Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of De-Noising Algorithms Technique

View through CrossRef
The concept of noise appears during the process of gathering the image into digital form: that is when the image is being created and it may also be introduced when the image is being transmitted. The presence of the noise usually degraded the quality of the image. De noising algorithms were employed in order to advance the value of the image. This paper tries to compare linear and non linear filtering algorithm. This study adopted image processing techniques to process 600 images dataset acquired from 60 different signers using vision based method. The acquired images were de-noised using Gaussian filter and Median filter algorithms. The outcomes of the two de-noising algorithms were compared using Peak Signal to Noise Ratio (PSNR) and Mean Square Error (MSE). The results of processed images for de-noising algorithms show that Median filter had higher PSNR of 47.7 than the Gaussian filter of 31.79, and lower MSE of 1.11 than Gaussian filter of 43.4.It was also ascertained that de-noised images with non-linear median filter had better quality than images de-noised by linear Gaussian filter.
Title: Comparison of De-Noising Algorithms Technique
Description:
The concept of noise appears during the process of gathering the image into digital form: that is when the image is being created and it may also be introduced when the image is being transmitted.
The presence of the noise usually degraded the quality of the image.
De noising algorithms were employed in order to advance the value of the image.
This paper tries to compare linear and non linear filtering algorithm.
This study adopted image processing techniques to process 600 images dataset acquired from 60 different signers using vision based method.
The acquired images were de-noised using Gaussian filter and Median filter algorithms.
The outcomes of the two de-noising algorithms were compared using Peak Signal to Noise Ratio (PSNR) and Mean Square Error (MSE).
The results of processed images for de-noising algorithms show that Median filter had higher PSNR of 47.
7 than the Gaussian filter of 31.
79, and lower MSE of 1.
11 than Gaussian filter of 43.
4.
It was also ascertained that de-noised images with non-linear median filter had better quality than images de-noised by linear Gaussian filter.

Related Results

Self-Supervised Electrocardiograph De-noising
Self-Supervised Electrocardiograph De-noising
Abstract The electrocardiogram (ECG) records heart-beats and is potentially life-saving. However, the ECG signals (e.g., recorded by the standard ECG monitoring sys...
Review Study of Image De-Noising on Digital Image Processing and Applications
Review Study of Image De-Noising on Digital Image Processing and Applications
This paper reviews several studies of image de-noising on digital image processing and applications. Noisy images contain different noise that exist either due to environment or el...
Noise Reduction of Electrocardiographic Signals using Wavelet Transforms
Noise Reduction of Electrocardiographic Signals using Wavelet Transforms
It has always been a critical issue to extract original signal having low signal-to-noise ratio (SNR) buried in heavy noise and interferences. Since the amplitude of the electrocar...
Gradient-based adaptive wavelet de-noising method for photoacoustic imaging in vivo
Gradient-based adaptive wavelet de-noising method for photoacoustic imaging in vivo
Photoacoustic imaging (PAI) has been applied to many biomedical applications over the past decades. However, the received PA signal usually suffers from poor signal-to-noise ratio ...
Bearing Fault Diagnosis Based on Wavelet Analysis
Bearing Fault Diagnosis Based on Wavelet Analysis
The de-noising principle using wavelet was discussed and the de-noising property was compared with that of using general threshold strategy. The steps of the per-level de-noising m...
Depth-prior-based lidar point cloud de-noising method leveraging range-gated imaging
Depth-prior-based lidar point cloud de-noising method leveraging range-gated imaging
Light Detection And Ranging (LiDAR) has been widely adopted to modern self-driving vehicles and mobile robotics, providing 3D information of the scene and surrounding objects. Howe...
Depth-prior-based lidar point cloud de-noising method leveraging range-gated imaging
Depth-prior-based lidar point cloud de-noising method leveraging range-gated imaging
Light Detection And Ranging (LiDAR) has been widely adopted to modern self-driving vehicles and mobile robotics, providing 3D information of the scene and surrounding objects. Howe...
ECG signal de-noising based on deep learning auto encoder and discrete wavelet transform
ECG signal de-noising based on deep learning auto encoder and discrete wavelet transform
ECG is very important tool for diagnosis of heart disease, this signal is suffered from different types of noises such as baseline wander (BW), muscle artifact (MA) and electrode m...

Back to Top