Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Sphygmomanometer Dynamic Pressure Measurement Using a Condenser Microphone

View through CrossRef
There is a worldwide need to improve blood pressure (BP) measurement error in order to correctly diagnose hypertension. Cardiovascular diseases cause 17.9 million deaths annually and are a substantial monetary strain on healthcare. The current measurement uncertainty of 3 mmHg should be improved upon. Dynamic pressure measurement standards are lacking or non-existing. In this study we propose a novel method of measuring air pressure inside the sphygmomanometer tubing during BP measurement using a condenser microphone. We designed, built, and tested a system that uses a radiofrequency (RF) modulation method to convert changes in capacitance of a condenser microphone into pressure signals. We tested the RF microphone with a low-frequency (LF) sound source, BP simulator and using a piezoresistive pressure sensor as a reference. Necessary tests were conducted to assess the uncertainty budget of the system. The RF microphone prototype has a working frequency range from 0.5 Hz to 280 Hz in the pressure range from 0 to 300 mmHg. The total expanded uncertainty (k = 2, p = 95.5%) of the RF microphone was 4.32 mmHg. The proposed method could establish traceability of BP measuring devices to acoustic standards described in IEC 61094-2 and could also be used in forming dynamic BP standards.
Title: Sphygmomanometer Dynamic Pressure Measurement Using a Condenser Microphone
Description:
There is a worldwide need to improve blood pressure (BP) measurement error in order to correctly diagnose hypertension.
Cardiovascular diseases cause 17.
9 million deaths annually and are a substantial monetary strain on healthcare.
The current measurement uncertainty of 3 mmHg should be improved upon.
Dynamic pressure measurement standards are lacking or non-existing.
In this study we propose a novel method of measuring air pressure inside the sphygmomanometer tubing during BP measurement using a condenser microphone.
We designed, built, and tested a system that uses a radiofrequency (RF) modulation method to convert changes in capacitance of a condenser microphone into pressure signals.
We tested the RF microphone with a low-frequency (LF) sound source, BP simulator and using a piezoresistive pressure sensor as a reference.
Necessary tests were conducted to assess the uncertainty budget of the system.
The RF microphone prototype has a working frequency range from 0.
5 Hz to 280 Hz in the pressure range from 0 to 300 mmHg.
The total expanded uncertainty (k = 2, p = 95.
5%) of the RF microphone was 4.
32 mmHg.
The proposed method could establish traceability of BP measuring devices to acoustic standards described in IEC 61094-2 and could also be used in forming dynamic BP standards.

Related Results

Under-Sampled Microphone Data as a Wind Measurement
Under-Sampled Microphone Data as a Wind Measurement
It is common human experience that wind is associated with noise. Acoustic noise is generated by the turbulent pressure fluctuations  associated with the shearing flow near the gro...
Characterization of Micromachined Seesaw Type Microphone
Characterization of Micromachined Seesaw Type Microphone
A seesaw type microphone is characterized to study its feasibility for sound source localization. The microphone is composed of a flexible rectangular diaphragm sustained by two to...
Two-dimensional sound pressure distribution: Visualization and calibration-free quantification via optical wave microphone CT scanning
Two-dimensional sound pressure distribution: Visualization and calibration-free quantification via optical wave microphone CT scanning
In recent years, the optical wave microphone has emerged as an innovative technique, employing Fraunhofer diffraction of a laser beam, and shows promising applications in various a...
Extensions of Pressure Build-Up Analysis Methods
Extensions of Pressure Build-Up Analysis Methods
RUSSELL, D.G.,* MEMBER AIME, SHELL DEVELOPMENT CO., HOUSTON, TEX. Abstract Two techniques have been developed with which the app...
Research on Spacing Design Method of Condenser Half-Side Operation in Pressurized Water Reactor Nuclear Power Plant
Research on Spacing Design Method of Condenser Half-Side Operation in Pressurized Water Reactor Nuclear Power Plant
Abstract The condenser of Pressurized Water Reactor (PWR) nuclear power plant in China has many cooling tube leakage events, resulting in serious safety impact and e...
Analyzing Well Performance VII
Analyzing Well Performance VII
Introduction Analyzing well performance is an important step toward increasing profits by improving production techniques. The analysis is made by field tests and...
Research on Blood Pressure Monitoring Based on Flexible Encapsulated Sensors
Research on Blood Pressure Monitoring Based on Flexible Encapsulated Sensors
In order to realize the accurate measurement of wearable sphygmomanometer, this paper selects the micro electro mechanical system (MEMS) pressure sensor with small size, low cost a...

Back to Top