The Same-floor Drainage for Independent Retrofitting of the Existing Apartment Buildings without S-I System in China

View through CrossRef
Abstract By 1998 the total floor area of urban residential buildings was 9.59 billion square meters in China. In this period, most of the apartment buildings in China adopted brick-concrete structure or shear wall structure without SI-system, and limited the integrating means of retrofitting and reuse. Because of the strict control of area standard in urban residential construction at that time, the toilet area is always too small to carry the contemporary life style, which takes the first difficulty within independent retrofitting of the apartment building. Since the same-floor drainage system is widely used many new built apartment buildings, this paper aims to research and develop this system into retrofitting of the existing apartment buildings without S-I system in China. Based on the analysis to the household plans and their retrofitting design, two kinds of same-floor drainage systems are employed within the toilets, solve the problems of pipe connection, floor elevation and waterproof, and succeed to improve the function and space use of whole household.
Title: The Same-floor Drainage for Independent Retrofitting of the Existing Apartment Buildings without S-I System in China
Description:
Abstract By 1998 the total floor area of urban residential buildings was 9.
59 billion square meters in China.
In this period, most of the apartment buildings in China adopted brick-concrete structure or shear wall structure without SI-system, and limited the integrating means of retrofitting and reuse.
Because of the strict control of area standard in urban residential construction at that time, the toilet area is always too small to carry the contemporary life style, which takes the first difficulty within independent retrofitting of the apartment building.
Since the same-floor drainage system is widely used many new built apartment buildings, this paper aims to research and develop this system into retrofitting of the existing apartment buildings without S-I system in China.
Based on the analysis to the household plans and their retrofitting design, two kinds of same-floor drainage systems are employed within the toilets, solve the problems of pipe connection, floor elevation and waterproof, and succeed to improve the function and space use of whole household.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Sustainable Retrofitting of Existing Buildings: Techniques and Case Studies
Sustainable Retrofitting of Existing Buildings: Techniques and Case Studies
Retrofitting existing buildings for sustainability has become a critical endeavor in the quest for more energy-efficient and environmentally friendly built environments. This abstr...
(087) Why Should Pelvic Floor Physical Therapy be Included in Treatment of Vestibulodynia?
(087) Why Should Pelvic Floor Physical Therapy be Included in Treatment of Vestibulodynia?
Abstract Introduction Vestibulodynia, vulvar pain localized to the vestibule without an identifiable cause, has a multifactorial...
Der skal ikke lades sten på sten tilbage
Der skal ikke lades sten på sten tilbage
The Building by the Barbar TempleClose by the large temple at Barbar 1) lies a little tell, which was investigated in the spring of 1956. The tell was shown to cover a building of ...
Deep Retrofitting Study of Government Buildings in the UAE
Deep Retrofitting Study of Government Buildings in the UAE
This report summarizes the findings of a deep retrofitting modelling study of four government buildings across the UAE. Buildings envelope assessment, HVAC, and electrical systems ...
Doklam Standoff Resolution: Interview of Major General S B Asthana by SCMP
Doklam Standoff Resolution: Interview of Major General S B Asthana by SCMP
(Views of Major General S B Asthana,SM,VSM, (Veteran), Questioned by Jiangtao Shi of South China Morning Post on 29 August 2017.Question 1 (SCMP)Are you surprised that the over 70-...

Back to Top