Analysis and improvement of methods for calculating the resistance of substation earthing equipment

View through CrossRef
In this study, we analyze the results of calculating the resistance of substation earthing equipment taking operational factors into account. The resistance of a substation earthing system was estimated using both calculation (methods of equipment operating factors, generalized parameters and induced potentials) and instrumental (ammeter-voltmeter) methods. During operation, the resistance of the studied earthing system was found to increase in comparison with the rated values, thus reducing its overall efficiency. The resistance of substation earthing equipment measured experimentally by the ammeter-voltmeter method showed the relative error of the considered calculation methods to reach 48, 46.7 and 28.6%, respectively. With the purpose of increasing the calculation accuracy of earthing equipment resistance by the method of induced potentials, it was proposed to use an operating factor. Thus, during the substation operation period of 10, 10–20 and over 20 years, the resistance of the earthing system increases by 1.02–1.1 times due to corrosion. It was shown that the installation procedure and maintenance checks (conducted at least every six years) increase the resistance of earthing systems by 1.02 and 1.05 times, respectively. Lightning discharges and short-circuit currents affect the corrosion rate of earthing systems, thereby increasing their resistance by 1.01–1.03 and 1.03–1.05 times, respectively. Therefore, the operating factor value may range from 1.115 to 1.274. The use of the operating factor in calculating the resistance of an earthing system by the induced potentials method increased the overall calculation accuracy, with the relative error not exceeding 3%. This corresponds to the normative and technical requirements stipulated by the Federal Grid Company of the Unified Energy System of Russia.
Title: Analysis and improvement of methods for calculating the resistance of substation earthing equipment
Description:
In this study, we analyze the results of calculating the resistance of substation earthing equipment taking operational factors into account.
The resistance of a substation earthing system was estimated using both calculation (methods of equipment operating factors, generalized parameters and induced potentials) and instrumental (ammeter-voltmeter) methods.
During operation, the resistance of the studied earthing system was found to increase in comparison with the rated values, thus reducing its overall efficiency.
The resistance of substation earthing equipment measured experimentally by the ammeter-voltmeter method showed the relative error of the considered calculation methods to reach 48, 46.
7 and 28.
6%, respectively.
With the purpose of increasing the calculation accuracy of earthing equipment resistance by the method of induced potentials, it was proposed to use an operating factor.
Thus, during the substation operation period of 10, 10–20 and over 20 years, the resistance of the earthing system increases by 1.
02–1.
1 times due to corrosion.
It was shown that the installation procedure and maintenance checks (conducted at least every six years) increase the resistance of earthing systems by 1.
02 and 1.
05 times, respectively.
Lightning discharges and short-circuit currents affect the corrosion rate of earthing systems, thereby increasing their resistance by 1.
01–1.
03 and 1.
03–1.
05 times, respectively.
Therefore, the operating factor value may range from 1.
115 to 1.
274.
The use of the operating factor in calculating the resistance of an earthing system by the induced potentials method increased the overall calculation accuracy, with the relative error not exceeding 3%.
This corresponds to the normative and technical requirements stipulated by the Federal Grid Company of the Unified Energy System of Russia.

Related Results

Earthing as a Supportive Therapy for Post-Spinal Surgery Recovery
Earthing as a Supportive Therapy for Post-Spinal Surgery Recovery
Background/Objectives: Spinal surgery often results in injury to the paraspinal muscles and postoperative pain, which is associated with an elevated inflammatory response and incre...
DEVELOPMENT AND MODELLING OF HIGH SPREAD CONDUCTIVITY EARTH ELECTRODES FOR COMPLEX EARTHING ARRANGEMENTS
DEVELOPMENT AND MODELLING OF HIGH SPREAD CONDUCTIVITY EARTH ELECTRODES FOR COMPLEX EARTHING ARRANGEMENTS
The analysis of methods for calculating the electrical characteristics of earth electrodes in case of emergency currents of industrial frequency flowing through the elements of ear...
Reduced Susceptibility of Coronavirus SARS Development After Earthing Due to Increased pH Values in the Respiratory Tract
Reduced Susceptibility of Coronavirus SARS Development After Earthing Due to Increased pH Values in the Respiratory Tract
Abstract Background: Low pH is an important factor facilitating entry of enveloped viruses including coronaviruses and further fusion with the host epithelial cell membrane...
ANALISIS SISTEM PEMBUMIAN TOWER SALURAN TRANSMISI DARI GARDU INDUK KAPAL – GARDU INDUK GIANYAR
ANALISIS SISTEM PEMBUMIAN TOWER SALURAN TRANSMISI DARI GARDU INDUK KAPAL – GARDU INDUK GIANYAR
This study aims to improve the earthing value of transmission lines which have an earthvalue less than the standard value off SPLN No 121: 1996, namely 10 and recommend anearthing ...
Research on Key Technologies of Substation 3D Interactive Scene Simulation Based on Virtual Reality Technology
Research on Key Technologies of Substation 3D Interactive Scene Simulation Based on Virtual Reality Technology
Abstract The application of virtual reality technology in power industry training has become a new trend. The realization of substation virtual reality technology si...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract Introduction Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
FLOWER BUD REMOVAL AND EARTHING UP TIME INCREASED GROWTH AND TUBER YIELD OF POTATO AT EASTERN TIGRAY, ETHIOPIA
FLOWER BUD REMOVAL AND EARTHING UP TIME INCREASED GROWTH AND TUBER YIELD OF POTATO AT EASTERN TIGRAY, ETHIOPIA
<p class="abstrakinggris">In Ethiopia, potato is a staple food crop and source of cash income for smallholder farmers, but the national average yield in farmers’ field is low...
A research based on testing method for the whole substation cascaded in digital substation
A research based on testing method for the whole substation cascaded in digital substation
Substation as an important component of the power grid, its safe and steady operation is crucial to the power grid. After building new substation or renovating the old ones, they n...

Back to Top