Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Preliminary investigation on performance of photodiode sensor as a dosimeter

View through CrossRef
Radiation dosimetry in the health and medicine field is crucial to ensure there is no unnecessary ionizing radiation exposure to patients and personnel. While various types of semiconductor dosimeters are available, photodiode sensors are seen as a reliable and cost-effective immediate dosimeter. This study investigates the capabilities of a monolithic photodiode with an on-chip trans-impedance amplifier as a dosimeter in diagnostic radiology. A photodiode sensor covered with black insulation tape is irradiated with the diagnostic x-ray of potential in range between 40 to 90 kV with constant tube current-time product of 50 mAs at 60 cm source-to-detector distance (SDD). Exposures of different tube current at the range of 10 to 250 mA with a constant tube voltage of 70 kVp at the same setup are made. The photodiode sensor connected to the electrometer gives out readings in the millivolt (mV), and the output of the photodiode and semiconductor detector is recorded. The photodiode’s energy dependency, reproducibility, dose response, and distance dependency were evaluated as the capabilities of the photodiode to be used as a dosimeter. For energy dependency, it shows a linearity of 0.9458, while the response to increasing tube current with a constant tube voltage shows the R2 of 0.912. The photodiode shows good dependency on the tube voltage and tube current. Other than that, it also showed a linear coefficient of 0.5138 for distance dependence which is considered as a good linearity fit value for a photodiode as initial performance. However, its reproducibility is poor due to its large capacitance. This monolithic photodiode with an on-chip trans-impedance amplifier has demonstrated good results for energy dependency but poor results for reproducibility. However, the photodiode can be improvised in the future to ensure it is suitable as a dosimeter.
Title: Preliminary investigation on performance of photodiode sensor as a dosimeter
Description:
Radiation dosimetry in the health and medicine field is crucial to ensure there is no unnecessary ionizing radiation exposure to patients and personnel.
While various types of semiconductor dosimeters are available, photodiode sensors are seen as a reliable and cost-effective immediate dosimeter.
This study investigates the capabilities of a monolithic photodiode with an on-chip trans-impedance amplifier as a dosimeter in diagnostic radiology.
A photodiode sensor covered with black insulation tape is irradiated with the diagnostic x-ray of potential in range between 40 to 90 kV with constant tube current-time product of 50 mAs at 60 cm source-to-detector distance (SDD).
Exposures of different tube current at the range of 10 to 250 mA with a constant tube voltage of 70 kVp at the same setup are made.
The photodiode sensor connected to the electrometer gives out readings in the millivolt (mV), and the output of the photodiode and semiconductor detector is recorded.
The photodiode’s energy dependency, reproducibility, dose response, and distance dependency were evaluated as the capabilities of the photodiode to be used as a dosimeter.
For energy dependency, it shows a linearity of 0.
9458, while the response to increasing tube current with a constant tube voltage shows the R2 of 0.
912.
The photodiode shows good dependency on the tube voltage and tube current.
Other than that, it also showed a linear coefficient of 0.
5138 for distance dependence which is considered as a good linearity fit value for a photodiode as initial performance.
However, its reproducibility is poor due to its large capacitance.
This monolithic photodiode with an on-chip trans-impedance amplifier has demonstrated good results for energy dependency but poor results for reproducibility.
However, the photodiode can be improvised in the future to ensure it is suitable as a dosimeter.

Related Results

Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
METHODS FOR IMPROVING THE DRG-05M DOSIMETER IN BRACHYTHERAPY
METHODS FOR IMPROVING THE DRG-05M DOSIMETER IN BRACHYTHERAPY
Relevance: The article discusses one of the ways to improve the DRG-05M dosimeter in brachytherapy by using new components and technologies in an improved scheme, which includes mo...
METHODS FOR IMPROVING THE DRG-05M DOSIMETER IN BRACHYTHERAPY
METHODS FOR IMPROVING THE DRG-05M DOSIMETER IN BRACHYTHERAPY
Relevance: The article discusses one of the ways to improve the DRG-05M dosimeter in brachytherapy by using new components and technologies in an improved scheme, which includes m...
Performance improvement of large area GaN MSM photodiode with thin AlGaN surface layer
Performance improvement of large area GaN MSM photodiode with thin AlGaN surface layer
PurposeThe purpose of this paper is to propose a new structure of GaN based metal‐semiconductor‐metal (MSM) photodiode, in which a thin unintentionally doped n‐type AlGaN layer is ...
Développement d'une photodiode à stockage de charges vertical pour les capteurs d'image CMOS éclairés par la face arrière
Développement d'une photodiode à stockage de charges vertical pour les capteurs d'image CMOS éclairés par la face arrière
L’augmentation continue de la résolution des capteurs d’image CMOS entraîne une réduction de la taille du pixel avec pour effet une diminution du nombre de charges stockables dans ...
Investigation of alanine dosimeter for output measurement in radiotherapy: Results from multicenter in Thailand
Investigation of alanine dosimeter for output measurement in radiotherapy: Results from multicenter in Thailand
Background: Alanine dosimeters are generally used in high-dose industrial applications (kGy). Later, research into employing alanine as a dosimeter in radiotherapy (1-20 Gy) has in...
Development of end-to-end test phantom for stereotactic radiosurgery using alanine dosimeter
Development of end-to-end test phantom for stereotactic radiosurgery using alanine dosimeter
Alanine dosimeters are generally used in high-dose dosimetry, while accurate and precise dose delivery verification procedures are important in stereotactic radiosurgery (SRS). Hen...
Effect of FBG Fiber Dosimeter Division in Sensing Capability for Low Radiation Doses
Effect of FBG Fiber Dosimeter Division in Sensing Capability for Low Radiation Doses
ر A fiber Bragg grating (FBG) as a dosimeter is developed in this simulation study (based on Optisystem 21 software) by dividing its region into five individual regions. The divis...