Javascript must be enabled to continue!
Saya Comparative Analysis of Bovine Serum Albumin Detection Using Cuvettes, 1 Biofunctionalized, and Non-Biofunctionalized Tapered Optical Fiber
View through CrossRef
Advances in optical sensor technologies have been substantial in recent years, especially in the detection of biomolecules like Bovine 24 Serum Albumin (BSA), driven by the need for more sensitive and precise diagnostic tools. The detection of BSA plays a critical role, 25 particularly in the early diagnostic tools for chronic kidney disease. This work aims to investigate the performance of three different BSA 26 detection methods: biofunctionalized and non-biofunctionalized tapered optical fiber sensors and conventional cuvettes. This study 27 conducted an experimental investigation, utilizing a 3.5 ml cuvette and tapered optical fibers with design parameters including upper 28 and lower taper lengths of 10 mm, a waist length of 10 mm, and a waist diameter of 10 μm. The sensors were fabricated using the Vytran 29 GPX 3400 machine. Measurements of time response, intensity, and absorbance were carried out using a Deuterium-Tungsten DT-2-GS 30 light source and an Ocean Optics Flame spectrometer. The biofunctionalization of the sensing area involved three sequential steps: 31 hydroxylation with a 0.1M sodium hydroxide solution, salinization with a 2% (3-aminopropyl) triethoxysilane solution, and aldehyde 32 activation using a 2% glutaraldehyde solution. The experiment used 120 ml of BSA solutions at concentrations of 31.25 mg/dL, 62.5 33 mg/dL, and 125 mg/dL. Each method exhibits a unique spectral response across the ultraviolet, visible, and near-infrared regions. Both 34 intensity and absorbance assessments reveal a significant reduction in sensitivity when transitioning from the cuvette to the tapered 35 optical fiber. Notably, the sensitivity decreases by 99.96% for intensity measurements and by 97.76% for absorbance. Nonetheless, after 36 biofunctionalization, the tapered optical fiber's sensitivity increased, showing a 207.1% increase in absorbance and a 1494.72% increase 37 in intensity measurements compared to the non-biofunctionalized tapered optical fiber.
Title: Saya Comparative Analysis of Bovine Serum Albumin Detection Using Cuvettes, 1 Biofunctionalized, and Non-Biofunctionalized Tapered Optical Fiber
Description:
Advances in optical sensor technologies have been substantial in recent years, especially in the detection of biomolecules like Bovine 24 Serum Albumin (BSA), driven by the need for more sensitive and precise diagnostic tools.
The detection of BSA plays a critical role, 25 particularly in the early diagnostic tools for chronic kidney disease.
This work aims to investigate the performance of three different BSA 26 detection methods: biofunctionalized and non-biofunctionalized tapered optical fiber sensors and conventional cuvettes.
This study 27 conducted an experimental investigation, utilizing a 3.
5 ml cuvette and tapered optical fibers with design parameters including upper 28 and lower taper lengths of 10 mm, a waist length of 10 mm, and a waist diameter of 10 μm.
The sensors were fabricated using the Vytran 29 GPX 3400 machine.
Measurements of time response, intensity, and absorbance were carried out using a Deuterium-Tungsten DT-2-GS 30 light source and an Ocean Optics Flame spectrometer.
The biofunctionalization of the sensing area involved three sequential steps: 31 hydroxylation with a 0.
1M sodium hydroxide solution, salinization with a 2% (3-aminopropyl) triethoxysilane solution, and aldehyde 32 activation using a 2% glutaraldehyde solution.
The experiment used 120 ml of BSA solutions at concentrations of 31.
25 mg/dL, 62.
5 33 mg/dL, and 125 mg/dL.
Each method exhibits a unique spectral response across the ultraviolet, visible, and near-infrared regions.
Both 34 intensity and absorbance assessments reveal a significant reduction in sensitivity when transitioning from the cuvette to the tapered 35 optical fiber.
Notably, the sensitivity decreases by 99.
96% for intensity measurements and by 97.
76% for absorbance.
Nonetheless, after 36 biofunctionalization, the tapered optical fiber's sensitivity increased, showing a 207.
1% increase in absorbance and a 1494.
72% increase 37 in intensity measurements compared to the non-biofunctionalized tapered optical fiber.
Related Results
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract
Introduction
Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Precipitin Production in Chickens
Precipitin Production in Chickens
Summary
The antibody responses to simultaneous injection of varying concentrations (10, 20, 40 and 80 mg/kg body weight) of bovine serum albumin and human γ globulin...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Bovine serum albumin with gallic acid: Molecular modeling and physicochemical profiling
Bovine serum albumin with gallic acid: Molecular modeling and physicochemical profiling
Introduction. Gallic acid is a biologically active natural compound with strong antioxidant properties. Gallic acid is highly soluble and stable. It is known to increase the therma...
Optimization of Coiled Tubing (CT) Performance with the Use of Rapid Tapered Section
Optimization of Coiled Tubing (CT) Performance with the Use of Rapid Tapered Section
Abstract
The focus of this work is to optimize coiled tubing string design for greater horizontal reach in unconventional wells using a more rapidly tapered section ...
Tapered Optical Fiber Optofluidics: Bridging In-Fiber and Outside-Fiber Architectures Toward Autonomous Lab-on-Fiber Biosensing
Tapered Optical Fiber Optofluidics: Bridging In-Fiber and Outside-Fiber Architectures Toward Autonomous Lab-on-Fiber Biosensing
Optical fiber-based biosensors have proven to be a powerful platform for chemical and biological analysis due to their compact size, fast response, high sensitivity, and immunity t...
MAKALAH Penjasorkes “Aktivitas kebugaran jasmani”
MAKALAH Penjasorkes “Aktivitas kebugaran jasmani”
Puji syukur saya panjatkan kehadirat Tuhan Yang Maha Esa karena dengan rahmat, karunia, serta taufik dan hidayah-Nya lah saya dapat menyelesaikan makalah tentang “Aktivitas Kebugar...

