MR‐guided ion therapy: Detector response in magnetic fields during carbon ion irradiation
View through CrossRef
AbstractBackgroundCombining carbon ion therapy with on‐bed MR imaging has the potential to bring particle therapy to a new level of precision. However, the introduction of magnetic fields brings challenges for dosimetry and quality assurance. For protons, a small, but significant change in detector response was shown in the presence of magnetic fields previously. For carbon ion beams, so far no such experiments have been performed.PurposeTo investigate the influence of external magnetic fields on the response of air‐filled ionization chambers.MethodsFour commercially available ionization chambers, three thimble type (Farmer, Semiflex, and PinPoint), and a plane parallel (Bragg peak) detector were investigated. Detectors were aligned in water such that their effective point of measurement was located at 2 cm depth. Irradiations were performed using square fields for carbon ions of 186.1, 272.5, and 402.8 MeV/u employing magnetic field strengths of 0, 0.25, 0.5, and 1 T. In addition, the detector response for protons and carbon ions was compared taking into account the secondary electron spectra and employing protons of 252.7 MeV for comparison.ResultsFor all four detectors, a statistically significant change in detector response, dependent on the magnetic field strength, was found. The effect was more pronounced for higher energies. The highest effects were found at 0.5 T for the PinPoint detector with a change in detector response of 1.1%. The response of different detector types appeared to be related to the cavity diameter. For proton and carbon ion irradiation with similar secondary electron spectra, the change in detector response was larger for carbon ions compared to protons.ConclusionA small, but significant dependence of the detector response was found for carbon ion irradiation in a magnetic field. The effect was found to be larger for smaller cavity diameters and at medium magnetic field strengths. Changes in detector response were more pronounced for carbon ions compared to protons.
Title: MR‐guided ion therapy: Detector response in magnetic fields during carbon ion irradiation
Description:
AbstractBackgroundCombining carbon ion therapy with on‐bed MR imaging has the potential to bring particle therapy to a new level of precision.
However, the introduction of magnetic fields brings challenges for dosimetry and quality assurance.
For protons, a small, but significant change in detector response was shown in the presence of magnetic fields previously.
For carbon ion beams, so far no such experiments have been performed.
PurposeTo investigate the influence of external magnetic fields on the response of air‐filled ionization chambers.
MethodsFour commercially available ionization chambers, three thimble type (Farmer, Semiflex, and PinPoint), and a plane parallel (Bragg peak) detector were investigated.
Detectors were aligned in water such that their effective point of measurement was located at 2 cm depth.
Irradiations were performed using square fields for carbon ions of 186.
1, 272.
5, and 402.
8 MeV/u employing magnetic field strengths of 0, 0.
25, 0.
5, and 1 T.
In addition, the detector response for protons and carbon ions was compared taking into account the secondary electron spectra and employing protons of 252.
7 MeV for comparison.
ResultsFor all four detectors, a statistically significant change in detector response, dependent on the magnetic field strength, was found.
The effect was more pronounced for higher energies.
The highest effects were found at 0.
5 T for the PinPoint detector with a change in detector response of 1.
1%.
The response of different detector types appeared to be related to the cavity diameter.
For proton and carbon ion irradiation with similar secondary electron spectra, the change in detector response was larger for carbon ions compared to protons.
ConclusionA small, but significant dependence of the detector response was found for carbon ion irradiation in a magnetic field.
The effect was found to be larger for smaller cavity diameters and at medium magnetic field strengths.
Changes in detector response were more pronounced for carbon ions compared to protons.
Related Results
Characterization of a novel HgCdTe focal plane array for ground and space astronomy through innovative infrared setups
Characterization of a novel HgCdTe focal plane array for ground and space astronomy through innovative infrared setups
(English) Nowadays, mercury-cadmium-telluride (MCT) short-wave infrared (SWIR) detectors are widely used in cutting-edge space
missions and ground-based telescopes. They take adva...
Conceptual design report of the MPD Cosmic Ray Detector (MCORD)
Conceptual design report of the MPD Cosmic Ray Detector (MCORD)
Abstract
This report presents a concept of constructing a detector
dedicated for detection of muons observed during measurements
carried out at the MPD (Multi-Pu...
Post-Irradiation Fracture Toughness Characterization of Generation II FeCrAl Alloys
Post-Irradiation Fracture Toughness Characterization of Generation II FeCrAl Alloys
Abstract
FeCrAl alloys are promising candidate materials for the accident tolerant fuel (ATF) cladding application due to their exceptional resistance to oxidation i...
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
In hypersonic flight, a very high temperature area can form ahead of the nose of aerocraft due to the shock aerodynamic heating, which leads to air weakly ionized. Many researchers...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Localized nanoscale induction by single domain magnetic particles
Localized nanoscale induction by single domain magnetic particles
AbstractSingle domain magnetic nanoparticles are increasingly investigated as actuators of biological and chemical processes that respond to externally applied magnetic fields. Alt...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Réponse du cerveau sain, des cellules souches neuronales et du glioblastome à une nouvelle technique de radiothérapie Flash
Réponse du cerveau sain, des cellules souches neuronales et du glioblastome à une nouvelle technique de radiothérapie Flash
De nos jours, plus de 50% des patients porteurs de tumeur bénéficient d’un traitement de radiothérapie. Malgré de récentes avancées technologiques augmentant de la précision des tr...