Javascript must be enabled to continue!
A COMPARATIVE STUDY OF MEDIUM-SIZED MACULAR HOLE SURGERY WITH INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE VERSUS CONVENTIONAL PEELING
View through CrossRef
Purpose:
To investigate surgical results for medium-sized (251–400 µm) macular holes (MHs).
Methods:
This retrospective observational study involved 266 eyes of 262 consecutive patients who underwent internal limiting membrane (ILM) peeling (147 eyes in the ILM peeling group) or inverted ILM flap cover technique (119 eyes in the inverted flap group) for primary medium-sized full-thickness MHs. Macular hole associated with retinal detachment, recurrent MH, and traumatic MH were excluded.
Results:
The primary closure rate for overall medium-sized MHs was 100% (119 of 119 eyes) in the inverted flap group, which was significantly higher than that (94.6% [139/147 eyes]; P = 0.010) in the ILM peeling group. Notably, even after adjusting for the minimum MH diameter, presence of high myopia, or preexisting posterior vitreous detachment, the primary closure rate was significantly better in the inverted flap group than in the ILM peeling group (Cochran–Mantel–Haenszel test, overall adjusted P = 0.006, 0.009, 0.005, respectively). The preoperative and postoperative restoration of the outer retinal layers and visual acuity were comparable between the inverted ILM flap and ILM peeling techniques.
Conclusion:
Primary closure for medium-sized MHs was significantly superior in the inverted flap group than in the ILM peeling group.
Ovid Technologies (Wolters Kluwer Health)
Title: A COMPARATIVE STUDY OF MEDIUM-SIZED MACULAR HOLE SURGERY WITH INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE VERSUS CONVENTIONAL PEELING
Description:
Purpose:
To investigate surgical results for medium-sized (251–400 µm) macular holes (MHs).
Methods:
This retrospective observational study involved 266 eyes of 262 consecutive patients who underwent internal limiting membrane (ILM) peeling (147 eyes in the ILM peeling group) or inverted ILM flap cover technique (119 eyes in the inverted flap group) for primary medium-sized full-thickness MHs.
Macular hole associated with retinal detachment, recurrent MH, and traumatic MH were excluded.
Results:
The primary closure rate for overall medium-sized MHs was 100% (119 of 119 eyes) in the inverted flap group, which was significantly higher than that (94.
6% [139/147 eyes]; P = 0.
010) in the ILM peeling group.
Notably, even after adjusting for the minimum MH diameter, presence of high myopia, or preexisting posterior vitreous detachment, the primary closure rate was significantly better in the inverted flap group than in the ILM peeling group (Cochran–Mantel–Haenszel test, overall adjusted P = 0.
006, 0.
009, 0.
005, respectively).
The preoperative and postoperative restoration of the outer retinal layers and visual acuity were comparable between the inverted ILM flap and ILM peeling techniques.
Conclusion:
Primary closure for medium-sized MHs was significantly superior in the inverted flap group than in the ILM peeling group.
Related Results
Korelasi Kadar Karboksihemoglobin terhadap Tekanan Darah Penduduk di Sekitar Terminal Bus Tirtonadi Surakarta
Korelasi Kadar Karboksihemoglobin terhadap Tekanan Darah Penduduk di Sekitar Terminal Bus Tirtonadi Surakarta
<table width="645" border="1" cellspacing="0" cellpadding="0"><tbody><tr><td valign="top" width="408"><p> </p><p>Carbon monoxide is a gas ...
Autologous Blood as Adjuvant in Inverted ILM Flap Surgery for Idiopathic Macular Hole: Case Series
Autologous Blood as Adjuvant in Inverted ILM Flap Surgery for Idiopathic Macular Hole: Case Series
Purpose:
To evaluate the use of autologous blood as an adjuvant in the surgical treatment of idiopathic macular hole (IMH) associated with the inverted internal...
Smartphone Augmented En-Face Guided Epiretinal Membrane Peeling: A 3D Ngenuity Tool For Customized Treatment
Smartphone Augmented En-Face Guided Epiretinal Membrane Peeling: A 3D Ngenuity Tool For Customized Treatment
Purpose:
We aimed to introduce a novel visualization technique of en-face scans during epiretinal membrane (ERM) peeling, by using the in-built picture-in-picture modal...
A Dynamic model of cutting cluster motion in carrot peeling machine
A Dynamic model of cutting cluster motion in carrot peeling machine
Carrot peeling machines incorporating multi-blade mechanisms arranged along a circular arc have been developed globally to meet growing market demands through high operational thro...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
Modified inverted internal limiting membrane flap technique for lamellar macular hole
Modified inverted internal limiting membrane flap technique for lamellar macular hole
Abstract
Background
Lamellar macular hole (LMH) is a partial-thickness macular defect thought to be caused by vitreofoveal traction, anteroposterior and tangential...
Prognostic Role of Optical Coherence Tomography in Outcome of Idiopathic full thickness Macular Hole Surgery
Prognostic Role of Optical Coherence Tomography in Outcome of Idiopathic full thickness Macular Hole Surgery
Abstract
Purpose: To assess the prognostic value of Optical Coherence Tomography indices preoperatively in outcome of idiopathic full thickness macular hole surgery.
Ma...

