting technique utilizing digitized interocclusal records
Description:
Abstract
Purpose
To compare the accuracy of a partially digital cross‐mounting workflow of direct scans of interocclusal records to a conventional workflow by analyzing the deviations of sequentially cross‐mounted casts.
Materials and methods
A set of reference casts, comprising maxillary and mandibular full‐arch prepared casts and interim prostheses, was articulated, mounted, and scanned to generate four reference casts for cross‐mounting.
In the conventional approach, 15 sets of these four casts were printed.
Polyvinylsiloxane (PVS) records were made using the reference casts and utilized for sequential cross‐mounting.
In the partially digital group, the same PVS interocclusal records were scanned and used for digital cross‐mounting via design software.
The mean deviations of both groups from the reference cast were analyzed using a 3D inspection software program.
Statistical tests, including paired
t
‐test and analysis of variance (ANOVA), were conducted to compare the average discrepancies between the two groups and to evaluate discrepancies in the anterior and posterior regions (α
=
0.
05).
Results
The range of discrepancies was similar in both the conventional and partially digital groups.
The final set of related casts had a mean deviation of 201.
58 ± 136.
98 mm in the conventional workflow and 248.
69 ± 164.
71 mm in the partially digital workflow.
No statistically significant difference was found between conventional and partially digital groups (
p =
0.
091).
Error propagation was examined by comparing discrepancies at each step within the cross‐mounting process.
In the conventional group, no significant difference was found (
p =
0.
148), but a significant difference was found among groups in the partially digital group at each step of sequential mounting (
p <
0.
001).
A significant difference was observed between anterior and posterior deviations in the partially digital group (
p <
0.
001), but not in the conventional group (
p =
0.
143).
Conclusions
The study reveals that there is no statistically significant difference between conventional and partially digital cross‐mounting workflows.
However, within the partially digital group, a significant difference in deviation emerges across cross‐mounting steps, with increased deviation in the anterior region.
Related Results
Engine Mounting Systems for Electric Powertrains: Mounting Layouts and Design Parameters
Engine Mounting Systems for Electric Powertrains: Mounting Layouts and Design Parameters
Abstract
The vibroacoustic characteristics of electric powertrains are well known to significantly differ from internal combustion engines. A relatively very high po...
Comparative Evaluation Of Clinical And Radiographic Horizontal Condylar Guidance Angle Values By Using Two Different Interocclusal Recording Materials In Dentulous Patients
Comparative Evaluation Of Clinical And Radiographic Horizontal Condylar Guidance Angle Values By Using Two Different Interocclusal Recording Materials In Dentulous Patients
Introduction: The success of prosthodontic procedures can be accurately determined by the exact replication of the patient’s condylar path using a semi-adjustable articulator. It a...
Italian Bird Rarities Committee (COI) - Report 29
Italian Bird Rarities Committee (COI) - Report 29
Italian Birds Rarities Committee (COI) - Report 29. This report refers to records from January 1st to December 31st 2019, with the addition of a number of records from previous yea...
Short-term effects of a Rigid Interocclusal Appliance and Hypnosis on individuals with bruxism: a feasibility study for a randomized clinical trial
Short-term effects of a Rigid Interocclusal Appliance and Hypnosis on individuals with bruxism: a feasibility study for a randomized clinical trial
This study had the aim of evaluate the feasibility of a randomized clinical trial to compare the effects of a Rigid Interocclusal Appliance and Hypnosis on the quality of life and ...
Digital Analysis of Closest Speaking Space in Dentates—Method Proposal and Preliminary Findings
Digital Analysis of Closest Speaking Space in Dentates—Method Proposal and Preliminary Findings
Aims: The aim of this study is to identify methods for the digital analysis of the closest speaking space in dentates and to assess certain particularities using digital analysis. ...
ISSN i registracija digitalizovanih serijskih publikacija = ISSN and Registration of the Digitized Serial Publications
ISSN i registracija digitalizovanih serijskih publikacija = ISSN and Registration of the Digitized Serial Publications
Šta se dešava nakon digitalizacije građe, obrade digitalizovanog materijala, tačnije ocerovanja2? Kako se digi-talizovana serijska publikacija katalogizuje? Da li joj se dodjeljuje...
The Science of Engine Mounts and its Multidimensional Impact on Noise and Vibrations in Passenger Car
The Science of Engine Mounts and its Multidimensional Impact on Noise and Vibrations in Passenger Car
<div class="section abstract"><div class="htmlview paragraph">A robust process of specifying engine mounting systems for internal combustion engines (ICE) has been esta...
Commissione Ornitologica Italiana (COI) - Report 28
Commissione Ornitologica Italiana (COI) - Report 28
Italian Ornithological Commission (COI) - Report 28. This report refers to records from 2018, with the addition of a number of records from previous years which were submitted more...

