Javascript must be enabled to continue!
Corneal Morphological and Biomechanical Changes in Thyroid-Associated Ophthalmopathy
View through CrossRef
Purpose:
This study aimed to evaluate corneal morphological and biomechanical changes in patients with thyroid-associated ophthalmopathy (TAO) and their correlations with activity and severity.
Methods:
Patients diagnosed with TAO were recruited and divided into groups by activity and severity. All subjects underwent a complete ophthalmic examination, including magnetic resonance imaging. Corneal topography was measured using a Pentacam device, and biomechanical parameters were obtained using a CorVis ST tonometer. Correlations among the corneal parameters, clinical activity score, and NOSPECS score were analyzed. Areas under the receiver operating characteristic curves were calculated to evaluate the diagnostic accuracy of corneal changes for active and severe TAO.
Results:
Fifty-three eyes with TAO and 16 healthy eyes were enrolled in our study. The back elevation, CorVis biomechanical index, tomographic and biomechanical index, stiffness parameter at the first applanation, deviation from normality in back elevation, relational thickness, and overall deviation from normality were significantly increased in patients with TAO (all P <0.05), whereas the smallest corneal thickness, maximum Ambrósio relational thickness, and deformation amplitude (DA) ratio were significantly decreased (all P <0.05). The clinical activity score was strongly positively correlated with back elevation (γ = 0.515, P <0.001). The NOSPECS score was strongly positively correlated with relational thickness and tomographic and biomechanical index (γ = 0.429 and 0.515, P <0.001) and negatively correlated with maximum Ambrósio relational thickness (γ = −0.53, P <0.001). Moreover, maximum Ambrósio relational thickness and the Ambrósio relational thickness through the horizontal meridian showed desirable diagnostic capacity in distinguishing mild TAO from moderate-severe TAO (areas under the receiver operating characteristic curve, 0.799 and 0.769).
Conclusions:
Corneal morphological and biomechanical changes were found in patients with TAO, which might be related to the presence of inflammation. Measurements of corneal morphological and biomechanical parameters could serve as references in evaluating TAO.
Ovid Technologies (Wolters Kluwer Health)
Title: Corneal Morphological and Biomechanical Changes in Thyroid-Associated Ophthalmopathy
Description:
Purpose:
This study aimed to evaluate corneal morphological and biomechanical changes in patients with thyroid-associated ophthalmopathy (TAO) and their correlations with activity and severity.
Methods:
Patients diagnosed with TAO were recruited and divided into groups by activity and severity.
All subjects underwent a complete ophthalmic examination, including magnetic resonance imaging.
Corneal topography was measured using a Pentacam device, and biomechanical parameters were obtained using a CorVis ST tonometer.
Correlations among the corneal parameters, clinical activity score, and NOSPECS score were analyzed.
Areas under the receiver operating characteristic curves were calculated to evaluate the diagnostic accuracy of corneal changes for active and severe TAO.
Results:
Fifty-three eyes with TAO and 16 healthy eyes were enrolled in our study.
The back elevation, CorVis biomechanical index, tomographic and biomechanical index, stiffness parameter at the first applanation, deviation from normality in back elevation, relational thickness, and overall deviation from normality were significantly increased in patients with TAO (all P <0.
05), whereas the smallest corneal thickness, maximum Ambrósio relational thickness, and deformation amplitude (DA) ratio were significantly decreased (all P <0.
05).
The clinical activity score was strongly positively correlated with back elevation (γ = 0.
515, P <0.
001).
The NOSPECS score was strongly positively correlated with relational thickness and tomographic and biomechanical index (γ = 0.
429 and 0.
515, P <0.
001) and negatively correlated with maximum Ambrósio relational thickness (γ = −0.
53, P <0.
001).
Moreover, maximum Ambrósio relational thickness and the Ambrósio relational thickness through the horizontal meridian showed desirable diagnostic capacity in distinguishing mild TAO from moderate-severe TAO (areas under the receiver operating characteristic curve, 0.
799 and 0.
769).
Conclusions:
Corneal morphological and biomechanical changes were found in patients with TAO, which might be related to the presence of inflammation.
Measurements of corneal morphological and biomechanical parameters could serve as references in evaluating TAO.
Related Results
Primary Thyroid Non-Hodgkin B-Cell Lymphoma: A Case Series
Primary Thyroid Non-Hodgkin B-Cell Lymphoma: A Case Series
Abstract
Introduction
Non-Hodgkin lymphoma (NHL) of the thyroid, a rare malignancy linked to autoimmune disorders, is poorly understood in terms of its pathogenesis and treatment o...
Clinicopathological Features of Indeterminate Thyroid Nodules: A Single-center Cross-sectional Study
Clinicopathological Features of Indeterminate Thyroid Nodules: A Single-center Cross-sectional Study
Abstract
Introduction
Due to indeterminate cytology, Bethesda III is the most controversial category within the Bethesda System for Reporting Thyroid Cytopathology. This study exam...
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
A retrospective analysis of outcomes of an optical reconstructive surgery combined with corneal transplantation dedicated to manage complications of inflammatory diseases of the anterior chamber of the ey
A retrospective analysis of outcomes of an optical reconstructive surgery combined with corneal transplantation dedicated to manage complications of inflammatory diseases of the anterior chamber of the ey
Background: full thickness corneal transplantation or penetrating keratoplasty (PK) is the only surgical method to manage outcomes of
inflammatory diseases of the anterior eye cham...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
Relationship between serum NDRG3 and papillary thyroid carcinoma
Relationship between serum NDRG3 and papillary thyroid carcinoma
BackgroundIn recent years, papillary thyroid carcinoma is considered to be one of the fastest increaseing cancer. NDRG family member 3 (NDRG3) has been proposed as a molecular mark...
Molecular prognostication of thyroid tumors : with special focus on TERT
Molecular prognostication of thyroid tumors : with special focus on TERT
<p dir="ltr">Thyroid carcinoma is the most common endocrine malignancy, with its incidence steadily increasing worldwide. These tumors can be challenging to diagnose, and tre...
Molecular prognostication of thyroid tumors : with special focus on TERT
Molecular prognostication of thyroid tumors : with special focus on TERT
<p dir="ltr">Thyroid carcinoma is the most common endocrine malignancy, with its incidence steadily increasing worldwide. These tumors can be challenging to diagnose, and tre...