Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Dialysate Sodium: Rationale for Evolution over Time

View through CrossRef
AbstractOligo‐anuric individuals receiving hemodialysis (HD) are dependent on the dialysis machine to regulate sodium and water balance. Interest in adjusting the dialysate sodium concentration to promote tolerance of the HD procedure dates back to the early years of dialysis therapy. Evolution of dialysis equipment technologies and clinical characteristics of the dialysis population have prompted clinicians to increase the dialysate sodium concentration over time. Higher dialysate sodium concentrations generally promote hemodynamic stabilization and reduce intradialytic symptoms but often do so at the expense of stimulating thirst and promoting volume expansion. The opposite may be true for lower dialysate sodium concentrations. Observational data suggest that the association between dialysate sodium and outcomes may differ by serum sodium levels, supporting the trend toward individualization of the dialysate sodium prescription. However, lack of randomized controlled clinical trial data, along with operational safety concerns related to individualized dialysate sodium prescriptions, have prevented expert consensus regarding the optimal approach to the dialysate sodium prescription.
Title: Dialysate Sodium: Rationale for Evolution over Time
Description:
AbstractOligo‐anuric individuals receiving hemodialysis (HD) are dependent on the dialysis machine to regulate sodium and water balance.
Interest in adjusting the dialysate sodium concentration to promote tolerance of the HD procedure dates back to the early years of dialysis therapy.
Evolution of dialysis equipment technologies and clinical characteristics of the dialysis population have prompted clinicians to increase the dialysate sodium concentration over time.
Higher dialysate sodium concentrations generally promote hemodynamic stabilization and reduce intradialytic symptoms but often do so at the expense of stimulating thirst and promoting volume expansion.
The opposite may be true for lower dialysate sodium concentrations.
Observational data suggest that the association between dialysate sodium and outcomes may differ by serum sodium levels, supporting the trend toward individualization of the dialysate sodium prescription.
However, lack of randomized controlled clinical trial data, along with operational safety concerns related to individualized dialysate sodium prescriptions, have prevented expert consensus regarding the optimal approach to the dialysate sodium prescription.

Related Results

Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract Introduction Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...
Sodium Intake Markedly Alters Renal Interstitial Fluid Adenosine
Sodium Intake Markedly Alters Renal Interstitial Fluid Adenosine
AbstractAdenosine is produced locally in the kidney. Accumulating data suggest that adenosine plays a role in regulating renal functions. Using a microdialysis technique, we monito...
A STUDY ON DIALYSATE GLUCOSE CONCENTRATION IN PATIENTS WITH CONTINUOUS AMBULATORY PERITONEAL DIALYSIS
A STUDY ON DIALYSATE GLUCOSE CONCENTRATION IN PATIENTS WITH CONTINUOUS AMBULATORY PERITONEAL DIALYSIS
Background: Glucose-based peritoneal dialysis (PD) is the predominantly used dialysate in PD patients. Glucose absorption in peritoneal dialysis (PD) patients may contribute to adv...
Haemodialysis with low dialysate flow rates: A comparison of high performance membranes and conventional membranes
Haemodialysis with low dialysate flow rates: A comparison of high performance membranes and conventional membranes
Summary: We performed experimental studies to examine the effects of low dialysate flow rates on the clearance of small molecular weight substances, a middle molecular weight subs...
What is the Proper Composition of the Dialysate Magnesium and How Much Magnesium is Removed During Pre-Dilution Online Hemodiafiltration?
What is the Proper Composition of the Dialysate Magnesium and How Much Magnesium is Removed During Pre-Dilution Online Hemodiafiltration?
Aim: The aim of the study was to determine the ideal dialysate magnesium during hemodialysis, knowing that the solution used is not satisfactory and is often associated with low se...
Comparison of Two Different Kt/V Methods in Continuous Ambulatory Peritoneal Dialysis Patients
Comparison of Two Different Kt/V Methods in Continuous Ambulatory Peritoneal Dialysis Patients
Dialysis adequacy has gained particular interest for the assessment of the quality of dialysis in patients undergoing hemodialysis (HD) and continuous ambulatory peritoneal dialysi...
Could cooling dialysate improve inflammatory and nutritional status of hemodialysis patients?
Could cooling dialysate improve inflammatory and nutritional status of hemodialysis patients?
AbstractBackgroundIt has been shown that dialysate cooling (lowering the dialysate temperature to 0.5 °C below central body temperature) reduces the incidence of intradialytic hypo...
Pyruvate anions neutralize peritoneal dialysate cytotoxicity
Pyruvate anions neutralize peritoneal dialysate cytotoxicity
Abstract A new peritoneal dialysate containing pyruvate anions was developed in order to avoid cytotoxic effect of conventional lactate-based dialysate. The dialy...

Back to Top