Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Application of Conformance Control Techniques in Tengiz Field

View through CrossRef
Abstract Sour Gas Injection project has been successfully implemented in Tengiz field, achieving long term pressure maintenance in the platform area by re-injecting gas with high H2S concentration and improving oil recovery. From the recent gas saturation campaign, sweep efficiency in injection pattern has varied from 10 to 70%, with the highest sweep, as well as most of gas breakthroughs observed in Bashkirian interval. This represents effective and uniform piston like miscible displacement across whole Bashkirian that enhances oil production. Similarly, surveillance monitoring shows that due to higher depletion rate in same Bashkirian, it experiences higher exposure to injectant fluid (sour gas) causing elevated GOR production at surface, whereas, lower intervals remain at near solution GOR with lower sweep efficiency. Such, anisotropy between the upper and lower intervals in terms of reservoir pressure and sweep efficiency creates an opportunity for the development of lower intervals by implementing conformance control technology. Injectant breakthrough and GOR elevation in SGI wells create additional challenges for TCO, due to limited gas handling capacity at the plant processing facilities. Hence, isolation of Bashkirian will not only stimulate lower intervals to produce, but also, reduce GOR concerns. First pilot workover to isolate Bashkirian in SGI used chemical polymers. Polymers were injected into the formation and provided strong isolation of the target interval. As a result, time-lapse gas saturation logs confirmed significant increase in vertical sweep efficiency across whole Unit-1 intervals, plus lower GOR production lasted for more than 6 years. Completion type variety in existing SGI wells, make application of chemical polymers challenging, therefore, conformance control completions were introduced as an alternative solution. Conformance control liner provides mechanical isolation between compartments for more effective staged acid stimulation treatments and enable potential isolation of unwanted fluids. This paper will introduce application of various conformance control techniques to alter production in SGI pattern by developing lower intervals and reducing elevated GOR. A gas shut-off campaign was initiated in Tengiz field after a decade of sour gas injection. Case studies will be presented to share challenges and results during planning and execution phases.
Title: Application of Conformance Control Techniques in Tengiz Field
Description:
Abstract Sour Gas Injection project has been successfully implemented in Tengiz field, achieving long term pressure maintenance in the platform area by re-injecting gas with high H2S concentration and improving oil recovery.
From the recent gas saturation campaign, sweep efficiency in injection pattern has varied from 10 to 70%, with the highest sweep, as well as most of gas breakthroughs observed in Bashkirian interval.
This represents effective and uniform piston like miscible displacement across whole Bashkirian that enhances oil production.
Similarly, surveillance monitoring shows that due to higher depletion rate in same Bashkirian, it experiences higher exposure to injectant fluid (sour gas) causing elevated GOR production at surface, whereas, lower intervals remain at near solution GOR with lower sweep efficiency.
Such, anisotropy between the upper and lower intervals in terms of reservoir pressure and sweep efficiency creates an opportunity for the development of lower intervals by implementing conformance control technology.
Injectant breakthrough and GOR elevation in SGI wells create additional challenges for TCO, due to limited gas handling capacity at the plant processing facilities.
Hence, isolation of Bashkirian will not only stimulate lower intervals to produce, but also, reduce GOR concerns.
First pilot workover to isolate Bashkirian in SGI used chemical polymers.
Polymers were injected into the formation and provided strong isolation of the target interval.
As a result, time-lapse gas saturation logs confirmed significant increase in vertical sweep efficiency across whole Unit-1 intervals, plus lower GOR production lasted for more than 6 years.
Completion type variety in existing SGI wells, make application of chemical polymers challenging, therefore, conformance control completions were introduced as an alternative solution.
Conformance control liner provides mechanical isolation between compartments for more effective staged acid stimulation treatments and enable potential isolation of unwanted fluids.
This paper will introduce application of various conformance control techniques to alter production in SGI pattern by developing lower intervals and reducing elevated GOR.
A gas shut-off campaign was initiated in Tengiz field after a decade of sour gas injection.
Case studies will be presented to share challenges and results during planning and execution phases.

Related Results

Conformance Control for Miscible CO2 Floods in Fractured Carbonates
Conformance Control for Miscible CO2 Floods in Fractured Carbonates
Abstract The application of miscible CO2 flooding for enhanced oil recovery in a vuggy/fractured carbonate formation has found commercial success in the Weyburn r...
IPM Tool for Strategic Decisions: Diverse Applications of IPM in the Supergiant Tengiz Field
IPM Tool for Strategic Decisions: Diverse Applications of IPM in the Supergiant Tengiz Field
Abstract Integrated Production Modeling (IPM) is probably the most popular suite of software for production optimization and planning. It affords the opportunity ...
Conformance Improvement Using Polymer Gels: A Case Study Approach
Conformance Improvement Using Polymer Gels: A Case Study Approach
Abstract Poor conformance is a problem that has plagued most operators of water and enhanced oil recovery (EOR) floods. Conformance improvement has been shown to sig...
Using Sized Calcium Carbonate (CaCO3) Particles in Mature CO2 EOR Projects for Deep Conformance
Using Sized Calcium Carbonate (CaCO3) Particles in Mature CO2 EOR Projects for Deep Conformance
Abstract Deep reservoir thief zone conformance has been one of the most challenging tasks in the oil industry for decades. The challenges are driven by finding a ...
A New Water Shut-Off Technology Using Sized Calcium Carbonate Particles in Safah Field, Oman
A New Water Shut-Off Technology Using Sized Calcium Carbonate Particles in Safah Field, Oman
Abstract Using Calcium Carbonate (CaCO3)to improve waterflood conformance is a new concept that was borrowed from drilling operations, in which sized CaCO3 particles...
Waterflood Conformance Improvement Method in Naturally Fractured Carbonate Reservoirs with Gel Injection
Waterflood Conformance Improvement Method in Naturally Fractured Carbonate Reservoirs with Gel Injection
The workflow for waterflood conformance improvement in a naturally fractured carbonate reservoir with polymer gel injection is presented. The workflow outlines a systematic way of ...
CONFORMANCE RATING FOR LOCOMOTIVE REPAIR PRODUCTIONS
CONFORMANCE RATING FOR LOCOMOTIVE REPAIR PRODUCTIONS
Purpose. Inspection and observation of the technical level of rail locomotive repair productions are conducted by the management team of the Department and the Locomotive division,...
Mature Fields Production Optimization Using Conformance Enhancement Gels.
Mature Fields Production Optimization Using Conformance Enhancement Gels.
Abstract Rigless operations for production optimization, well integrity, and reservoir management are the only practical options when firms are looking for ways to s...

Back to Top