Javascript must be enabled to continue!
Design-Based Thermal Efficiency Correction Method for Hot Water Boiler
View through CrossRef
Abstract
In the boiler design process, the thermal efficiency of the boiler operating under specified parameters is given in accordance with the design specifications. However, under the actual operating conditions, the specified parameters in the design book cannot be met at the same time. Especially for the hot water boiler, the coal quality component and the deviation of low calorific power, the feed water temperature and the ambient temperature will directly affect the operating efficiency of the boiler. In the current boiler energy efficiency test standards, the test conditions are very demanding. It is required to be the design coal type and it also gives fluctuation ranges for several parameters that affect the boiler operation efficiency. For non-design conditions, the boiler operation condition test method can only be executed referring to the standard. However, the measured efficiency is highly variable. This paper aims to analyze and study several parameters affecting boiler efficiency based on the perspective of boiler design, and give corresponding efficiency correction method to provide reference for the correction of energy efficiency test results under non-design conditions.
Title: Design-Based Thermal Efficiency Correction Method for Hot Water Boiler
Description:
Abstract
In the boiler design process, the thermal efficiency of the boiler operating under specified parameters is given in accordance with the design specifications.
However, under the actual operating conditions, the specified parameters in the design book cannot be met at the same time.
Especially for the hot water boiler, the coal quality component and the deviation of low calorific power, the feed water temperature and the ambient temperature will directly affect the operating efficiency of the boiler.
In the current boiler energy efficiency test standards, the test conditions are very demanding.
It is required to be the design coal type and it also gives fluctuation ranges for several parameters that affect the boiler operation efficiency.
For non-design conditions, the boiler operation condition test method can only be executed referring to the standard.
However, the measured efficiency is highly variable.
This paper aims to analyze and study several parameters affecting boiler efficiency based on the perspective of boiler design, and give corresponding efficiency correction method to provide reference for the correction of energy efficiency test results under non-design conditions.
Related Results
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Abstract Purpose: The invention relates to the oil industry, inorganic chemistry, in particular, to the methods of complex processing of formation water, using flare gas of oil and...
Risk management framework and practices for boiler operations in Malaysia
Risk management framework and practices for boiler operations in Malaysia
Boiler operations had a reputation for being one of the most hazardous work environments. Workers in the boiler plant face many safety risks due to the nature of the job. The work ...
Near-Surface Properties of Europa Constrained by the Galileo PPR Measurements
Near-Surface Properties of Europa Constrained by the Galileo PPR Measurements
NASA's Europa Clipper mission will characterize the current and recent surface activity of the icy-moon Europa through a wide range of remote sensing observations. In particular, t...
Application of Rotating Magnet Ranging System and An Innovative Concept of Heat Recycling in SAGD Operation
Application of Rotating Magnet Ranging System and An Innovative Concept of Heat Recycling in SAGD Operation
Abstract
As a kind of methodology to develop coalbed methane in China, RMRS (Rotating Magnet Ranging System) has been popular in SAGD operation in recent years. In L...
Design and Development of the Novel Electrothermal Wall-Hanging Boiler
Design and Development of the Novel Electrothermal Wall-Hanging Boiler
Background:
With the rapid development of the domestic, independent heating system,
the wall-hanging boiler has become the focus of concern for a large number of users. As an indep...
PERSAMAAN REGRESI LINIER BERGANDA UNTUK MEMPREDIKSI EFISIENSI BOILER
PERSAMAAN REGRESI LINIER BERGANDA UNTUK MEMPREDIKSI EFISIENSI BOILER
Boiler efficiency calculation is crucial to determine the reliability of boiler performance. Generally, boiler efficiency is calculated by the heat loss method, which considers los...
Sustainable Reuse of Produced Water Treatment Waste in Drilling Operations
Sustainable Reuse of Produced Water Treatment Waste in Drilling Operations
Abstract
In oil and gas explorations, produced water is generated from subsurface reservoirs along with crude oil and gas. The produced water gets separated from hyd...

