Javascript must be enabled to continue!
Development of Normal‐Suction Boundary Control Method Based on Inflow Cannula Pressure Waveform for the Undulation Pump Ventricular Assist Device
View through CrossRef
AbstractIt is desirable to obtain the maximum assist without suction in ventricular assist devices (VADs). However, high driving power of a VAD may cause severe ventricle suction that can induce arrhythmia, hemolysis, and pump damage. In this report, an appropriate VAD driving level that maximizes the assist effect without severe systolic suction was explored. The target driving level was set at the boundary between low driving power without suction and high driving power with frequent suction. In the boundary range, intermittent mild suction may occur. Driving power was regulated by the suction occurrence. The normal‐suction boundary control method was evaluated in a female goat implanted with an undulation pump ventricular assist device (UPVAD). The UPVAD was driven in a semipulsatile mode with heartbeat synchronization control. Systolic driving power was adjusted using a normal‐suction boundary control method developed for this study. We confirmed that driving power could be maintained in the boundary range. Occurrences of suction were evaluated using the suction ratio. We defined this ratio as the number of suction occurrences divided by the number of heartbeats. The suction ratio decreased by 70% when the normal‐suction boundary control method was used.
Title: Development of Normal‐Suction Boundary Control Method Based on Inflow Cannula Pressure Waveform for the Undulation Pump Ventricular Assist Device
Description:
AbstractIt is desirable to obtain the maximum assist without suction in ventricular assist devices (VADs).
However, high driving power of a VAD may cause severe ventricle suction that can induce arrhythmia, hemolysis, and pump damage.
In this report, an appropriate VAD driving level that maximizes the assist effect without severe systolic suction was explored.
The target driving level was set at the boundary between low driving power without suction and high driving power with frequent suction.
In the boundary range, intermittent mild suction may occur.
Driving power was regulated by the suction occurrence.
The normal‐suction boundary control method was evaluated in a female goat implanted with an undulation pump ventricular assist device (UPVAD).
The UPVAD was driven in a semipulsatile mode with heartbeat synchronization control.
Systolic driving power was adjusted using a normal‐suction boundary control method developed for this study.
We confirmed that driving power could be maintained in the boundary range.
Occurrences of suction were evaluated using the suction ratio.
We defined this ratio as the number of suction occurrences divided by the number of heartbeats.
The suction ratio decreased by 70% when the normal‐suction boundary control method was used.
Related Results
Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system
Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system
Introduction: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system (“Dihead CPB”) for application during coronary artery bypass grafting (CABG) and valve su...
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Abstract
Flow instability is a common unsteady phenomenon in the field of turbomachinery that often causes large pressure fluctuations, performance penalties, and st...
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Suction Pile Allowable Suction Pressure Envelopes Based on Soil Failure and Structural Buckling
Suction Pile Allowable Suction Pressure Envelopes Based on Soil Failure and Structural Buckling
Abstract
This study develops the allowable suction pressure envelopes using applicable industrial codes for different suction pile sizes at various penetration depth...
Impact of Cannula Size on Clinical Outcomes in Peripheral Venoarterial Extracorporeal Membrane Oxygenation
Impact of Cannula Size on Clinical Outcomes in Peripheral Venoarterial Extracorporeal Membrane Oxygenation
Venoarterial extracorporeal membrane oxygenation (VA ECMO) is an effective mechanical circulatory support for cardiopulmonary failure. Conventionally, an arterial cannula over 15 F...
Analyzing Well Performance VII
Analyzing Well Performance VII
Introduction
Analyzing well performance is an important step toward increasing profits by improving production techniques. The analysis is made by field tests and...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract
The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
PROTOTYPE POMPA APUNG
PROTOTYPE POMPA APUNG
ABSTRACT
Floating pump is a water pump than can flat and adapt to the level of water surface. This water pump is solution of the problem happens because of the significant increas...