Javascript must be enabled to continue!
A New Symmetrical Source-Based DC/AC Converter with Experimental Verification
View through CrossRef
This research paper introduces a new topology for multilevel inverters, emphasizing the reduction of harmonic distortion and the optimization of the component count. The complexity of an inverter is determined by the number of power switches, which is significantly reduced in the presented topology, as fewer switches require fewer driver circuits. In this proposed topology, a new single-phase generalized multilevel inverter is analyzed with an equal magnitude of voltage supply. A 9-level, 11-level, or 13-level symmetrical inverter with RL load is analyzed in MATLAB/Simulink 2019b and then experimentally validated using the dSPACE-1103 controller. The experimental verification of the load voltage and current with different modulation indices is also presented. The analysis of the proposed topology concludes that the total required number of components is lower than that necessary for the classical inverter topologies, as well as for some new proposed multilevel inverters that are also compared with the proposed topology in terms of gate driver circuits, power switches, and DC sources, which thereby enhances the goodness of the proposed topology. Thus, a comparison of this inverter with the other topologies validates its acceptance.
Title: A New Symmetrical Source-Based DC/AC Converter with Experimental Verification
Description:
This research paper introduces a new topology for multilevel inverters, emphasizing the reduction of harmonic distortion and the optimization of the component count.
The complexity of an inverter is determined by the number of power switches, which is significantly reduced in the presented topology, as fewer switches require fewer driver circuits.
In this proposed topology, a new single-phase generalized multilevel inverter is analyzed with an equal magnitude of voltage supply.
A 9-level, 11-level, or 13-level symmetrical inverter with RL load is analyzed in MATLAB/Simulink 2019b and then experimentally validated using the dSPACE-1103 controller.
The experimental verification of the load voltage and current with different modulation indices is also presented.
The analysis of the proposed topology concludes that the total required number of components is lower than that necessary for the classical inverter topologies, as well as for some new proposed multilevel inverters that are also compared with the proposed topology in terms of gate driver circuits, power switches, and DC sources, which thereby enhances the goodness of the proposed topology.
Thus, a comparison of this inverter with the other topologies validates its acceptance.
Related Results
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Buck-boost Converter is the device with the function to convert DC Voltage input to the setpoint DC Voltage output. Buck-boost converter can be used for regulating unstable voltage...
Katalis Plat Kuningan Berbentuk Sarang Lebah untuk Mengurangi Emisi Kendaraan Bermotor
Katalis Plat Kuningan Berbentuk Sarang Lebah untuk Mengurangi Emisi Kendaraan Bermotor
Meningkatnya jumlah kendaraan bermotor berdampak langsung terhadap pencemaran udara akibat gas buang. Pencemaran udara di perkotaan didominasi oleh emisi kendaraan bermotor, disert...
Design of Buck Converter Based on Maximum Power Point Tracking for Photovoltaic Applications
Design of Buck Converter Based on Maximum Power Point Tracking for Photovoltaic Applications
e MPPT converter ensures that the PV system operates at the maximum power point, which is the point where the solar panels can generate the most power. This is done by adjusting th...
Shenzi 16-Inch Oil Export SCR CVA Verification
Shenzi 16-Inch Oil Export SCR CVA Verification
Abstract
In 2006 Enterprise developed a 16-inch oil export system from Shenzi field located in Green Canyon Block 653 in the Gulf of Mexico, approximately 120 nau...
Platform Verification - Aview From Amember Of Industry
Platform Verification - Aview From Amember Of Industry
ABSTRACT
Concerns have been raised in many sectors regarding the safety and reliability of offshore platforms. In this paper, the history of offshore operations a...
MORPHOLOGICAL FEATURES OF THE KIDNEYS OF DAY-OLD TURKEY CHICKS OF HYBRID CONVERTER AND HYBRID CONVERTER NOVO CROSSES
MORPHOLOGICAL FEATURES OF THE KIDNEYS OF DAY-OLD TURKEY CHICKS OF HYBRID CONVERTER AND HYBRID CONVERTER NOVO CROSSES
Kidneys of poultry, in particular turkeys, are poorly studied in terms of morphology and histology depending on age and cross. The aim of the study is to investigate the anatomical...
Computer Application in Converter Development from Concept to Manufacturing
Computer Application in Converter Development from Concept to Manufacturing
<div class="htmlview paragraph">Conventional catalytic converter developments driven by trial and error attempts by experts who successfully employ heuristics (a set of empir...
Simulation and Analysis of Dc-Dc Boost Converter Using Pspice SoftwareProgram
Simulation and Analysis of Dc-Dc Boost Converter Using Pspice SoftwareProgram
In many topologies and uses, the DC-DC converter has emerged as a crucial component. Electric cars, marine hoists, photovoltaic (PV) systems, uninterruptible power supply (UPS), an...

