Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

An Improved OPP Problem Formulation for Distribution Grid Observability

View through CrossRef
Phasor measurement units (PMUs) are becoming popular and populating the power system grids rapidly due to their wide range of benefits and applications. This research paper proposes a comprehensive, effective, and revised formulation of the optimal PMU placement (OPP) problem with a view to minimizing the required number of PMU and ensuring the maximum number of measurement redundancy subjected to the full observability of the distribution grids. The proposed formulation also incorporates the presence of passive measurements/zero injection buses (ZIB) and the channel availability of the installed PMU. Additionally, the formulation is extended to various contingency cases i.e., the single line outage and single PMU loss cases. This paper solves the proposed OPP formulation employing a heuristic technique called backtracking search algorithm (BSA) and tests its effectiveness through different IEEE standard distribution feeders. Additionally, this study compares the obtained results with the mixed integer linear programming (MILP)-based approach and the referenced works. The obtained results demonstrate the superiority of the proposed formulation and solution methodology compared to other methodologies.
Title: An Improved OPP Problem Formulation for Distribution Grid Observability
Description:
Phasor measurement units (PMUs) are becoming popular and populating the power system grids rapidly due to their wide range of benefits and applications.
This research paper proposes a comprehensive, effective, and revised formulation of the optimal PMU placement (OPP) problem with a view to minimizing the required number of PMU and ensuring the maximum number of measurement redundancy subjected to the full observability of the distribution grids.
The proposed formulation also incorporates the presence of passive measurements/zero injection buses (ZIB) and the channel availability of the installed PMU.
Additionally, the formulation is extended to various contingency cases i.
e.
, the single line outage and single PMU loss cases.
This paper solves the proposed OPP formulation employing a heuristic technique called backtracking search algorithm (BSA) and tests its effectiveness through different IEEE standard distribution feeders.
Additionally, this study compares the obtained results with the mixed integer linear programming (MILP)-based approach and the referenced works.
The obtained results demonstrate the superiority of the proposed formulation and solution methodology compared to other methodologies.

Related Results

KONTESTASI TASAWUF SUNNÎ DAN TASAWUF FALSAFÎ DI NUSANTARA
KONTESTASI TASAWUF SUNNÎ DAN TASAWUF FALSAFÎ DI NUSANTARA
<p>This article scrutinizes the history of Islamic development in Nusantara between 15th to 18th centuries, which has been colored from theological mysticism thought. Uniquel...
A CHINA E A TRANSIÇÃO SOCIALISTA – UM BREVE BOSQUEJO
A CHINA E A TRANSIÇÃO SOCIALISTA – UM BREVE BOSQUEJO
<!--[if gte mso 9]><xml> <o:DocumentProperties> <o:Revision>0</o:Revision> <o:TotalTime>0</o:TotalTime> <o:Pages>1</o:Pages> &...
Three Dimensional Simulations in Real Time for Personalized Drug Release Prosthesis Used in Lumbosacral Rehabilitation
Three Dimensional Simulations in Real Time for Personalized Drug Release Prosthesis Used in Lumbosacral Rehabilitation
This paper presents a theoretical method for simulation and three-dimensional reconstruction of the anatomical elements of the spine in order to achieve hydrogel disc prosthesis by...

Back to Top